First results with a novel X-ray source for dual energy angiography

被引:0
|
作者
Baldazzi, G [1 ]
Bollini, D [1 ]
Celesti, E [1 ]
Gambaccini, M [1 ]
Gombia, M [1 ]
Labanti, C [1 ]
Taibi, A [1 ]
Tuffanelli, A [1 ]
机构
[1] Univ Bologna, Dept Phys, I-40127 Bologna, Italy
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In angiographic practice an iodate contrast medium is injected in patient vessels with a catheter. The iodine is used because its linear absorption coefficient shows a K-edge at 33.169 keV. In Digital Subtraction Angiography (DSA), some images are acquired before and during the injection of the contrast medium. The vessels' morphology is obtained by subtracting the live images from the first (mask) image. A new approach is presented where two quasi-monochromatic beams, having mean energies lower and higher than the iodine K-edge, are produced simultaneously - starting from an X-ray tube - by means of a pyrolytic graphite crystal monochromator. These two thin parallel beams impinge on the phantom simulating patient vessels and are detected with solid-state array detectors. The image results as the difference between the remaining intensities of the two beams. Performance - in terms of spatial resolution, contrast and reduction of iodine concentration in an invasive perfusion medium - will be presented and compared with the full spectra subtraction method in use.
引用
收藏
页码:1615 / 1619
页数:5
相关论文
共 50 条
  • [1] Novel x-ray source for dual-energy subtraction angiography
    Tuffanelli, A
    Taibi, A
    Baldazzi, G
    Bollini, D
    Gombia, M
    Ramello, L
    Gambaccini, M
    [J]. MEDICAL IMAGING 2002: PHYSICS OF MEDICAL IMAGING, 2002, 4682 : 311 - 319
  • [2] A K-ALPHA DUAL ENERGY X-RAY SOURCE FOR CORONARY ANGIOGRAPHY
    MANNING, HL
    SHEFER, RE
    KLINKOWSTEIN, RE
    MISTRETTA, CA
    [J]. MEDICAL PHYSICS, 1991, 18 (05) : 880 - 893
  • [3] Laser-driven x-ray source for angiography: Preliminary results
    Krol, A
    Ikhlef, A
    Kieffer, JC
    Bassano, DA
    Chamberlain, CC
    Prasad, SC
    [J]. RADIOLOGY, 1996, 201 : 1084 - 1084
  • [4] Dual-energy X-ray CT by Compton scattering hard X-ray source
    Kaneyasu, T
    Uesaka, N
    Dobashi, K
    Torikoshi, M
    [J]. 2005 IEEE PARTICLE ACCELERATOR CONFERENCE (PAC), VOLS 1-4, 2005, : 1680 - 1682
  • [5] FIRST RESULTS FROM A NOVEL MICROFOCUS X-RAY GENERATOR FOR X-RAY CRYSTALLOGRAPHY
    Ciszak, Ewa
    Gubarev, Mikhail
    Joy, Marshall
    Gibson, Walter
    [J]. ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 1999, 55 : 82 - 82
  • [6] First dual energy X-ray absorptiometry scanner in China
    [J]. 2001, Atomic Energy Press (21):
  • [7] Dual energy X-ray absorptiometry
    Winzenberg, Tania
    Jones, Graeme
    [J]. AUSTRALIAN FAMILY PHYSICIAN, 2011, 40 (1-2) : 43 - 44
  • [8] Parametric X-ray radiation as a novel source for X-ray imaging
    Takahashi, Yumiko
    Hayakawa, Yasushi
    Kuwada, Takao
    Tanaka, Toshinari
    Sakae, Toshiro
    Nakao, Keisuke
    Nogami, Kyoko
    Imagaki, Manabu
    Hayakawa, Ken
    Sato, Isamu
    [J]. X-RAY SPECTROMETRY, 2012, 41 (04) : 210 - 215
  • [9] NONINVASIVE DIGITAL ENERGY SUBTRACTION ANGIOGRAPHY WITH A CHANNELING-RADIATION X-RAY SOURCE
    GARY, CK
    PIESTRUP, MA
    BOYERS, DG
    PINCUS, CI
    PANTELL, RH
    ROTHBART, GB
    [J]. MEDICAL PHYSICS, 1993, 20 (05) : 1527 - 1535
  • [10] Dual-Energy X-Ray Absorptiometry (DEXA): A Novel Approach for the Evaluation of Abdominal Liposuction Results
    Hangyan Shi
    Qifeng Ying
    Sheng Yan
    Da Chen
    Jincai Guo
    Yi Sun
    Yong Chen
    Sufan Wu
    [J]. Aesthetic Plastic Surgery, 2009, 33 : 235 - 239