Three-dimensional computed tomographic reconstruction using a C-arm mounted XRII: Image-based correction of gantry motion nonidealities

被引:102
|
作者
Fahrig, R
Holdsworth, DW
机构
[1] Univ Western Ontario, Dept Med Biophys & Diagnost Radiol, London, ON N6A 5K8, Canada
[2] John P Robarts Res Inst, London, ON N6A 5K8, Canada
关键词
x-ray image intensifier; calibration of geometric parameters; conebeam volume imaging;
D O I
10.1118/1.598854
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The image quality of 3D reconstructions produced using a C-arm mounted XRII depends on precise determination of the geometric parameters that describe the detector system in the laboratory frame of reference. We have designed a simplified calibration system that depends on images of a metal sphere, acquired during rotation of the gantry through 200 degrees. Angle-dependent shift corrections ore obtained, accounting for nonideal motion in two directions: perpendicular to the axis of rotation and tangential to the circular trajectory (tau), and parallel to the axis of rotation (xi). projection images are corrected prior to reconstruction using a simple shift-interpolation algorithm. We show that the motion of the gantry is highly reproducible during acquisitions within one day (mean standard deviation in tau and xi is 0.11 mm and 0.08 mml respectively), and over 21 months (mean standard deviation in tau and xi is 0.10 mm and 0.06 mm, respectively). Reconstruction of a small-bead phantom demonstrates uniformity of the correction algorithm over the full volume of the reconstruction [standard deviation of full-width-half-maximum of the beads is similar to 0.25 pixels (0.13 nm) over the volume of reconstruction]. Our approach provides a simple correction technique that can be applied when trajectory deviations are significant relative to the pixel size of the detector but small relative to the detector field of view, and when the fan angle of the acquisition geometry is small (<20 degrees). A comparison with other calibration techniques in the literature is provided. (C) 2000 American Institute of Physics.
引用
收藏
页码:30 / 38
页数:9
相关论文
共 50 条
  • [31] Comparison of Image-Based and Time-of-Flight-Based Technologies for Three-Dimensional Reconstruction of Infrastructure
    Dai, Fei
    Rashidi, Abbas
    Brilakis, Ioannis
    Vela, Patricio
    JOURNAL OF CONSTRUCTION ENGINEERING AND MANAGEMENT, 2013, 139 (01) : 69 - 79
  • [32] Image-based surface deformation for multi-view three-dimensional facial reconstruction
    Dong, Hongwei
    Dong, Shuhui
    IET COMPUTER VISION, 2014, 8 (06) : 498 - 509
  • [33] Estimation of Plants' Growth Parameters via Image-Based Reconstruction of Their Three-Dimensional Shape
    Lati, Ran Nisim
    Filin, Sagi
    Eizenberg, Hanan
    AGRONOMY JOURNAL, 2013, 105 (01) : 191 - 198
  • [34] A computational model of bounded developable surfaces with application to image-based three-dimensional reconstruction
    Perriollat, Mathieu
    Bartoli, Adrien
    COMPUTER ANIMATION AND VIRTUAL WORLDS, 2013, 24 (05) : 457 - 475
  • [35] Using a three-dimensional optical simulation to investigate uncertainty in image-based dimensional measurements
    Dong, Yue
    Hutchens, Thomas
    Mullany, Brigid
    Morse, Edward
    Davies, Angela
    OPTICAL ENGINEERING, 2014, 53 (09)
  • [36] Three-dimensional imaging on a vascular C-arm for percutaneous vertebroplasty procedures - Key factors impacting image quality
    Barral, FG
    Deramond, H
    Riddell, C
    Trousset, Y
    Benali, K
    RIVISTA DI NEURORADIOLOGIA, 2003, 16 (06): : 1377 - 1380
  • [37] Image-based crack assessment of bridge piers using unmanned aerial vehicles and three-dimensional scene reconstruction
    Liu, Yu-Fei
    Nie, Xin
    Fan, Jian-Sheng
    Liu, Xiao-Gang
    COMPUTER-AIDED CIVIL AND INFRASTRUCTURE ENGINEERING, 2020, 35 (05) : 511 - 529
  • [38] Use of a C-arm system to generate true three-dimensional computed rotational angiograms: Preliminary in vitro and in vivo results
    Fahrig, R
    Fox, AJ
    Lownie, S
    Holdsworth, DW
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1997, 18 (08) : 1507 - 1514
  • [39] Assessment of Normal Eyeball Protrusion Using Computed Tomographic Imaging and Three-Dimensional Reconstruction in Korean Adults
    Shin, Kang-Jae
    Gil, Young-Chun
    Lee, Shin-Hyo
    Kim, Jeong-Nam
    Yoo, Ja-Young
    Kim, Soon-Heum
    Choi, Hyun-Gon
    Shin, Hyun Jin
    Koh, Ki-Seok
    Song, Wu-Chul
    SEMINARS IN OPHTHALMOLOGY, 2017, 32 (05) : 575 - 581
  • [40] Three-dimensional image reconstruction for CCD camera based optical computed tomography scanner
    Thomas, Hannah Mary
    Devakumar, D.
    Ravindran, Paul B.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 2965 - +