Novel x-ray source for dual-energy subtraction angiography

被引:6
|
作者
Tuffanelli, A [1 ]
Taibi, A [1 ]
Baldazzi, G [1 ]
Bollini, D [1 ]
Gombia, M [1 ]
Ramello, L [1 ]
Gambaccini, M [1 ]
机构
[1] Univ Ferrara, Dipartimento Fis, I-44100 Ferrara, Italy
关键词
digital subtraction angiography; dual energy angiography; tungsten anode x-ray tube; dichromatic x-ray beams; Bragg diffraction; mosaic crystal;
D O I
10.1117/12.465572
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In angiography practice an iodate contrast medium is injected in patient vessels with catheters. The absorption of x-rays raises immediately after the iodine K-edge energy (33.17 keV). In digital subtraction angiography, two images are used, acquired before and after the injection of the contrast medium, respectively. The vessels morphology results from the difference of images so obtained. This technique involves a non-negligible risk of morbidity or mortality, due to high concentration of injected contrast agent. We are investigating a new source which produces two thin parallel quasi-monochromatic beams - having peak energies centered before and after the iodine K-edge energy, respectively - by using a conventional x-ray tube and a highly oriented pyrolytic graphite mosaic crystal. The polychromatic x-rays incident on the crystal are monochromatized by Bragg diffraction and splitted in two thin parallel beams, by means of a collimating system. These two beams impinge on the phantom simulating patient vessels and are detected with solid-state array detectors. The image results as difference between the remaining intensities of two beams. We report a preliminary study of the new technique performed both with theoretical simulations and experimental measurements. Results of computer simulation give information about characteristics as size and quality of the quasi-monochromatic beams, that should be considered in detail to design a system dedicated to the clinical practice. Experimental measurements have been performed on a small-field detector in order to shows the enhancement of image contrast obtained with the application of the new technique.
引用
收藏
页码:311 / 319
页数:5
相关论文
共 50 条
  • [1] Theoretical and experimental comparison of image signal and noise for dual-energy subtraction angiography and conventional x-ray angiography
    Burton, Christiane S.
    Mayo, John R.
    Cunningham, Ian A.
    [J]. MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [2] First results with a novel X-ray source for dual energy angiography
    Baldazzi, G
    Bollini, D
    Celesti, E
    Gambaccini, M
    Gombia, M
    Labanti, C
    Taibi, A
    Tuffanelli, A
    [J]. 2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 1615 - 1619
  • [3] Realization of one-shot dual-energy X-ray subtraction in general X-ray equipment
    Ying, L
    Xu, LS
    [J]. IEEE-EMBS ASIA PACIFIC CONFERENCE ON BIOMEDICAL ENGINEERING - PROCEEDINGS, PTS 1 & 2, 2000, : 497 - 498
  • [4] Dual-energy X-ray CT by Compton scattering hard X-ray source
    Kaneyasu, T
    Uesaka, N
    Dobashi, K
    Torikoshi, M
    [J]. 2005 IEEE PARTICLE ACCELERATOR CONFERENCE (PAC), VOLS 1-4, 2005, : 1680 - 1682
  • [5] Lung field segmenting in dual-energy subtraction chest x-ray images
    Alvarez, RE
    [J]. JOURNAL OF DIGITAL IMAGING, 2004, 17 (01) : 45 - 56
  • [6] Lung Field Segmenting in Dual-Energy Subtraction Chest X-ray Images
    Robert E. Alvarez
    [J]. Journal of Digital Imaging, 2004, 17 : 45 - 56
  • [7] Signal-difference-to-noise comparison of temporal subtraction, kV-switching dual-energy and photon-counting dual-energy x-ray angiography
    Aubert, Sarah
    Tanguay, Jesse
    [J]. MEDICAL PHYSICS, 2023, 50 (12) : 7400 - 7414
  • [8] Dual-energy X-ray absorptiometry
    Braillon, Pierre
    Peretti, Noel
    [J]. NUTRITION CLINIQUE ET METABOLISME, 2011, 25 (02): : 91 - 96
  • [9] Dual-energy X-ray Absorptiometry
    Jain, Rajesh K.
    Vokes, Tamara
    [J]. JOURNAL OF CLINICAL DENSITOMETRY, 2017, 20 (03) : 291 - 303
  • [10] Dual-energy X-ray diagnostics
    Coumans, J.J.H.
    [J]. Philips Technical Review, 1986, 42 (8-9): : 274 - 285