Effect of angular range on image quality of chest digital tomosynthesis

被引:0
|
作者
Lee, Haenghwa [1 ]
Kim, Ye-seul [1 ]
Choi, Sunghoon [1 ]
Lee, Dong-Hoon [2 ]
Choi, Seungyeon [2 ]
Kim, Hee-Joung [1 ,2 ]
机构
[1] Yonsei Univ, Coll Hlth Sci, Dept Radiol Sci, Seoul 120749, South Korea
[2] Yonsei Univ, Dept Radiat Convergence Engn, Res Inst Hlth Sci, Seoul 120749, South Korea
关键词
Chest digital tomosynthesis (CDT); angular range; contrast-to-noise (CNR); artifact spread function (ASF); point spread function (PSF); modulation transfer function (MTF); BREAST TOMOSYNTHESIS; OPTIMIZATION; PARAMETERS; GEOMETRY;
D O I
10.1117/12.2216842
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Chest digital tomosynthesis (CDT) is a new 3D imaging technique that can be expected to improve clinical diagnosis over conventional chest radiography. We investigated the effect of the angular range of data acquisition on the image quality using newly developed CDT system. The four different acquisition sets were studied using 15, 20, 30, and 35 angular ranges with 21 projection views (PVs). The point spread function (PSF), modulation transfer function (MTF), artifact spread function (ASF), and normalized contrast-to-noise ratio (CNR) were used to evaluate the image quality. We found that increasing angular ranges improved vertical resolution. The results indicated that there was the opposite relationship of the CNR with angular range for the two tissue types. While CNR for heart tissue increased with increasing angular range, CNR for spine bone decreased. The results showed that the angular range is an important parameter for the CDT exam.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Digital tomosynthesis mammography (DTM): Dependence of reconstruction image quality on number and angular range of projection views
    Chan, H-P
    Zhang, Y.
    Roubidoux, M. A.
    Helvie, M. A.
    Goodsitt, M. M.
    Carson, P.
    Sahiner, B.
    Hadjinski, L.
    Wei, J.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2001 - 2001
  • [2] Effect of acquisition parameters on image quality in digital tomosynthesis
    Deller, Timothy
    Jabri, Kadri N.
    Sabol, John M.
    [J]. MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510
  • [3] The Effect of Dose Reduction on Overall Image Quality in Clinical Chest Tomosynthesis
    Mirzai, Maral
    Meltzer, Carin
    Vikgren, Jenny
    Norrlund, Rauni Rossi
    Gottfridsson, Bengt
    Johnsson, Ase
    Bath, Magnus
    Svalkvist, Angelica
    [J]. ACADEMIC RADIOLOGY, 2021, 28 (10) : E289 - E296
  • [4] Evaluating the effect of dose on reconstructed image quality in digital tomosynthesis
    Kempston, Michael P.
    Mainprize, James G.
    Yaffe, Martin J.
    [J]. DIGITAL MAMOGRAPHY, PROCEEDINGS, 2006, 4046 : 490 - 497
  • [5] Comparison study of image quality and effective dose in dual energy chest digital tomosynthesis
    Lee, Donghoon
    Choi, Sunghoon
    Lee, Haenghwa
    Kim, Dohyeon
    Choi, Seungyeon
    Kim, Hee-Joung
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2018, 148 : 112 - 120
  • [6] Digital tomosynthesis of the chest
    Dobbins, James T., III
    McAdams, H. Page
    Godfrey, Devon J.
    Li, Christina M.
    [J]. JOURNAL OF THORACIC IMAGING, 2008, 23 (02) : 86 - 92
  • [7] Evaluation of image quality in megavoltage digital tomosynthesis
    Descovich, M.
    Morin, O.
    Aubry, J.
    Aubin, M.
    Chen, H.
    Chen, J.
    Bani-Hashemi, A.
    Geffen, M.
    Kelly, K.
    Pang, G.
    Pouliot, J.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2281 - 2281
  • [8] Effect of acquisition parameters on digital breast tomosynthesis: Total angular range and number of projection views
    Choi, Young-Wook
    Park, Hye-Suk
    Kim, Ye-seul
    Kim, Hee-Joung
    Choi, Jae-Gu
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2012, 61 (11) : 1877 - 1883
  • [9] Effect of acquisition parameters on digital breast tomosynthesis: Total angular range and number of projection views
    Young-Wook Choi
    Hye-Suk Park
    Ye-seul Kim
    Hee-Joung Kim
    Jae-Gu Choi
    [J]. Journal of the Korean Physical Society, 2012, 61 : 1877 - 1883
  • [10] Insight into digital tomosynthesis of the chest
    Lacout, A.
    El Hajjam, M.
    Marcy, P. -Y.
    [J]. FEUILLETS DE RADIOLOGIE, 2013, 53 (03) : 135 - 142