Evaluating the Effect of Acquisition Parameters in Digital Breast Tomosynthesis System with Iterative Reconstruction Methods on Image Quality

被引:0
|
作者
Seyyedi, Saeed [1 ]
Yildirim, Isa [1 ]
Kamasak, Mustafa [2 ]
机构
[1] Istanbul Tech Univ, Dept Elect & Elect Engn, TR-80626 Istanbul, Turkey
[2] Istanbul Tech Univ, Dept Comp Engn, Istanbul, Turkey
关键词
Digital breast tomosynthesis; angular projections; angular span;
D O I
10.1109/EHB.2013.6707316
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Digital breast tomosynthesis (DBT) is a promising imaging modality that provides a 3D reconstructed object from 2D projections acquired over a limited angular range. The diagnostic quality of tomosynthesis depends on multiple variables, each of which needs to be optimized. This study investigates the effects of number of angular projections and the total angular span of those projections on the reconstructed image quality of breast tomosynthesis system. 5 different acquisition sets are used considering the available DBT systems.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Effect of acquisition parameters on image quality in digital tomosynthesis
    Deller, Timothy
    Jabri, Kadri N.
    Sabol, John M.
    [J]. MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510
  • [2] Statistical iterative reconstruction to improve image quality for digital breast tomosynthesis
    Xu, Shiyu
    Lu, Jianping
    Zhou, Otto
    Chen, Ying
    [J]. MEDICAL PHYSICS, 2015, 42 (09) : 5377 - 5390
  • [3] Convergence of iterative image reconstruction algorithms for Digital Breast Tomosynthesis
    Sidky, Emil Y.
    Jprgensen, Jakob H.
    Pan, Xiaochuan
    [J]. 2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 3394 - 3396
  • [4] ITERATIVE BREAST TOMOSYNTHESIS IMAGE RECONSTRUCTION
    Bustamante, Veronica Mejia
    Nagy, James G.
    Feng, Steve S. J.
    Sechopoulos, Ioannis
    [J]. SIAM JOURNAL ON SCIENTIFIC COMPUTING, 2013, 35 (05): : S192 - S208
  • [5] Image artifact in digital breast tomosynthesis and its dependence on system and reconstruction parameters
    Hu, Yue-Houng
    Zhao, Wei
    Mertelmeier, Thomas
    Ludwig, Jasmina
    [J]. DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2008, 5116 : 628 - +
  • [6] Effect of Reconstruction Methods On the Evaluation of Digital Breast Tomosynthesis (DBT) Acquisition Parameters Using Human and Model Observers
    Zeng, R.
    Park, S.
    Badano, A.
    Myers, K.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3611 - 3611
  • [7] Enhancing tissue structures with iterative image reconstruction for digital breast tomosynthesis
    Sidky, Emil Y.
    Reiser, Ingrid S.
    Nishikawa, Robert M.
    Pan, Xiaochuan
    [J]. MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [8] Improving depth resolution in digital breast tomosynthesis by iterative image reconstruction
    Roth, Erin G.
    Kraemer, David N.
    Sidky, Emil Y.
    Reiser, Ingrid S.
    Pan, Xiaochun
    [J]. MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [9] Dependency of image quality on system configuration parameters in a stationary digital breast tomosynthesis system
    Tucker, Andrew W.
    Lu, Jianping
    Zhou, Otto
    [J]. MEDICAL PHYSICS, 2013, 40 (03)
  • [10] Study of Image Quality in Digital Breast Tomosynthesis by Subpixel Reconstruction
    Lu, Yao
    Chan, Heang-Ping
    Wei, Jun
    Hadjiiski, Lubomir
    Samala, Ravi
    [J]. MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668