Lung field segmenting in dual-energy subtraction chest x-ray images

被引:8
|
作者
Alvarez, RE [1 ]
机构
[1] Aprend Technol, Mountain View, CA 94043 USA
关键词
lung; segmenting; dual-energy subtraction; chest; x-ray;
D O I
10.1007/s10278-003-1701-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to develop and test a method to delineate lung field boundaries in dual-energy chest x-ray images. The segmenting method uses soft-tissue images and spatial frequency-dependent, background-subtracted images. Large-scale chest anatomy features are located and used to select the lung apices, the lateral lung boundaries, and the lung-mediastinum and lung-diaphragm boundaries. Extraneous parts of the contours are removed and they are joined to form complete lung boundaries. The reliability measure uses a statistical shape model to estimate the probability of occurrence of a contour. The method was experimentally tested with 30 human subject images. It has higher accuracy and specificity and a sensitivity parameter equal to the best previously reported method. The reliability measure is able to detect contours with unusual lung outlines or errors in the processing. The method exploits the characteristics of dual-energy subtraction images to improve lung field segmenting performance.
引用
收藏
页码:45 / 56
页数:12
相关论文
共 50 条
  • [31] Embossed x-ray computed tomography utilizing pixel-shifted dual-energy subtraction
    Ito, Kazuki
    Sato, Eiichi
    Oda, Yasuyuki
    Moriyama, Hodaka
    Hagiwara, Osahiko
    Enomoto, Toshiyuki
    Yoshida, Sohei
    Watanabe, Manabu
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2024, 95 (07):
  • [32] CHEST IMAGING WITH DUAL-ENERGY SUBTRACTION DIGITAL TOMOSYNTHESIS
    SONE, S
    KASUGA, T
    SAKAI, F
    HIRANO, H
    KUBO, K
    MORIMOTO, M
    TAKEMURA, K
    HOSOBA, M
    ACTA RADIOLOGICA, 1993, 34 (04) : 346 - 350
  • [33] THE APPLICATION OF X-RAY PHOSPHORS IN DUAL ENERGY SUBTRACTION
    HO, JT
    KRUGER, RA
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1988, 135 (08) : C389 - C389
  • [34] The effect of adiposity measured by dual-energy X-ray absorptiometry on lung function
    Sutherland, T. J. T.
    Goulding, A.
    Grant, A. M.
    Cowan, J. O.
    Williamson, A.
    Williams, S. M.
    Skinner, M. A.
    Taylor, D. R.
    EUROPEAN RESPIRATORY JOURNAL, 2008, 32 (01) : 85 - 91
  • [35] DUAL-ENERGY X-RAY ABSORPTIOMETRY OF THE CALCANEUS - COMPARISON WITH VERTEBRAL DUAL-ENERGY X-RAY ABSORPTIOMETRY AND QUANTITATIVE COMPUTED-TOMOGRAPHY
    LAVALJEANTET, AM
    BERGOT, C
    WILLIAMS, M
    DAVIDSON, K
    LAVALJEANTET, M
    CALCIFIED TISSUE INTERNATIONAL, 1995, 56 (01) : 14 - 18
  • [36] Application of TransUNet for Segmenting Lung Mass from Chest X-ray Image
    Chang, Chuan-Yu
    Lin, Tin-Kwang
    Lin, Chih-Wen
    Cheng, Hsin-Tien
    2022 IEEE INTERNATIONAL CONFERENCE ON CONSUMER ELECTRONICS - TAIWAN, IEEE ICCE-TW 2022, 2022, : 175 - 176
  • [37] The Use of Dual-Energy X-ray Absorptiometry Images to evaluate the risk of bone Fracture
    Bettamer, Awad
    Almhdie-Imjabber, Ahmad
    Hambli, Ridha
    Allaoui, Samir
    Mahmud, Mussa
    Jennane, Rachid
    5TH INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, THEORY, TOOLS AND APPLICATIONS 2015, 2015, : 319 - 322
  • [38] Resolution enhancement in dual-energy x-ray imaging
    Gravel, P
    Després, P
    Beaudoin, G
    de Guise, JA
    Medical Imaging 2005: Image Processing, Pt 1-3, 2005, 5747 : 614 - 624
  • [39] Dual-energy X-ray absorptiometry scan: Guidelines
    Haymann, Jean-Philippe
    PROGRES EN UROLOGIE, 2010, 20 (04): : F119 - F122
  • [40] DUAL-ENERGY X-RAY ABSORPTIOMETRY IN NEUROMUSCULAR DISEASES
    KANDA, F
    FUJII, Y
    TAKAHASHI, K
    FUJITA, T
    MUSCLE & NERVE, 1994, 17 (04) : 431 - 435