Test-Retest and Intra-rater Reliability of Using Inertial Sensors and Its Integration with Microsoft Kinect™ to Measure Shoulder Range-of-Motion

被引:4
|
作者
Beshara, Peter [1 ]
Chen, Judy [1 ]
Lagadec, Pierre [1 ]
Walsh, W. R. [1 ]
机构
[1] UNSW Australia, Physiotherapy Dept, Prince Wales Clin Sch, Prince Wales Hosp, High St, Sydney, NSW 2031, Australia
关键词
Inertial sensors; Kinematics; Joint angle tracking; Wearable devices; Shoulder; ARM; TRIAL; PAIN;
D O I
10.1007/978-3-319-51234-1_31
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
This study determined the intra-rater and test-retest reliability of a novel motion-tracking system that integrates inertial sensors with Microsoft Kinect to measure peak shoulder range-of-motion (ROM) angles. Nine healthy individuals (6 female and 3 male, age: 36.6 +/- 13.3) with no shoulder pathology participated following ethical approval. Participants performed active shoulder forward flexion and abduction to the end of available range. Repeat testing of the protocol was completed after 7 days by the same rater. Results demonstrated excellent intra-rater reliability (ICC = 0.84, 0.93) for shoulder flexion and modest-excellent intra-rater reliability (ICC = 0.82, 0.52) for shoulder abduction. A high level of correlation was observed between week 1 and 2 for flexion and abduction (R = 0.85 0.93), expect for left abduction (R = 0.60). In conclusion, an inertial system combined with the Kinect is a reliable tool to measure shoulder ROM and has the potential for future research and clinical application.
引用
收藏
页码:177 / 184
页数:8
相关论文
共 32 条
  • [1] The Reliability and Validity of Wearable Inertial Sensors Coupled with the Microsoft Kinect to Measure Shoulder Range-of-Motion
    Beshara, Peter
    Chen, Judy F.
    Read, Andrew C.
    Lagadec, Pierre
    Wang, Tian
    Walsh, William Robert
    [J]. SENSORS, 2020, 20 (24) : 1 - 16
  • [2] Validity and intra-rater reliability of an Android phone application to measure cervical range-of-motion
    Quek, June
    Brauer, Sandra G.
    Treleaven, Julia
    Pua, Yong-Hao
    Mentiplay, Benjamin
    Clark, Ross Allan
    [J]. JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2014, 11
  • [3] Validity and intra-rater reliability of an Android phone application to measure cervical range-of-motion
    June Quek
    Sandra G Brauer
    Julia Treleaven
    Yong-Hao Pua
    Benjamin Mentiplay
    Ross Allan Clark
    [J]. Journal of NeuroEngineering and Rehabilitation, 11
  • [4] Test-retest intra-rater reliability of grip force in patients with stroke
    Hammer, A
    Lindmark, B
    [J]. JOURNAL OF REHABILITATION MEDICINE, 2003, 35 (04) : 189 - 194
  • [5] Inter-rater, intra-rater, and test-retest reliability of photonumeric grading scales using photographs
    Korgavkar, K.
    Weinstock, M. A.
    Lee, K.
    [J]. JOURNAL OF INVESTIGATIVE DERMATOLOGY, 2017, 137 (05) : S29 - S29
  • [6] INTRA-RATER TEST-RETEST RELIABILITY AND RESPONSE STABILITY OF THE FUSIONETICS (TM) MOVEMENT EFFICIENCY TEST
    Cornell, David J.
    Ebersole, Kyle T.
    [J]. INTERNATIONAL JOURNAL OF SPORTS PHYSICAL THERAPY, 2018, 13 (04): : 618 - 632
  • [7] Test-retest, inter- and intra-rater reliability of the flexicurve for evaluation of the spine in children
    Sedrez, Juliana A.
    Candotti, Claudia T.
    Rosa, Maria I. Z.
    Medeiros, Fernanda S.
    Marques, Mariana T.
    Loss, Jefferson F.
    [J]. BRAZILIAN JOURNAL OF PHYSICAL THERAPY, 2016, 20 (02) : 142 - 147
  • [8] Inter-rater and intra-rater reliability of Kinovea software for measurement of shoulder range of motion
    Reham M. Abd Elrahim
    Eman A. Embaby
    Mohamed F. Ali
    Ragia M. Kamel
    [J]. Bulletin of Faculty of Physical Therapy, 2016, 21 (2) : 80 - 87
  • [9] Test-retest intra-rater reliability of vaginal measurement of pelvic floor muscle strength using Myomed 932
    Sigurdardottir, Thorgerdur
    Steingrimsdottir, Thora
    Arnason, Arni
    Bo, Kari
    [J]. ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2009, 88 (08) : 939 - 943
  • [10] Intra-rater and inter-rater reliability of cervical active range of movement in young asymptomatic adults using inertial sensors
    Anoro-Hervera, Alejandro
    Lafuente-Perez, Adrian
    Navarro-Fernandez, Gonzalo
    Munoz-Garcia, Daniel
    Lerma-Lara, Sergio
    Beltran-Alacreu, Hector
    [J]. EXPERT REVIEW OF MEDICAL DEVICES, 2019, 16 (12) : 1071 - 1077