The Reliability and Validity of Wearable Inertial Sensors Coupled with the Microsoft Kinect to Measure Shoulder Range-of-Motion

被引:18
|
作者
Beshara, Peter [1 ,2 ,3 ]
Chen, Judy F. [1 ,2 ]
Read, Andrew C. [1 ]
Lagadec, Pierre [4 ]
Wang, Tian [2 ,3 ]
Walsh, William Robert [2 ,3 ]
机构
[1] Prince Wales Hosp, Dept Physiotherapy, Sydney, NSW 2031, Australia
[2] Univ New South Wales, Fac Med, Prince Wales Clin Sch, Sydney, NSW 2031, Australia
[3] Prince Wales Hosp, Surg & Orthopaed Res Labs, Sydney, NSW 2301, Australia
[4] Vald Performance, Brisbane, Qld 4006, Australia
关键词
shoulder; range of motion; sensor; Kinect; goniometry; measurement; INTEROBSERVER REPRODUCIBILITY; DIGITAL INCLINOMETER; CONCURRENT VALIDITY; TEST-RETEST; GONIOMETER; MOVEMENT; KINEMATICS; SYSTEM;
D O I
10.3390/s20247238
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: Objective assessment of shoulder joint active range of motion (AROM) is critical to monitor patient progress after conservative or surgical intervention. Advancements in miniature devices have led researchers to validate inertial sensors to capture human movement. This study investigated the construct validity as well as intra- and inter-rater reliability of active shoulder mobility measurements using a coupled system of inertial sensors and the Microsoft Kinect (HumanTrak). Methods: 50 healthy participants with no history of shoulder pathology were tested bilaterally for fixed and free ROM: (1) shoulder flexion, and (2) abduction using HumanTrak and goniometry. The repeat testing of the standardised protocol was completed after seven days by two physiotherapists. Results: All HumanTrak shoulder movements demonstrated adequate reliability (intra-class correlation (ICC) >= 0.70). HumanTrak demonstrated higher intra-rater reliability (ICCs: 0.93 and 0.85) than goniometry (ICCs: 0.75 and 0.53) for measuring free shoulder flexion and abduction AROM, respectively. Similarly, HumanTrak demonstrated higher intra-rater reliability (ICCs: 0.81 and 0.94) than goniometry (ICCs: 0.70 and 0.93) for fixed flexion and abduction AROM, respectively. Construct validity between HumanTrak and goniometry was adequate except for free abduction. The differences between raters were predominately acceptable and below +/- 10 degrees. Conclusions: These results indicated that the HumanTrak system is an objective, valid and reliable way to assess and track shoulder ROM.
引用
收藏
页码:1 / 16
页数:16
相关论文
共 50 条
  • [11] A Brief Review on the Validity and Reliability of Microsoft Kinect Sensors for Functional Assessment Applications
    Rodrigo Diaz-Monterrosas, Pablo
    Posada-Gomez, Ruben
    Martinez-Sibaja, Albino
    Alfonso Aguilar-Lasserre, Alberto
    Juarez-Martinez, Ulises
    Carlos Trujillo-Caballero, Juan
    [J]. ADVANCES IN ELECTRICAL AND COMPUTER ENGINEERING, 2018, 18 (01) : 131 - 136
  • [12] Reliability and agreement of Azure Kinect and Kinect v2 depth sensors in the shoulder joint range of motion estimation
    Ozsoy, Umut
    Yildirim, Yilmaz
    Karasin, Sezen
    Sekerci, Rahime
    Suzen, Lutfiye Bikem
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2022, 31 (10) : 2049 - 2056
  • [13] The concurrent validity and reliability of virtual reality to measure shoulder flexion and scaption range of motion
    Dejaco, Beate
    de Jong, Lex D.
    van Goor, Harry
    Staal, J. Bart
    Stolwijk, Niki
    Lewis, Jeremy
    [J]. PHYSIOTHERAPY, 2023, 120 : 95 - 102
  • [14] Shoulder Range of Motion Measurement Using Inertial Measurement Unit-Concurrent Validity and Reliability
    Kaszynski, Jakub
    Baka, Cezary
    Bialecka, Martyna
    Lubiatowski, Przemyslaw
    [J]. SENSORS, 2023, 23 (17)
  • [15] INTER, INTRA-EXAMINER RELIABILITY AND VALIDITY OF INERTIAL SENSORS TO MEASURE THE ACTIVE CERVICAL RANGE OF MOTION IN PATIENTS WITH PRIMARY HEADACHE
    Elizagaray-Garcia, Ignacio
    Gil-Martinez, Alfonso
    Navarro-Fernandez, Gonzalo
    Navarro-Moreno, Ana R.
    Sanchez-de-Toro-Hernandez, Jacqueline
    Diaz-de-Teran, Javier
    Lerma-Lara, Sergio
    [J]. EXCLI JOURNAL, 2021, 20 : 879 - 893
  • [16] The reliability and validity of a novel wearable inertial sensor to measure the cervical proprioception
    Wang, Jialin
    Wang, Ruirui
    Zhao, Peng
    Han, Tianran
    Cui, Xinwen
    He, Yuwei
    Li, Meng
    [J]. MEDICAL ENGINEERING & PHYSICS, 2024, 125
  • [17] Validity and Reliability of Wearable Motion Sensors for Clinical Assessment of Shoulder Function in Brachial Plexus Birth Injury
    Grip, Helena
    Kallstromer, Anna
    Ohberg, Fredrik
    [J]. SENSORS, 2022, 22 (23)
  • [18] Assessment of Shoulder Range of Motion Using a Wearable Inertial Sensor Network
    Lin, Yu-Ching
    Tsai, Yi-Ju
    Hsu, Yu-Liang
    Yen, Ming-Hsin
    Wang, Jeen-Shing
    [J]. IEEE SENSORS JOURNAL, 2021, 21 (13) : 15330 - 15341
  • [19] Comparing Real-time Human Motion Capture System using Inertial Sensors with Microsoft Kinect
    Xiang, Chengkai
    Hsu, Hui-Huang
    Hwang, Wu-Yuin
    Ma, Jianhua
    [J]. 2014 7TH INTERNATIONAL CONFERENCE ON UBI-MEDIA COMPUTING AND WORKSHOPS (UMEDIA), 2014, : 53 - 58
  • [20] Measurement of lumbar spine range of movement and coupled motion using inertial sensors - A protocol validity study
    Ha, Tshui-Hung
    Saber-Sheikh, Kambiz
    Moore, Ann P.
    Jones, Mark P.
    [J]. MANUAL THERAPY, 2013, 18 (01) : 87 - 91