On the effective point of measurement in megavoltage photon beams

被引:72
|
作者
Kawrakow, Iwan [1 ]
机构
[1] NRC, Ionizing Radiat Stand, Ottawa, ON K1A 0R6, Canada
关键词
D O I
10.1118/1.2201147
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This paper presents a numerical investigation of the effective point of measurement of thimble ionization chambers in megavoltage photon beams using Monte Carlo simulations with the EGSNRC system. It is shown that the effective point of measurement for relative photon beam dosimetry depends on every detail of the chamber design, including the cavity length, the mass density of the wall material, and the size of the central electrode, in addition to the cavity radius. Moreover. the effective point of measurement also depends on the beam quality and the field size. The paper therefore argues that the upstream shift of 0.6 times the cavity radius, recommended in current dosimetry protocols, is inadequate for accurate relative photon beam dosimetry, particularly in the build-up region. On the other hand, once the effective point of measurement is selected appropriately, measured depth-ionization curves can be equated to measured depth-dose curves for all depths within +/-0.5%.
引用
收藏
页码:1829 / 1839
页数:11
相关论文
共 50 条
  • [31] Quality assurance of measured depth dose for megavoltage photon beams
    Thompson, AV
    Zhu, TC
    Bjärngard, BE
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 3108 - 3111
  • [32] The response of a radiophotoluminescent glass dosimeter in megavoltage photon and electron beams
    Araki, Fujio
    Ohno, Takeshi
    MEDICAL PHYSICS, 2014, 41 (12)
  • [33] Dependence of surface dose on atomic number in megavoltage photon beams
    Khan, Ahtesham Ullah
    Das, Indra J.
    MEDICAL PHYSICS, 2024, 51 (08) : 5746 - 5753
  • [34] Modeling the headscatter off-axis in megavoltage photon beams
    Finlay, J
    Li, J
    Zhu, T
    MEDICAL PHYSICS, 2005, 32 (06) : 1997 - 1997
  • [35] THE APPLICATION OF THE APPROXIMATION METHOD OF EQUIVALENT SQUARE FOR MEGAVOLTAGE PHOTON BEAMS
    OSMAN, GE
    TSUNG, PN
    JOURNAL OF MEDICINE, 1980, 11 (2-3) : 117 - 125
  • [36] Characterization of Head Scatter Off Axis in Megavoltage Photon Beams
    Novak, J.
    Zhu, T.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [37] Empirical modeling of the percent depth dose for megavoltage photon beams
    Li, Xiao-Jun
    Ye, Yan-Cheng
    Zhang, Yan-Shan
    Wu, Jia-Ming
    PLOS ONE, 2022, 17 (01):
  • [38] On few-view tomographic reconstruction with megavoltage photon beams
    Loose, S
    Leszczynski, KW
    MEDICAL PHYSICS, 2001, 28 (08) : 1679 - 1688
  • [39] Intermediate Megavoltage Photon Beams for Improved Lung Cancer Treatments
    Zhang, Ying
    Feng, Yuanming
    Ahmad, Munir
    Ming, Xin
    Zhou, Li
    Deng, Jun
    PLOS ONE, 2015, 10 (12):
  • [40] Spectral reconstruction of clinical megavoltage photon beams and the implications of spectral determination on the dosimetry of such beams
    Nisbet, A
    Weatherburn, H
    Fenwick, JD
    McVey, G
    PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (06): : 1507 - 1521