Novel x-ray source for dual-energy subtraction angiography

被引:6
|
作者
Tuffanelli, A [1 ]
Taibi, A [1 ]
Baldazzi, G [1 ]
Bollini, D [1 ]
Gombia, M [1 ]
Ramello, L [1 ]
Gambaccini, M [1 ]
机构
[1] Univ Ferrara, Dipartimento Fis, I-44100 Ferrara, Italy
关键词
digital subtraction angiography; dual energy angiography; tungsten anode x-ray tube; dichromatic x-ray beams; Bragg diffraction; mosaic crystal;
D O I
10.1117/12.465572
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In angiography practice an iodate contrast medium is injected in patient vessels with catheters. The absorption of x-rays raises immediately after the iodine K-edge energy (33.17 keV). In digital subtraction angiography, two images are used, acquired before and after the injection of the contrast medium, respectively. The vessels morphology results from the difference of images so obtained. This technique involves a non-negligible risk of morbidity or mortality, due to high concentration of injected contrast agent. We are investigating a new source which produces two thin parallel quasi-monochromatic beams - having peak energies centered before and after the iodine K-edge energy, respectively - by using a conventional x-ray tube and a highly oriented pyrolytic graphite mosaic crystal. The polychromatic x-rays incident on the crystal are monochromatized by Bragg diffraction and splitted in two thin parallel beams, by means of a collimating system. These two beams impinge on the phantom simulating patient vessels and are detected with solid-state array detectors. The image results as difference between the remaining intensities of two beams. We report a preliminary study of the new technique performed both with theoretical simulations and experimental measurements. Results of computer simulation give information about characteristics as size and quality of the quasi-monochromatic beams, that should be considered in detail to design a system dedicated to the clinical practice. Experimental measurements have been performed on a small-field detector in order to shows the enhancement of image contrast obtained with the application of the new technique.
引用
收藏
页码:311 / 319
页数:5
相关论文
共 50 条
  • [21] Dual-energy x-ray absorptiometry in osteopetrosis
    Adler, IN
    Stine, KC
    Kurtzburg, J
    Kinder, DL
    Cox, KS
    Lensing, SY
    Seibert, JJ
    SOUTHERN MEDICAL JOURNAL, 2000, 93 (05) : 501 - 503
  • [22] Embossed x-ray computed tomography utilizing pixel-shifted dual-energy subtraction
    Ito, Kazuki
    Sato, Eiichi
    Oda, Yasuyuki
    Moriyama, Hodaka
    Hagiwara, Osahiko
    Enomoto, Toshiyuki
    Yoshida, Sohei
    Watanabe, Manabu
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2024, 95 (07):
  • [23] CCD camera for dual-energy digital subtraction angiography
    Molloi, S
    Ersahin, A
    Qian, YJ
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1995, 14 (04) : 747 - 752
  • [24] Prototype system for interventional dual-energy subtraction angiography
    Speidel, Michael A.
    Burton, Christiane S.
    Nikolau, Ethan P.
    Schafer, Sebastian
    Laeseke, Paul F.
    MEDICAL IMAGING 2019: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2019, 10951
  • [25] THE APPLICATION OF X-RAY PHOSPHORS IN DUAL ENERGY SUBTRACTION
    HO, JT
    KRUGER, RA
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1988, 135 (08) : C389 - C389
  • [26] A K-ALPHA DUAL ENERGY X-RAY SOURCE FOR CORONARY ANGIOGRAPHY
    MANNING, HL
    SHEFER, RE
    KLINKOWSTEIN, RE
    MISTRETTA, CA
    MEDICAL PHYSICS, 1991, 18 (05) : 880 - 893
  • [27] Inverse Compton radiation: a novel x-ray source for K-edge subtraction angiography?
    Paterno, G.
    Cardarelli, P.
    Gambaccini, M.
    Serafini, L.
    Petrillo, V
    Drebot, I
    Taibi, A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (18):
  • [28] Dual-energy CBCT by Spectral Filtration of a Dual-focus CNT X-ray Source
    Li, Boyuan
    Hu, Yuanming
    Inscoe, Christina R.
    Xu, Shuang
    Tyndall, Donald A.
    Lee, Yueh Z.
    Lu, Jianping
    Zhou, Otto
    MEDICAL IMAGING 2024: PHYSICS OF MEDICAL IMAGING, PT 1, 2024, 12925
  • [29] X-Ray Spectra Optimization for Dual-Energy Imaging Using Dual-Source CT
    Giraldo, J. Ramirez
    Primak, A.
    Liu, X.
    McCollough, C.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [30] Experimental and theoretical studies of dual energy subtraction angiography (DESA) performed using laser-based x-ray source
    Krol, A
    Kieffer, JC
    Ichalaleb, Z
    Jiang, ZM
    Chamberlain, CC
    Scalzetti, E
    APPLICATIONS OF X RAYS GENERATED FROM LASERS AND OTHER BRIGHT SOURCES II, 2001, 4504 : 227 - 233