Effect of acquisition parameters on image quality in digital tomosynthesis

被引:7
|
作者
Deller, Timothy [1 ]
Jabri, Kadri N. [1 ]
Sabol, John M. [1 ]
机构
[1] GE Healthcare Technologies, 3000 N Grandview Blvd, Waukesha, WI 53188 USA
关键词
tomosynthesis; digital radiography; volumetric imaging; image quality; acquisition parameters; ripple; resolution; image noise;
D O I
10.1117/12.713777
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Digital tomosynthesis (DTS) is emerging as an advanced imaging technique that enables volumetric slice imaging with a detector typically used for projection radiography. An understanding of the interactions between DTS acquisition. parameters and characteristics of the reconstructed slice images is required for optimizing the acquisition protocols of various clinical applications. This paper presents our.investigation of the effects and interactions of acquisition parameters, including sweep angle, number of projections, and dose, on clinically relevant image-quality metrics. Metrics included the image characteristics of in-slice resolution, depth resolution, image noise level, and presence of ripple. Phantom experiments were performed to characterize the relationship between the acquisition parameters and image quality. Results showed that the depth resolution was mainly dependent on sweep angle. Visibility of ripple was determined by the projection density (number of projections divided by sweep angle), as well as properties of the imaged object. Image noise was primarily dependent on total dose and not significantly affected by the number of projections. These experimental and theoretical results were confirmed using anthropomorphic phantoms and also used to develop clinical acquisition protocols. Assessment of phantom and clinical images obtained with these protocols revealed that the use of acquisition protocols optimized for a given clinical exam enables rapid, low-dose, high quality DTS imaging for diverse clinical applications including abdomen, hand, shoulder, spine, and chest. We conclude that DTS acquisition parameters have a significant effect on image quality and should be tailored for the imaged anatomy and desired clinical application. Relationships developed in this work will guide the selection of acquisition protocols to improve image quality and clinical utility of DTS for a wide variety of clinical exams.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Evaluating the Effect of Acquisition Parameters in Digital Breast Tomosynthesis System with Iterative Reconstruction Methods on Image Quality
    Seyyedi, Saeed
    Yildirim, Isa
    Kamasak, Mustafa
    [J]. 2013 E-HEALTH AND BIOENGINEERING CONFERENCE (EHB), 2013,
  • [2] Evaluating the effect of dose on reconstructed image quality in digital tomosynthesis
    Kempston, Michael P.
    Mainprize, James G.
    Yaffe, Martin J.
    [J]. DIGITAL MAMOGRAPHY, PROCEEDINGS, 2006, 4046 : 490 - 497
  • [3] Influence of the Acquisition Parameters on the Image Quality in Digital Mammography
    Al Kattar, Zeina
    El Balaa, Hanna
    Harb, Huda
    Raad, Nisrine
    Hodroj, Noor
    Sleiman, Fatina
    Omayrat, Samia
    [J]. 2015 INTERNATIONAL CONFERENCE ON ADVANCES IN BIOMEDICAL ENGINEERING (ICABME), 2015, : 33 - 36
  • [4] Effect of angular range on image quality of chest digital tomosynthesis
    Lee, Haenghwa
    Kim, Ye-seul
    Choi, Sunghoon
    Lee, Dong-Hoon
    Choi, Seungyeon
    Kim, Hee-Joung
    [J]. MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [5] Image Reconstruction Quality and Parameters in Tomosynthesis
    Ustinov A.O.
    Dabagov A.R.
    Karpov S.S.
    Nechaev V.A.
    [J]. Biomedical Engineering, 2018, 52 (4) : 280 - 283
  • [6] Digital breast tomosynthesis: Image acquisition principles and artifacts
    Sujlana, Parvinder S.
    Mahesh, Mahadevappa
    Vedantham, Srinivasan
    Harvey, Susan C.
    Mullen, Lisa A.
    Woods, Ryan W.
    [J]. CLINICAL IMAGING, 2019, 55 : 188 - 195
  • [7] A Novel Acquisition Scheme for Higher Axial Resolution and Improved Image Quality in Digital Tomosynthesis
    Levakhina, Y. M.
    Duschka, R. L.
    Vogt, F. M.
    Barkhausen, J.
    Buzug, T. M.
    [J]. BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2012, 57 : 111 - 114
  • [8] Optimization of exposure parameters in digital tomosynthesis considering effective dose and image quality
    Choi, Seungyeon
    Choi, Sunghoon
    Kim, Ye-seul
    Lee, Haenghwa
    Lee, Donghoon
    Jeon, Pil-Hyun
    Jang, Dong-Hyuk
    Kim, Hee-Joung
    [J]. MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [9] Influence of Tomographic Parameters on the Image Quality of Digital X-ray Tomosynthesis
    Oh, J. E.
    Cho, H. S.
    Choi, S. I.
    Kim, K. Y.
    Lee, S. Y.
    Lee, B. S.
    Kim, S.
    [J]. JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2008, : 451 - 454
  • [10] Evaluation of image quality in megavoltage digital tomosynthesis
    Descovich, M.
    Morin, O.
    Aubry, J.
    Aubin, M.
    Chen, H.
    Chen, J.
    Bani-Hashemi, A.
    Geffen, M.
    Kelly, K.
    Pang, G.
    Pouliot, J.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2281 - 2281