On the effective point of measurement in megavoltage photon beams

被引:72
|
作者
Kawrakow, Iwan [1 ]
机构
[1] NRC, Ionizing Radiat Stand, Ottawa, ON K1A 0R6, Canada
关键词
D O I
10.1118/1.2201147
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This paper presents a numerical investigation of the effective point of measurement of thimble ionization chambers in megavoltage photon beams using Monte Carlo simulations with the EGSNRC system. It is shown that the effective point of measurement for relative photon beam dosimetry depends on every detail of the chamber design, including the cavity length, the mass density of the wall material, and the size of the central electrode, in addition to the cavity radius. Moreover. the effective point of measurement also depends on the beam quality and the field size. The paper therefore argues that the upstream shift of 0.6 times the cavity radius, recommended in current dosimetry protocols, is inadequate for accurate relative photon beam dosimetry, particularly in the build-up region. On the other hand, once the effective point of measurement is selected appropriately, measured depth-ionization curves can be equated to measured depth-dose curves for all depths within +/-0.5%.
引用
收藏
页码:1829 / 1839
页数:11
相关论文
共 50 条
  • [41] Investigating the Impact of Grid Collimators on Reference Dosimetry of Megavoltage Photon Beams
    Khan, A. U.
    Das, I. J.
    MEDICAL PHYSICS, 2024, 51 (09) : 6650 - 6650
  • [42] Validation of Monte Carlo calculated surface doses for megavoltage photon beams
    Abdel-Rahman, W
    Seuntjens, JP
    Verhaegen, F
    Deblois, F
    Podgorsak, EB
    MEDICAL PHYSICS, 2005, 32 (01) : 286 - 298
  • [43] Another look at the in-air output factors for megavoltage photon beams
    Palta, J
    Liu, C
    Dempsey, J
    Ding, G
    MEDICAL PHYSICS, 2004, 31 (06) : 1812 - 1812
  • [44] Dosimetric monitoring methods for megavoltage photon and electron beams in clinical radiotherapy
    Ravichandran, R.
    JOURNAL OF MEDICAL PHYSICS, 2011, 36 (03) : 184 - 185
  • [45] A LIQUID IONIZATION DETECTOR FOR DIGITAL RADIOGRAPHY OF THERAPEUTIC MEGAVOLTAGE PHOTON BEAMS
    MEERTENS, H
    VANHERK, M
    WEEDA, J
    PHYSICS IN MEDICINE AND BIOLOGY, 1985, 30 (04): : 313 - 321
  • [46] The Effect of Treatment Couch Attenuation On Radiation Dose for Megavoltage Photon Beams
    Li, H.
    Lee, A.
    Zhu, X.
    Kudchadker, R.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [47] Modeling scatter-to-primary dose ratio for megavoltage photon beams
    Wang, Ken Kang-Hsin
    Zhu, Timothy C.
    MEDICAL PHYSICS, 2010, 37 (10) : 5270 - 5278
  • [48] Evaluation of precalibrated implantable MOSFET radiation dosimeters for megavoltage photon beams
    Briere, TM
    Beddar, AS
    Gillin, MT
    MEDICAL PHYSICS, 2005, 32 (11) : 3346 - 3349
  • [49] Peripheral Dose Assessment Using NanoDot OSLD with Megavoltage Photon Beams
    Ponmalar, R.
    Manickam, R.
    Godson, H.
    Saminathan, S.
    Kadirampatti, G.
    Raman, A.
    MEDICAL PHYSICS, 2018, 45 (06) : E287 - E287
  • [50] Dose rate correction factors for diamond detectors for megavoltage photon beams
    Heydarian, M
    Zahmatkesh, M
    Hoban, PW
    Beddoe, AH
    PHYSICA MEDICA, 1997, 13 (02) : 55 - 60