Three-dimensional CT with a modified C-arm image intensifier: Feasibility

被引:88
|
作者
Linsenmaier, U
Rock, C
Euler, E
Wirth, S
Brandl, R
Kotsianos, D
Mutschler, W
Pfeifer, KJ
机构
[1] Univ Munich, Klinikum Univ Munchen Innenstadt, Dept Radiol, D-80336 Munich, Germany
[2] Univ Munich, Klinikum Univ Munchen Innenstadt, Dept Surg, D-80336 Munich, Germany
关键词
computed tomography (CT); technology; three-dimensional; extremities; CT;
D O I
10.1148/radiol.2241010646
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A portable C arm was modified for cone-beam computed tomography (CT). This three-dimensional (3D) CT imaging system facilitated the acquisition of fluoroscopic images during a 190degrees rotation and computed a 3D data cube (matrix, 256 X 256 X 256; scanning time, 100 seconds) with multiplanar image reformation. The high-contrast resolution, 0.9 line pairs per millimeter, was comparable; the low-contrast resolution, minimal; and the radiation dose, 600/6-80% lower, as compared with these parameters at spiral CT. The normal anatomy of small joints could be depicted, and the osteosynthesis screws in the talus were correctly identified. (C) RSNA, 2002.
引用
收藏
页码:286 / 292
页数:7
相关论文
共 50 条
  • [1] Three-dimensional reconstruction of high contrast objects using C-arm image intensifier projection data
    Grass, M
    Koppe, R
    Klotz, E
    Proksa, R
    Kuhn, MH
    Aerts, H
    Op de Beek, J
    Kemkers, R
    [J]. COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1999, 23 (06) : 311 - 321
  • [2] Three-dimensional computed tomographic reconstruction using a C-arm mounted XRII: Correction of image intensifier distortion
    Fahrig, R
    Moreau, M
    Holdsworth, DW
    [J]. MEDICAL PHYSICS, 1997, 24 (07) : 1097 - 1106
  • [3] The tent drape for the C-arm image intensifier
    Al-Shawi, AK
    Fern, ED
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2004, 35 (09): : 927 - 929
  • [4] Feasibility of a new C-arm Angiography (DYNA-CT) based three-dimensional Coronary Reconstruction Algorithm
    Rittger, Harald
    Rieber, Johannes
    Sinha, Anil
    Schmidt, Martin
    Brachmann, Johannes
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2009, 104 (6A): : 164D - 165D
  • [5] Three-dimensional CT angiography from a clinical C-arm mounted XRII
    Fahrig, R
    Fox, AJ
    Holdsworth, DW
    [J]. RADIOLOGY, 1996, 201 : 879 - 879
  • [6] Sparsity-constrained three-dimensional image reconstruction for C-arm angiography
    Rashed, Essam A.
    al-Shatouri, Mohammad
    Kudo, Hiroyuki
    [J]. COMPUTERS IN BIOLOGY AND MEDICINE, 2015, 62 : 141 - 153
  • [7] Three-dimensional C-arm cone-beam CT: Applications in the interventional suite
    Wallace, Michael J.
    Kuo, Michael D.
    Glaiberman, Craig
    Binkert, Christoph A.
    Orth, Robert C.
    Soulez, Gilles
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2008, 19 (06) : 799 - 813
  • [8] Potential role of three-dimensional rotational angiography and C-arm CT for valvular repair and implantation
    Schwartz, Jonathan G.
    Neubauer, Anne M.
    Fagan, Thomas E.
    Noordhoek, Niels J.
    Grass, Michael
    Carroll, John D.
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2011, 27 (08): : 1205 - 1222
  • [9] Potential role of three-dimensional rotational angiography and C-arm CT for valvular repair and implantation
    Jonathan G. Schwartz
    Anne M. Neubauer
    Thomas E. Fagan
    Niels J. Noordhoek
    Michael Grass
    John D. Carroll
    [J]. The International Journal of Cardiovascular Imaging, 2011, 27 : 1205 - 1222
  • [10] Effect of introduction of mini C-arm image intensifier in orthopaedic theatre
    White, S. P.
    [J]. ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2007, 89 (03) : 268 - 271