The Reliability and Validity of Wearable Inertial Sensors Coupled with the Microsoft Kinect to Measure Shoulder Range-of-Motion

被引:18
|
作者
Beshara, Peter [1 ,2 ,3 ]
Chen, Judy F. [1 ,2 ]
Read, Andrew C. [1 ]
Lagadec, Pierre [4 ]
Wang, Tian [2 ,3 ]
Walsh, William Robert [2 ,3 ]
机构
[1] Prince Wales Hosp, Dept Physiotherapy, Sydney, NSW 2031, Australia
[2] Univ New South Wales, Fac Med, Prince Wales Clin Sch, Sydney, NSW 2031, Australia
[3] Prince Wales Hosp, Surg & Orthopaed Res Labs, Sydney, NSW 2301, Australia
[4] Vald Performance, Brisbane, Qld 4006, Australia
关键词
shoulder; range of motion; sensor; Kinect; goniometry; measurement; INTEROBSERVER REPRODUCIBILITY; DIGITAL INCLINOMETER; CONCURRENT VALIDITY; TEST-RETEST; GONIOMETER; MOVEMENT; KINEMATICS; SYSTEM;
D O I
10.3390/s20247238
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: Objective assessment of shoulder joint active range of motion (AROM) is critical to monitor patient progress after conservative or surgical intervention. Advancements in miniature devices have led researchers to validate inertial sensors to capture human movement. This study investigated the construct validity as well as intra- and inter-rater reliability of active shoulder mobility measurements using a coupled system of inertial sensors and the Microsoft Kinect (HumanTrak). Methods: 50 healthy participants with no history of shoulder pathology were tested bilaterally for fixed and free ROM: (1) shoulder flexion, and (2) abduction using HumanTrak and goniometry. The repeat testing of the standardised protocol was completed after seven days by two physiotherapists. Results: All HumanTrak shoulder movements demonstrated adequate reliability (intra-class correlation (ICC) >= 0.70). HumanTrak demonstrated higher intra-rater reliability (ICCs: 0.93 and 0.85) than goniometry (ICCs: 0.75 and 0.53) for measuring free shoulder flexion and abduction AROM, respectively. Similarly, HumanTrak demonstrated higher intra-rater reliability (ICCs: 0.81 and 0.94) than goniometry (ICCs: 0.70 and 0.93) for fixed flexion and abduction AROM, respectively. Construct validity between HumanTrak and goniometry was adequate except for free abduction. The differences between raters were predominately acceptable and below +/- 10 degrees. Conclusions: These results indicated that the HumanTrak system is an objective, valid and reliable way to assess and track shoulder ROM.
引用
收藏
页码:1 / 16
页数:16
相关论文
共 50 条
  • [1] Test-Retest and Intra-rater Reliability of Using Inertial Sensors and Its Integration with Microsoft Kinect™ to Measure Shoulder Range-of-Motion
    Beshara, Peter
    Chen, Judy
    Lagadec, Pierre
    Walsh, W. R.
    [J]. INTERNET OF THINGS TECHNOLOGIES FOR HEALTHCARE, HEALTHYIOT 2016, 2016, 187 : 177 - 184
  • [2] The Reliability of the Microsoft Kinect and Ambulatory Sensor-Based Motion Tracking Devices to Measure Shoulder Range-of-Motion: A Systematic Review and Meta-Analysis
    Beshara, Peter
    Anderson, David B.
    Pelletier, Matthew
    Walsh, William R.
    [J]. SENSORS, 2021, 21 (24)
  • [3] RELIABILITY AND VALIDITY OF THE SINGLE-CAMERA MARKERLESS MOTION CAPTURE SYSTEM FOR MEASURING SHOULDER RANGE-OF-MOTION
    Lee, Seunghoon
    Lee, Suji
    Lee, Hungu
    Kim, Yohwan
    [J]. OSTEOARTHRITIS AND CARTILAGE, 2024, 32 : S233 - S233
  • [4] Validity and reliability of inertial sensors for elbow and wrist range of motion assessment
    Costa, Vanina
    Ramirez, Oscar
    Otero, Abraham
    Munoz-Garcia, Daniel
    Uribarri, Sandra
    Raya, Rafael
    [J]. PEERJ, 2020, 8
  • [5] Wearable Inertial Sensors for Range of Motion Assessment
    Rajkumar, Ashwin
    Vulpi, Fabio
    Bethi, Satish Reddy
    Wazir, Hassam Khan
    Raghavan, Preeti
    Kapila, Vikram
    [J]. IEEE SENSORS JOURNAL, 2020, 20 (07) : 3777 - 3787
  • [6] The concurrent validity and intrarater reliability of the Microsoft Kinect to measure thoracic kyphosis
    Quek, June
    Brauer, Sandra G.
    Treleaven, Julia
    Clark, Ross A.
    [J]. INTERNATIONAL JOURNAL OF REHABILITATION RESEARCH, 2017, 40 (03) : 279 - 284
  • [8] Validity and intra-rater reliability of an Android phone application to measure cervical range-of-motion
    Quek, June
    Brauer, Sandra G.
    Treleaven, Julia
    Pua, Yong-Hao
    Mentiplay, Benjamin
    Clark, Ross Allan
    [J]. JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2014, 11
  • [9] Validity and intra-rater reliability of an Android phone application to measure cervical range-of-motion
    June Quek
    Sandra G Brauer
    Julia Treleaven
    Yong-Hao Pua
    Benjamin Mentiplay
    Ross Allan Clark
    [J]. Journal of NeuroEngineering and Rehabilitation, 11
  • [10] VALIDITY AND RELIABILITY OF THE SINGLE CAMERA MARKERLESS MOTION CAPTURE SYSTEM USING RGB-D SENSOR TO MEASURE SHOULDER RANGE-OF-MOTION: A SYSTEMATIC REVIEW
    Kim, Yohwan
    Lee, Suji
    Lee, Unhyung
    Lee, Hungu
    Lee, Seunghoon
    [J]. OSTEOARTHRITIS AND CARTILAGE, 2024, 32 : S236 - S236