Dual-energy X-ray imaging: benefits and limits

被引:78
|
作者
Rebuffel, V. [1 ]
Dinten, J-M [1 ]
机构
[1] DTBS, CEA LETI Minatec, F-38000 Grenoble, France
关键词
dual-energy; X-ray imaging; radiography; material characterisation; dual-energy system optimisation;
D O I
10.1784/insi.2007.49.10.589
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Both in radiographic and tomographic mode, conventional X-ray imaging provider information about the examined object which is not sufficient to characterise it precisely. The dual-energy X-ray technique, which works by combining two radiographs acquired at two distinct energies, permits to obtain both density and atomic number, thus information about material composition. Available systems usually perform energetic separation at the source level, but separation at the detector level is also possible,for linear detectors, especially those devoted to translating objects control. Dual-energy equations can be easily written and solved for monochromatic energy spectra and perfect detectors, but become complex when considering realistic spectra, detector sensitivity, and system non-linearity. The decomposition onto a material basis, using experimental dual-material calibration, allows an approximated system to be solved, while eliminating the effects of disturbances such as beam hardening. More generally, we analyse the various problems to be solved before benefiting from the dual-energy approach, and propose available solutions. We evaluate the influence of noise on the accuracy of results, which strongly influences the capability to distinguish materials. We review the aspects to be optimised when considering a specific industrial problem. Numerical simulation is an efficient tool for optimal system design. Various industrial applications are considered.
引用
收藏
页码:589 / 594
页数:6
相关论文
共 50 条
  • [21] DUAL-ENERGY X-RAY ABSORPTIOMETRY OF THE FOREARM
    ROOS, JC
    TENKROODE, K
    LIPS, P
    TEULE, GJJ
    VANLINGEN, A
    JOURNAL OF NUCLEAR MEDICINE, 1993, 34 (05) : P110 - P111
  • [22] ACRONYM FOR DUAL-ENERGY X-RAY ABSORPTIOMETRY
    WILSON, CR
    COLLIER, BD
    CARRERA, GF
    JACOBSON, DR
    RADIOLOGY, 1990, 176 (03) : 875 - 875
  • [23] REPRODUCIBILITY OF DUAL-ENERGY X-RAY ABSORPTIOMETRY
    CHILIBECK, P
    CALDER, A
    SALE, DG
    WEBBER, C
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 1994, 45 (04): : 297 - 302
  • [24] LIMITATIONS OF DUAL-ENERGY X-RAY ABSORPTIOMETRY
    TOTHILL, P
    NORD, RH
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 1995, 61 (02): : 398 - 399
  • [25] Dual-energy x-ray absorptiometry in obesity
    Bazzocchi, Alberto
    Diano, Danila
    CANADIAN MEDICAL ASSOCIATION JOURNAL, 2014, 186 (01) : 48 - 48
  • [26] An Update on Dual-Energy X-Ray Absorptiometry
    Blake, Glen M.
    Fogelman, Ignac
    SEMINARS IN NUCLEAR MEDICINE, 2010, 40 (01) : 62 - 73
  • [27] DUAL-ENERGY X-RAY ABSORPTIOMETRY IN THE NEWBORN
    SALLE, BL
    LAPILLONNE, A
    BRAILLON, P
    ARCHIVES FRANCAISES DE PEDIATRIE, 1993, 50 (07): : 545 - 546
  • [28] Dual-energy x-ray absorptiometry in osteopetrosis
    Adler, IN
    Stine, KC
    Kurtzburg, J
    Kinder, DL
    Cox, KS
    Lensing, SY
    Seibert, JJ
    SOUTHERN MEDICAL JOURNAL, 2000, 93 (05) : 501 - 503
  • [29] Overlapped objects discrimination using dual-energy, high energy X-ray imaging
    Li, Qinghua
    Li, Jianmin
    Wang, Xuewu
    Zhang, Li
    Kang, Kejun
    Zhong, Huaqiang
    Qinghua Daxue Xuebao/Journal of Tsinghua University, 2008, 48 (08): : 1256 - 1259
  • [30] X-RAY-IMAGING SENSOR USING CDTE CRYSTALS FOR DUAL-ENERGY X-RAY ABSORPTIOMETRY
    OHTSUCHI, T
    TSUTSUI, H
    OHMORI, K
    BABA, S
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (05) : 1740 - 1745