摘要
The purpose of this study was to develop and test a method to delineate lung field boundaries in dual-energy chest x-ray images. The segmenting method uses soft-tissue images and spatial frequency-dependent, background-subtracted images. Large-scale chest anatomy features are located and used to select the lung apices, the lateral lung boundaries, and the lung-mediastinum and lung-diaphragm boundaries. Extraneous parts of the contours are removed and they are joined to form complete lung boundaries. The reliability measure uses a statistical shape model to estimate the probability of occurrence of a contour. The method was experimentally tested with 30 human subject images. It has higher accuracy and specificity and a sensitivity parameter equal to the best previously reported method. The reliability measure is able to detect contours with unusual lung outlines or errors in the processing. The method exploits the characteristics of dual-energy subtraction images to improve lung field segmenting performance.
引用
收藏
页码:45 / 56
页数:12
相关论文
共 50 条
  • [1] Lung Field Segmenting in Dual-Energy Subtraction Chest X-ray Images
    Robert E. Alvarez
    Journal of Digital Imaging, 2004, 17 : 45 - 56
  • [2] Novel x-ray source for dual-energy subtraction angiography
    Tuffanelli, A
    Taibi, A
    Baldazzi, G
    Bollini, D
    Gombia, M
    Ramello, L
    Gambaccini, M
    MEDICAL IMAGING 2002: PHYSICS OF MEDICAL IMAGING, 2002, 4682 : 311 - 319
  • [3] Development of a deep neural network for generating synthetic dual-energy chest x-ray images with single x-ray exposure
    Lee, Donghoon
    Kim, Hwiyoung
    Choi, Byungwook
    Kim, Hee-Joung
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (11):
  • [4] Realization of one-shot dual-energy X-ray subtraction in general X-ray equipment
    Ying, L
    Xu, LS
    IEEE-EMBS ASIA PACIFIC CONFERENCE ON BIOMEDICAL ENGINEERING - PROCEEDINGS, PTS 1 & 2, 2000, : 497 - 498
  • [5] Dual-energy X-ray absorptiometry
    Braillon, Pierre
    Peretti, Noel
    NUTRITION CLINIQUE ET METABOLISME, 2011, 25 (02): : 91 - 96
  • [6] Dual-energy X-ray Absorptiometry
    Jain, Rajesh K.
    Vokes, Tamara
    JOURNAL OF CLINICAL DENSITOMETRY, 2017, 20 (03) : 291 - 303
  • [7] Dual-energy X-ray diagnostics
    Coumans, J.J.H.
    Philips Technical Review, 1986, 42 (8-9): : 274 - 285
  • [8] Enhancement of Lung Tumor Visibility by Dual-Energy X-Ray Imaging in An Anthropomorphic Chest Phantom Study
    Menten, Mj
    Fast, M. F.
    Nill, S.
    Oelfke, U.
    MEDICAL PHYSICS, 2014, 41 (06) : 510 - 510
  • [9] A Novel Hybrid Framework to Enhance Dual-Energy X-Ray Images
    Ullah, Burhan
    Khan, Aurangzeb
    Shah, Said Khalid
    Su'ud, Mazliham Mohd
    Alam, Muhammad Mansoor
    Alam, Mahmood
    JOURNAL OF SENSORS, 2023, 2023
  • [10] Illicit Material Detection using Dual-Energy X-Ray Images
    Hassanpour, Reza
    International Arab Journal of Information Technology, 2016, 13 (04) : 409 - 416