Lung field segmenting in dual-energy subtraction chest x-ray images

被引:8
|
作者
Alvarez, RE [1 ]
机构
[1] Aprend Technol, Mountain View, CA 94043 USA
关键词
lung; segmenting; dual-energy subtraction; chest; x-ray;
D O I
10.1007/s10278-003-1701-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to develop and test a method to delineate lung field boundaries in dual-energy chest x-ray images. The segmenting method uses soft-tissue images and spatial frequency-dependent, background-subtracted images. Large-scale chest anatomy features are located and used to select the lung apices, the lateral lung boundaries, and the lung-mediastinum and lung-diaphragm boundaries. Extraneous parts of the contours are removed and they are joined to form complete lung boundaries. The reliability measure uses a statistical shape model to estimate the probability of occurrence of a contour. The method was experimentally tested with 30 human subject images. It has higher accuracy and specificity and a sensitivity parameter equal to the best previously reported method. The reliability measure is able to detect contours with unusual lung outlines or errors in the processing. The method exploits the characteristics of dual-energy subtraction images to improve lung field segmenting performance.
引用
收藏
页码:45 / 56
页数:12
相关论文
共 50 条
  • [41] DUAL-ENERGY X-RAY ABSORPTIOMETRY - INTEREST IN ORTHOPEDICS
    MAUGARS, Y
    BERTHELOT, JM
    DELECRIN, J
    TRECANT, M
    PASSUTI, N
    DACULSI, G
    PROST, A
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 1995, 81 (04): : 326 - 332
  • [42] Technical standardization for dual-energy X-ray absorptiometry
    Leib, E
    JOURNAL OF CLINICAL DENSITOMETRY, 2004, 7 (01) : 27 - 36
  • [43] Dual-energy X-ray imaging: benefits and limits
    Rebuffel, V.
    Dinten, J-M
    INSIGHT, 2007, 49 (10) : 589 - 594
  • [44] SIMULATION STUDIES OF DUAL-ENERGY X-RAY ABSORPTIOMETRY
    SORENSON, JA
    DUKE, PR
    SMITH, SW
    MEDICAL PHYSICS, 1989, 16 (01) : 75 - 80
  • [45] Dual-energy X-ray absorptiometry in early life
    Lapillonne, A
    Braillon, PM
    Delmas, PD
    Salle, BL
    HORMONE RESEARCH, 1997, 48 : 43 - 49
  • [46] Multiple view dual-energy x-ray imaging
    Evans, P
    Robinson, M
    Hon, HW
    35TH ANNUAL 2001 INTERNATIONAL CARNAHAN CONFERENCE ON SECURITY TECHNOLOGY, PROCEEDINGS, 2001, : 103 - 107
  • [47] ENHANCED PRECISION WITH DUAL-ENERGY X-RAY ABSORPTIOMETRY
    MAZESS, R
    CHESNUT, CH
    MCCLUNG, M
    GENANT, H
    CALCIFIED TISSUE INTERNATIONAL, 1992, 51 (01) : 14 - 17
  • [48] Simultaneous dual-energy X-ray stereo imaging
    Mokso, Rajmund
    Oberta, Peter
    JOURNAL OF SYNCHROTRON RADIATION, 2015, 22 : 1078 - 1082
  • [49] Dual-energy X-ray absorptiometry and body composition
    Laskey, MA
    NUTRITION, 1996, 12 (01) : 45 - 51
  • [50] The use of dual-energy x-ray absorptiometry in animals
    Grier, SJ
    Turner, AS
    Alvis, MR
    INVESTIGATIVE RADIOLOGY, 1996, 31 (01) : 50 - 62