Evaluating the effect of dose on reconstructed image quality in digital tomosynthesis

被引:0
|
作者
Kempston, Michael P.
Mainprize, James G.
Yaffe, Martin J.
机构
[1] Sunnybrook Hlth Sci Ctr, Toronto, ON M4N 3M5, Canada
[2] Univ Toronto, Dept Med Biophys, Toronto, ON, Canada
来源
关键词
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Breast tomosynthesis has the potential to improve lesion visibility and localization compared to conventional mammography. To be clinically useful, tomosynthesis must be able to achieve high image quality at acceptable radiation doses. Tomosynthesis data sets of simple low-contrast phantoms were acquired at varying dose levels. Image quality in the reconstructed volumes was analyzed by evaluating the voxel-to-voxel signal difference to noise ratio between a simulated lesion and the surrounding "tissue". Preliminary results indicate that image quality of small lesions is limited by scatter and reconstruction artifacts. In uniform backgrounds image quality appears to be quantum-noise limited, while in more complex backgrounds the structural noise tends to dominate.
引用
收藏
页码:490 / 497
页数:8
相关论文
共 50 条
  • [1] Digital breast tomosynthesis: Dose and image quality assessment
    Maldera, A.
    De Marco, P.
    Colombo, P. E.
    Origgi, D.
    Torresin, A.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 33 : 56 - 67
  • [2] Effect of Denoising on the Quality of Reconstructed Images in Digital Breast Tomosynthesis
    Vieira, Marcelo A. C.
    Bakic, Predrag R.
    Maidment, Andrew D. A.
    [J]. MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [3] EFFECT OF THE GLANDULAR COMPOSITION ON DIGITAL BREAST TOMOSYNTHESIS IMAGE QUALITY AND DOSE OPTIMISATION
    Marques, T.
    Ribeiro, A.
    Di Maria, S.
    Belchior, A.
    Cardoso, J.
    Matela, N.
    Oliveira, N.
    Janeiro, L.
    Almeida, P.
    Vaz, P.
    [J]. RADIATION PROTECTION DOSIMETRY, 2015, 165 (1-4) : 337 - 341
  • [4] Effect of acquisition parameters on image quality in digital tomosynthesis
    Deller, Timothy
    Jabri, Kadri N.
    Sabol, John M.
    [J]. MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510
  • [5] RELATIONSHIP BETWEEN RADIATION DOSE AND IMAGE QUALITY IN DIGITAL BREAST TOMOSYNTHESIS
    Alakhras, Maram M.
    Mello-Thoms, Claudia
    Bourne, Roger
    Rickard, Mary
    Diffey, Jennifer
    Brennan, Patrick C.
    [J]. RADIATION PROTECTION DOSIMETRY, 2017, 173 (04) : 351 - 360
  • [6] Preference study of reconstructed image quality in mammographic tomosynthesis
    Claus, BEH
    Eberhard, JW
    Thomas, JA
    Galbo, CE
    Pakenas, WP
    Muller, SL
    [J]. DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2003, : 517 - 521
  • [7] Effect of angular range on image quality of chest digital tomosynthesis
    Lee, Haenghwa
    Kim, Ye-seul
    Choi, Sunghoon
    Lee, Dong-Hoon
    Choi, Seungyeon
    Kim, Hee-Joung
    [J]. MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [8] Evaluating the Effect of Acquisition Parameters in Digital Breast Tomosynthesis System with Iterative Reconstruction Methods on Image Quality
    Seyyedi, Saeed
    Yildirim, Isa
    Kamasak, Mustafa
    [J]. 2013 E-HEALTH AND BIOENGINEERING CONFERENCE (EHB), 2013,
  • [9] Image quality and dose assessment in digital breast tomosynthesis: A Monte Carlo study
    Baptista, M.
    Di Maria, S.
    Oliveira, N.
    Matela, N.
    Janeiro, L.
    Almeida, P.
    Vaz, P.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2014, 104 : 158 - 162
  • [10] Dose and diagnostic image quality in digital tomosynthesis imaging of facial bones in pediatrics
    King, J. M.
    Hickling, S.
    Elbakri, I. A.
    Reed, M.
    Wrogemann, J.
    [J]. MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961