Dependence of surface dose on atomic number in megavoltage photon beams

被引:0
|
作者
Khan, Ahtesham Ullah [1 ]
Das, Indra J. [1 ]
机构
[1] Northwestern Univ, Feinberg Sch Med, Northwestern Mem Hosp, Dept Radiat Oncol, 251 E Huron St,Galter Pavil,LC 100, Chicago, IL 60611 USA
基金
美国国家科学基金会;
关键词
atomic number dependence; megavoltage photon beams; Monte Carlo; surface dose; TRANSITION-ZONE DOSIMETRY; ENERGY; GEANT4; RAYS;
D O I
10.1002/mp.16979
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundSurface dose in megavoltage photon radiotherapy has a significant clinical impact on the skin-sparing effect. In previously published works, it was established that the presence of medium atomic number (Z) absorbers, such as tin, decreases the surface dose. It was concluded that high-Z absorbers, such as lead, increase the surface dose, relative to medium-Z absorbers, due to the increased contributions from photoelectrons and electron-positron pairs.PurposeThe purpose of this investigation is to revisit these conclusions in the context of photon beams from modern linacs.MethodsA metric estimating the relative intensity of charged particles emitted in the forward direction, If${I}_f$, was proposed using cross-sections for the photon interactions. The If${I}_f$ values were calculated for various absorbers using energy spectra of 6 and 10 MV photon beams from a Varian TrueBeam linac. Monte Carlo (MC) simulations were performed using TOPAS MC code to calculate the surface dose for various absorbers. Surface dose measurements were performed with 6 and 10 MV photon beams with tin and lead absorbers.ResultsThe If${I}_f$ values were found to decrease as a function of Z for both 6 and 10 MV photon beams indicating that the surface dose from electrons emitted in the forward direction consistently decreases with increasing Z. With the increasing Z of the absorbers, both experimental and MC-calculated surface dose decreased without exhibiting a minimum at medium-Z absorbers. The surface dose for lead and tin was determined to be within 1% of each other for both 6 and 10 MV photon beams using MC simulations and experimental measurements. Therefore, no statistically significant difference in surface dose was found between the tin and lead absorbers disproving the presence of any minima in the surface dose versus the Z curve as has been reported in the literature.ConclusionsSurface dose for modern photon beams can be reduced using both medium and high Z absorbers since a consistent decrease in surface dose was found with increasing absorber Z.
引用
收藏
页码:5746 / 5753
页数:8
相关论文
共 50 条
  • [1] BACKSCATTER DOSE PERTURBATION AT HIGH ATOMIC-NUMBER INTERFACES IN MEGAVOLTAGE PHOTON BEAMS
    DAS, IJ
    KAHN, FM
    MEDICAL PHYSICS, 1989, 16 (03) : 367 - 375
  • [2] DOSE MEASUREMENT AT HIGH ATOMIC-NUMBER INTERFACES IN MEGAVOLTAGE PHOTON BEAMS USING TLDS
    PRADHAN, AS
    GOPALAKRISHNAN, AK
    IYER, PS
    MEDICAL PHYSICS, 1992, 19 (02) : 355 - 356
  • [3] SURFACE DOSE FOR MEGAVOLTAGE PHOTON BEAMS OUTSIDE THE TREATMENT FIELD
    STARKSCHALL, G
    STGEORGE, FJ
    ZELLMER, DL
    MEDICAL PHYSICS, 1983, 10 (06) : 906 - 910
  • [4] SURFACE DOSE FOR MEGAVOLTAGE PHOTON BEAMS OUTSIDE THE TREATMENT FIELD
    STARKSCHALL, G
    STGEORGE, FJ
    ZELLMER, DL
    MEDICAL PHYSICS, 1982, 9 (04) : 632 - 632
  • [5] LIF SURFACE AND DEPTH DOSE MEASUREMENTS OF MEGAVOLTAGE PHOTON AND ELECTRON BEAMS
    KARTHA, M
    MACDONALD, JC
    ACTA RADIOLOGICA-THERAPY PHYSICS BIOLOGY, 1971, 10 (02): : 279 - +
  • [6] Reduction of the Skin Surface Dose for Megavoltage Photon Beams Passing Carbon Couch
    Tamura, M.
    Monzen, H.
    Matsumoto, K.
    Okumura, M.
    Nishimura, Y.
    MEDICAL PHYSICS, 2017, 44 (06) : 2945 - 2945
  • [7] Absorbed dose conversion factors for megavoltage photon beams
    Nutbrown, R
    Duane, S
    Shipley, D
    Thomas, R
    ADVANCED MONTE CARLO FOR RADIATION PHYSICS, PARTICLE TRANSPORT SIMULATION AND APPLICATIONS, 2001, : 299 - 304
  • [8] Surface dose measurements in and out of field: Implications for breast radiotherapy with megavoltage photon beams
    Lonski, Peta
    Ramachandran, Prabhakar
    Franich, Rick
    Kron, Tomas
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2017, 27 (04): : 318 - 323
  • [9] Investigation of the effects of a carbon-fiber tabletop on the surface dose and attenuation dose for megavoltage photon beams
    Gursoy, G.
    Eser, E.
    Yigitoglu, I
    Koc, H.
    Kahraman, F. C.
    Yamcicier, S.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2018, 16 (02): : 235 - 241
  • [10] VALIDITY OF TRANSITION-ZONE DOSIMETRY AT HIGH ATOMIC-NUMBER INTERFACES IN MEGAVOLTAGE PHOTON BEAMS
    DAS, IJ
    KASE, KR
    MEIGOONI, AS
    KHAN, FM
    WERNER, BL
    MEDICAL PHYSICS, 1990, 17 (01) : 10 - 16