Evaluating the effect of dose on reconstructed image quality in digital tomosynthesis

被引:0
|
作者
Kempston, Michael P.
Mainprize, James G.
Yaffe, Martin J.
机构
[1] Sunnybrook Hlth Sci Ctr, Toronto, ON M4N 3M5, Canada
[2] Univ Toronto, Dept Med Biophys, Toronto, ON, Canada
来源
关键词
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Breast tomosynthesis has the potential to improve lesion visibility and localization compared to conventional mammography. To be clinically useful, tomosynthesis must be able to achieve high image quality at acceptable radiation doses. Tomosynthesis data sets of simple low-contrast phantoms were acquired at varying dose levels. Image quality in the reconstructed volumes was analyzed by evaluating the voxel-to-voxel signal difference to noise ratio between a simulated lesion and the surrounding "tissue". Preliminary results indicate that image quality of small lesions is limited by scatter and reconstruction artifacts. In uniform backgrounds image quality appears to be quantum-noise limited, while in more complex backgrounds the structural noise tends to dominate.
引用
收藏
页码:490 / 497
页数:8
相关论文
共 50 条
  • [41] Evaluating phantom image quality parameters to optimise patient radiation dose in dental digital radiology
    Gonzalez, Luciano
    Vano, Eliseo
    Fernandez, Ramon
    Ziraldo, Viviana
    Delgado, Jaime
    Delgado, Victor
    Moro, Javier
    Ubeda, Carlos
    [J]. RADIATION PROTECTION DOSIMETRY, 2012, 151 (01) : 95 - 101
  • [42] The effect of angular dose distribution on the detection of microcalcifications in digital breast tomosynthesis
    Hu, Yue-Houng
    Zhao, Wei
    [J]. MEDICAL PHYSICS, 2011, 38 (05) : 2455 - 2466
  • [43] Optimization of Image Quality and Dose in Digital Mammography
    Fausto, Agnes M. F.
    Lopes, M. C.
    de Sousa, M. C.
    Furquim, Tania A. C.
    Mol, Anderson W.
    Velasco, Fermin G.
    [J]. JOURNAL OF DIGITAL IMAGING, 2017, 30 (02) : 185 - 196
  • [44] Optimization of Image Quality and Dose in Digital Mammography
    Agnes M. F. Fausto
    M. C. Lopes
    M. C. de Sousa
    Tânia A. C. Furquim
    Anderson W. Mol
    Fermin G. Velasco
    [J]. Journal of Digital Imaging, 2017, 30 : 185 - 196
  • [45] DIGITAL RADIOGRAPHY: IMAGE QUALITY AND RADIATION DOSE
    Seibert, J. Anthony
    [J]. HEALTH PHYSICS, 2008, 95 (05): : 586 - 598
  • [46] Effects of Reduced Compression in Digital Breast Tomosynthesis on Pain, Anxiety, and Image Quality
    Suhaimi, Siti Aishah Abdullah
    Mohamed, Afifah
    Ahmad, Mahadir
    Chelliah, Kanaga Kumari
    [J]. MALAYSIAN JOURNAL OF MEDICAL SCIENCES, 2015, 22 (06): : 40 - 46
  • [47] The effect of digital image manipulation on patient dose utilizing threshold contrast as a measure of image quality
    Hintenlang, DE
    Arreola, MM
    Pitcher, CD
    [J]. HEALTH PHYSICS, 2003, 84 (06): : S261 - S261
  • [48] Simulation of the Effect of Noise on Terahertz Digital Holography Reconstructed Image
    Lin, Ping
    Li, Qi
    Shen, Zuochun
    [J]. 14TH NATIONAL CONFERENCE ON LASER TECHNOLOGY AND OPTOELECTRONICS (LTO 2019), 2019, 11170
  • [49] In-plane image quality and NPWE detectability index in digital breast tomosynthesis
    Monnin, P.
    Verdun, F. R.
    Bosmans, H.
    Marshall, N. W.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (09):
  • [50] Variation in digital breast tomosynthesis image quality at differing heights above the detector
    Davidson, Rob
    Al Khalifah, Khaled
    Zhou, Abel
    [J]. JOURNAL OF MEDICAL RADIATION SCIENCES, 2022, 69 (02) : 174 - 181