Dual-energy X-ray imaging: benefits and limits

被引:78
|
作者
Rebuffel, V. [1 ]
Dinten, J-M [1 ]
机构
[1] DTBS, CEA LETI Minatec, F-38000 Grenoble, France
关键词
dual-energy; X-ray imaging; radiography; material characterisation; dual-energy system optimisation;
D O I
10.1784/insi.2007.49.10.589
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Both in radiographic and tomographic mode, conventional X-ray imaging provider information about the examined object which is not sufficient to characterise it precisely. The dual-energy X-ray technique, which works by combining two radiographs acquired at two distinct energies, permits to obtain both density and atomic number, thus information about material composition. Available systems usually perform energetic separation at the source level, but separation at the detector level is also possible,for linear detectors, especially those devoted to translating objects control. Dual-energy equations can be easily written and solved for monochromatic energy spectra and perfect detectors, but become complex when considering realistic spectra, detector sensitivity, and system non-linearity. The decomposition onto a material basis, using experimental dual-material calibration, allows an approximated system to be solved, while eliminating the effects of disturbances such as beam hardening. More generally, we analyse the various problems to be solved before benefiting from the dual-energy approach, and propose available solutions. We evaluate the influence of noise on the accuracy of results, which strongly influences the capability to distinguish materials. We review the aspects to be optimised when considering a specific industrial problem. Numerical simulation is an efficient tool for optimal system design. Various industrial applications are considered.
引用
收藏
页码:589 / 594
页数:6
相关论文
共 50 条
  • [1] Resolution enhancement in dual-energy x-ray imaging
    Gravel, P
    Després, P
    Beaudoin, G
    de Guise, JA
    Medical Imaging 2005: Image Processing, Pt 1-3, 2005, 5747 : 614 - 624
  • [2] Simultaneous dual-energy X-ray stereo imaging
    Mokso, Rajmund
    Oberta, Peter
    JOURNAL OF SYNCHROTRON RADIATION, 2015, 22 : 1078 - 1082
  • [3] Multiple view dual-energy x-ray imaging
    Evans, P
    Robinson, M
    Hon, HW
    35TH ANNUAL 2001 INTERNATIONAL CARNAHAN CONFERENCE ON SECURITY TECHNOLOGY, PROCEEDINGS, 2001, : 103 - 107
  • [4] Dual-Energy X-Ray Fluoroscopy Imaging System
    Virshup, G.
    Fu, D.
    Richmond, M.
    Mostafavi, H.
    Ganguly, A.
    MEDICAL PHYSICS, 2014, 41 (06) : 103 - 103
  • [5] Multiscale deformable registration for dual-energy x-ray imaging
    Gang, G. J.
    Varon, C. A.
    Kashani, H.
    Richard, S.
    Paul, N. S.
    Van Metter, R.
    Yorkston, J.
    Siewerdsen, J. H.
    MEDICAL PHYSICS, 2009, 36 (02) : 351 - 363
  • [6] Contrast Enhanced Dual-Energy X-Ray Imaging System
    Sattarivand, M.
    Darvish-Molla, S.
    MEDICAL PHYSICS, 2019, 46 (06) : E105 - E105
  • [7] Capabilities of Dual-Energy X-Ray Imaging in Medicine and Security
    Ryzhikov, Volodymyr D.
    Grinyov, Borys V.
    Opolonin, Oleksandr D.
    Galkin, Serhiy M.
    Lysetska, Olena K.
    Voronkin, Yevheniy F.
    Kostioukevitch, Serhiy A.
    PENETRATING RADIATION SYSTEMS AND APPLICATIONS XIII, 2012, 8509
  • [8] Spectral and dual-energy X-ray imaging for medical applications
    Fredenberg, Erik
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 878 : 74 - 87
  • [9] Parameter identification method for dual-energy X-ray imaging
    Osipov, Sergei
    Libin, Eduard
    Chakhlov, Sergei
    Osipov, Oleg
    Shtein, Alexander
    NDT & E INTERNATIONAL, 2015, 76 : 38 - 42
  • [10] Dual-energy X-ray absorptiometry
    Braillon, Pierre