Compressed-sensing-based three-dimensional image reconstruction algorithm for C-arm vascular imaging

被引:0
|
作者
Selim, Mona [1 ,4 ]
al-Shatouri, Mohammad [2 ]
Kudo, Hiroyuki [3 ]
Rashed, Essam A. [4 ]
机构
[1] Suez Univ, Fac Sci, Math & Comp Sci Dept, Suez, Egypt
[2] Suez Canal Univ, Dept Radiol, Fac Med, Ismailia, Egypt
[3] Univ Tsukuba, Dept Comp Sci, Tsukuba, Ibaraki, Japan
[4] Suez Canal Univ, Dept Math, Image Sci Lab, Fac Sci, Ismailia, Egypt
关键词
Image reconstruction; computed tomography; 3D C-arm CT; ADMM; PROJECTIONS; DETECTOR;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
X-ray C-arm is an important imaging tool in interventional surgery, road-mapping and radiation therapy. It provides accurate description of vascular anatomy and therapy end point. The C-arm scanner produces two-dimensional (2D) x-ray projection data obtained with flat-panel detector by rotating the source around the patient. The number of 2D projections acquired is several hundreds, which results in significant amount of radiation dose. Unlike the conventional fluoroscopic imaging, three-dimensional (3D) C-arm computed tomography (CT) provides more accurate cross-sectional images which are valuable for therapy planning, guidance and evaluation in interventional radiology. However, 3D vascular imaging using the conventional C-arm fluoroscopy is a challenging task. First, the rotation orbit of the C-arm gantry is usually limited to a range less than those of CT scanners. Second, in several commercial models (including the one of consideration in this study), the x-ray source and detector are shifted from the gantry isocenter to enlarge the scanner field-of-view (FOV), which is so-called the offset scan. Finally, it is difficult to acquire sufficient projection views required for stable 3D reconstruction using manually controlled gantry motion. Inspired by the theory of compressed sensing, we developed an image reconstruction algorithm for the conventional angiography C-arm scanners. The main challenge in this image reconstruction problem is the projection data limitations. We consider a small number of views (less than 10 views) acquired from a short orbit with the offset scan geometry. The proposed method is developed using the alternating direction method of multipliers (ADMM) and results obtained from simulated data and real data are encouraging. The proposed method can significantly contribute to the reduction of patient dose and provides a framework to generate 3D vascular images using the conventional C-arm scanners.
引用
收藏
页码:111 / 114
页数:4
相关论文
共 50 条
  • [1] Sparsity-constrained three-dimensional image reconstruction for C-arm angiography
    Rashed, Essam A.
    al-Shatouri, Mohammad
    Kudo, Hiroyuki
    [J]. COMPUTERS IN BIOLOGY AND MEDICINE, 2015, 62 : 141 - 153
  • [2] Clinical interest in three-dimensional imaging on a vascular C-arm for percutaneous vertebroplasty
    Deramond, H
    Barral, FG
    Trousset, Y
    Riddell, C
    Benali, K
    [J]. RIVISTA DI NEURORADIOLOGIA, 2003, 16 (06): : 1373 - 1376
  • [3] Compressed-Sensing-based Gradient Reconstruction for Ghost Imaging
    Zhu, Rong
    Li, Guangshun
    Guo, Ying
    [J]. INTERNATIONAL JOURNAL OF THEORETICAL PHYSICS, 2019, 58 (04) : 1215 - 1226
  • [4] Compressed-Sensing-based Gradient Reconstruction for Ghost Imaging
    Rong Zhu
    Guangshun Li
    Ying Guo
    [J]. International Journal of Theoretical Physics, 2019, 58 : 1215 - 1226
  • [5] Compressed-sensing-based content-driven hierarchical reconstruction: Theory and application to C-arm cone-beam tomography
    Langet, Helene
    Riddell, Cyril
    Reshef, Aymeric
    Trousset, Yves
    Tenenhaus, Arthur
    Lahalle, Elisabeth
    Fleury, Gilles
    Paragios, Nikos
    [J]. MEDICAL PHYSICS, 2015, 42 (09) : 5222 - 5237
  • [6] Three-dimensional imaging on a vascular C-arm for percutaneous vertebroplasty procedures - Key factors impacting image quality
    Barral, FG
    Deramond, H
    Riddell, C
    Trousset, Y
    Benali, K
    [J]. RIVISTA DI NEURORADIOLOGIA, 2003, 16 (06): : 1377 - 1380
  • [7] Feasibility of a new C-arm Angiography (DYNA-CT) based three-dimensional Coronary Reconstruction Algorithm
    Rittger, Harald
    Rieber, Johannes
    Sinha, Anil
    Schmidt, Martin
    Brachmann, Johannes
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2009, 104 (6A): : 164D - 165D
  • [8] Three-dimensional CT with a modified C-arm image intensifier: Feasibility
    Linsenmaier, U
    Rock, C
    Euler, E
    Wirth, S
    Brandl, R
    Kotsianos, D
    Mutschler, W
    Pfeifer, KJ
    [J]. RADIOLOGY, 2002, 224 (01) : 286 - 292
  • [9] Multiscale wavelet-based regularized reconstruction algorithm for three-dimensional compressed sensing magnetic resonance imaging
    Islam, Md Shafiqul
    Islam, Rafiqul
    [J]. SIGNAL IMAGE AND VIDEO PROCESSING, 2021, 15 (07) : 1487 - 1495
  • [10] Multiscale wavelet-based regularized reconstruction algorithm for three-dimensional compressed sensing magnetic resonance imaging
    Md. Shafiqul Islam
    Rafiqul Islam
    [J]. Signal, Image and Video Processing, 2021, 15 : 1487 - 1495