Resolution enhancement in dual-energy x-ray imaging

被引:1
|
作者
Gravel, P [1 ]
Després, P [1 ]
Beaudoin, G [1 ]
de Guise, JA [1 ]
机构
[1] Ecole Technol Super, Montreal, PQ, Canada
关键词
X-ray; image processing; image noise; image deconvolution; super resolution;
D O I
10.1117/12.594717
中图分类号
TB8 [摄影技术];
学科分类号
0804 ;
摘要
We have developed a method that uses a large amount of a priori information to generate super resolution radiographs. We measured and modeled analytically the point spread function of a low-dose gas microstrip x-ray detector at several beam energies. We measured the relationship between the local image intensity and the noise variance in the radiographs. The soft-tissue signal in the images was modeled using a minimum-curvature filtering technique. These results were then combined into an image deconvolution procedure using wavelet filtering to reduce restoration noise while keeping the enhanced small-scale features. The method was applied to a resolution grid image to measure its effects on the detector's modulation transfer function. The restored images of a radiological human-torso phantom revealed small-scale details on the bones that were not seen before, and this, with improved SNR and image contrast. Dual-energy imaging was integrated to the restoration process in order to generate separate high-resolution images of the bones, the soft tissues, and the mean atomic number. This information could be used to detect bone micro-fractures in athletes and to assess bone demineralization in seniors due to osteoporosis. Super resolution radiographs are easier to segment due to their enhanced contrasts and uniform backgrounds; the boundaries of the features of interest can be delimited with sub-pixel accuracy. This is highly relevant to the morphometric analysis of complex bone structures like individual vertebrae. The restoration method can be automated for a clinical environment use.
引用
收藏
页码:614 / 624
页数:11
相关论文
共 50 条
  • [21] Dual-Energy X-ray Imaging by Simultaneous Integration and Campbelling Readout
    Roessl, Ewald
    Thran, Axel
    Martens, Gerhard
    Istel, Thomas
    Proksa, Roland
    Schlomka, Jens-Peter
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2112 - 2115
  • [22] Enhancement of Lung Tumor Visibility by Dual-Energy X-Ray Imaging in An Anthropomorphic Chest Phantom Study
    Menten, M. J.
    Fast, M. F.
    Nill, S.
    Oelfke, U.
    MEDICAL PHYSICS, 2014, 41 (06) : 510 - 510
  • [23] DUAL-ENERGY X-RAY ABSORPTIOMETRY OF THE FOREARM
    ROOS, JC
    TENKROODE, K
    LIPS, P
    TEULE, GJJ
    VANLINGEN, A
    JOURNAL OF NUCLEAR MEDICINE, 1993, 34 (05) : P110 - P111
  • [24] ACRONYM FOR DUAL-ENERGY X-RAY ABSORPTIOMETRY
    WILSON, CR
    COLLIER, BD
    CARRERA, GF
    JACOBSON, DR
    RADIOLOGY, 1990, 176 (03) : 875 - 875
  • [25] REPRODUCIBILITY OF DUAL-ENERGY X-RAY ABSORPTIOMETRY
    CHILIBECK, P
    CALDER, A
    SALE, DG
    WEBBER, C
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 1994, 45 (04): : 297 - 302
  • [26] LIMITATIONS OF DUAL-ENERGY X-RAY ABSORPTIOMETRY
    TOTHILL, P
    NORD, RH
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 1995, 61 (02): : 398 - 399
  • [27] Dual-energy x-ray absorptiometry in obesity
    Bazzocchi, Alberto
    Diano, Danila
    CANADIAN MEDICAL ASSOCIATION JOURNAL, 2014, 186 (01) : 48 - 48
  • [28] An Update on Dual-Energy X-Ray Absorptiometry
    Blake, Glen M.
    Fogelman, Ignac
    SEMINARS IN NUCLEAR MEDICINE, 2010, 40 (01) : 62 - 73
  • [29] DUAL-ENERGY X-RAY ABSORPTIOMETRY IN THE NEWBORN
    SALLE, BL
    LAPILLONNE, A
    BRAILLON, P
    ARCHIVES FRANCAISES DE PEDIATRIE, 1993, 50 (07): : 545 - 546
  • [30] Dual-energy x-ray absorptiometry in osteopetrosis
    Adler, IN
    Stine, KC
    Kurtzburg, J
    Kinder, DL
    Cox, KS
    Lensing, SY
    Seibert, JJ
    SOUTHERN MEDICAL JOURNAL, 2000, 93 (05) : 501 - 503