Resolution enhancement in dual-energy x-ray imaging

被引:1
|
作者
Gravel, P [1 ]
Després, P [1 ]
Beaudoin, G [1 ]
de Guise, JA [1 ]
机构
[1] Ecole Technol Super, Montreal, PQ, Canada
关键词
X-ray; image processing; image noise; image deconvolution; super resolution;
D O I
10.1117/12.594717
中图分类号
TB8 [摄影技术];
学科分类号
0804 ;
摘要
We have developed a method that uses a large amount of a priori information to generate super resolution radiographs. We measured and modeled analytically the point spread function of a low-dose gas microstrip x-ray detector at several beam energies. We measured the relationship between the local image intensity and the noise variance in the radiographs. The soft-tissue signal in the images was modeled using a minimum-curvature filtering technique. These results were then combined into an image deconvolution procedure using wavelet filtering to reduce restoration noise while keeping the enhanced small-scale features. The method was applied to a resolution grid image to measure its effects on the detector's modulation transfer function. The restored images of a radiological human-torso phantom revealed small-scale details on the bones that were not seen before, and this, with improved SNR and image contrast. Dual-energy imaging was integrated to the restoration process in order to generate separate high-resolution images of the bones, the soft tissues, and the mean atomic number. This information could be used to detect bone micro-fractures in athletes and to assess bone demineralization in seniors due to osteoporosis. Super resolution radiographs are easier to segment due to their enhanced contrasts and uniform backgrounds; the boundaries of the features of interest can be delimited with sub-pixel accuracy. This is highly relevant to the morphometric analysis of complex bone structures like individual vertebrae. The restoration method can be automated for a clinical environment use.
引用
收藏
页码:614 / 624
页数:11
相关论文
共 50 条
  • [1] Dual-energy X-ray imaging: benefits and limits
    Rebuffel, V.
    Dinten, J-M
    INSIGHT, 2007, 49 (10) : 589 - 594
  • [2] Simultaneous dual-energy X-ray stereo imaging
    Mokso, Rajmund
    Oberta, Peter
    JOURNAL OF SYNCHROTRON RADIATION, 2015, 22 : 1078 - 1082
  • [3] Multiple view dual-energy x-ray imaging
    Evans, P
    Robinson, M
    Hon, HW
    35TH ANNUAL 2001 INTERNATIONAL CARNAHAN CONFERENCE ON SECURITY TECHNOLOGY, PROCEEDINGS, 2001, : 103 - 107
  • [4] Dual-Energy X-Ray Fluoroscopy Imaging System
    Virshup, G.
    Fu, D.
    Richmond, M.
    Mostafavi, H.
    Ganguly, A.
    MEDICAL PHYSICS, 2014, 41 (06) : 103 - 103
  • [5] Multiscale deformable registration for dual-energy x-ray imaging
    Gang, G. J.
    Varon, C. A.
    Kashani, H.
    Richard, S.
    Paul, N. S.
    Van Metter, R.
    Yorkston, J.
    Siewerdsen, J. H.
    MEDICAL PHYSICS, 2009, 36 (02) : 351 - 363
  • [6] Contrast Enhanced Dual-Energy X-Ray Imaging System
    Sattarivand, M.
    Darvish-Molla, S.
    MEDICAL PHYSICS, 2019, 46 (06) : E105 - E105
  • [7] Capabilities of Dual-Energy X-Ray Imaging in Medicine and Security
    Ryzhikov, Volodymyr D.
    Grinyov, Borys V.
    Opolonin, Oleksandr D.
    Galkin, Serhiy M.
    Lysetska, Olena K.
    Voronkin, Yevheniy F.
    Kostioukevitch, Serhiy A.
    PENETRATING RADIATION SYSTEMS AND APPLICATIONS XIII, 2012, 8509
  • [8] Spectral and dual-energy X-ray imaging for medical applications
    Fredenberg, Erik
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 878 : 74 - 87
  • [9] Parameter identification method for dual-energy X-ray imaging
    Osipov, Sergei
    Libin, Eduard
    Chakhlov, Sergei
    Osipov, Oleg
    Shtein, Alexander
    NDT & E INTERNATIONAL, 2015, 76 : 38 - 42
  • [10] Dual-energy X-ray absorptiometry
    Braillon, Pierre
    Peretti, Noel
    NUTRITION CLINIQUE ET METABOLISME, 2011, 25 (02): : 91 - 96