The effect of angular dose distribution on the detection of microcalcifications in digital breast tomosynthesis

被引:34
|
作者
Hu, Yue-Houng [1 ]
Zhao, Wei [1 ]
机构
[1] SUNY Stony Brook, Dept Radiol, Stony Brook, NY 11794 USA
关键词
tomosynthesis; breast imaging; microcalcifications; linear-system model; ideal observer; MTF; NPS; detectability; AMORPHOUS SELENIUM; IMAGING PERFORMANCE; MAMMOGRAPHY; VALIDATION; OBSERVER; MODEL; TASK; MTF;
D O I
10.1118/1.3570580
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Substantial effort has been devoted to the clinical development of digital breast tomosynthesis (DBT). DBT is a three-dimensional (3D) x-ray imaging modality that reconstructs a number of thin image slices parallel to a stationary detector plane. Preliminary clinical studies have shown that the removal of overlapping breast tissue reduces image clutter and increases detectability of large, low contrast lesions. However, some studies, as well as anecdotal evidence, suggested decreased conspicuity of small, high contrast objects such as microcalcifications. Several investigators have proposed alternative imaging methods for improving microcalcification detection by delivering half of the total dose to the central view in addition to a separate DBT scan. Preliminary observer studies found possible improvement by either viewing the central projection alone or combining all views with a reconstruction algorithm. Methods: In this paper, we developed a generalized imaging theory based on a cascaded linear-system model for DBT to calculate the effect of variable angular dose distribution on the 3D modulation transfer function (MTF) and noise power spectrum (NPS). Using the ideal observer signal-to-noise ratio (SNR), d', as a figure-of-merit (FOM) for a signal embedded in a uniform background, we compared the detectability of objects with different sizes under different imaging conditions (e.g., angular dose distribution and reconstruction filters). Experimental investigation was conducted for three different angular dose schemes (ADS) using a Siemens Novation(TOMO) prototype unit. Results: Our results show excellent agreement between modeled and experimental measurements of 3D NPS with different angular dose distribution. The ideal observer detectability index for the detection of Gaussian objects with different angular dose distributions depends strongly on the applied reconstruction filter as well as the imaging task. For detection tasks of small calcifications with reconstruction filters used typically in a clinical setting, variable angular dose distribution with more dose delivered to the central views may lead to higher d' than a uniform angular dose distribution. Conclusions: The conspicuity of the detection of small calcifications may be improved, under certain imaging conditions, by delivering higher dose toward the central views of a tomosynthesis scan, while also reducing the dose at peripheral angles to keep total administered radiation dose equivalent. The degree of improvement depends on the choice of reconstruction filters as well as the imaging task. The improvement is more substantial for high-frequency imaging tasks and when an aggressive slice-thickness (ST) filter is applied to reduced the high-frequency noise at peripheral angles. (C) 2011 American Association of Physicists in Medicine. [DOI: 10.1118/1.3570580]
引用
收藏
页码:2455 / 2466
页数:12
相关论文
共 50 条
  • [1] Effect of Dose Level on Radiologists' Detection of Microcalcifications in Digital Breast Tomosynthesis: An Observer Study with Breast Phantoms
    Chan, Heang-Ping
    Helvie, Mark A.
    Klein, Katherine A.
    McLaughlin, Carol
    Neal, Colleen H.
    Oudsema, Rebecca
    Rahman, W. Tania
    Roubidoux, Marilyn A.
    Hadjiiski, Lubomir M.
    Zhou, Chuan
    Samala, Ravi K.
    [J]. ACADEMIC RADIOLOGY, 2022, 29 : S42 - S49
  • [2] Microcalcifications in the breast and digital tomosynthesis
    Boisserie-Lacroix, Martine
    Ziade, Caroline
    Hurtevent-Labrot, Gabrielle
    Ferron, Stephane
    Depetiteville, Marie-Pierre
    [J]. IMAGERIE DE LA FEMME, 2016, 26 (3-4) : 157 - 159
  • [3] Classification of Clusters of Microcalcifications in Digital Breast Tomosynthesis
    Ho, Candy P. S.
    Tromans, Christopher
    Schnabel, Julia A.
    Brady, Michael
    [J]. 2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 3166 - 3169
  • [4] Comparison of synthetic and digital mammography with digital breast tomosynthesis or alone for the detection and classification of microcalcifications
    Choi, Ji Soo
    Han, Boo-Kyung
    Ko, Eun Young
    Kim, Ga Ram
    Ko, Eun Sook
    Park, Ko Woon
    [J]. EUROPEAN RADIOLOGY, 2019, 29 (01) : 319 - 329
  • [5] Comparison of synthetic and digital mammography with digital breast tomosynthesis or alone for the detection and classification of microcalcifications
    Ji Soo Choi
    Boo-Kyung Han
    Eun Young Ko
    Ga Ram Kim
    Eun Sook Ko
    Ko Woon Park
    [J]. European Radiology, 2019, 29 : 319 - 329
  • [6] Digital breast tomosynthesis improves diagnostic accuracy of breast microcalcifications
    Liu, Weimin
    Long, Meijun
    Peng, Lingrong
    Qu, Caihong
    Guo, Ruomi
    Kang, Zhuang
    Wang, Jin
    Wu, Juekun
    Wang, Xiaohong
    [J]. INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 2021, 31 (02) : 555 - 561
  • [7] Detection of lung nodules in chest digital tomosynthesis (CDT) : effects of the different angular dose distribution
    Jo, Byungdu
    Lee, Youngjin
    Kim, Dohyeon
    Lee, Dong-Hoon
    Jin, Seong-Soo
    Mu, Shou-Chih
    Kim, Hye-Mi
    Kim, Hee-Joung
    [J]. MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [8] Strategies of improving lesion detection in wide-angle digital breast tomosynthesis (DBT) with angular dose distribution and detector design
    Duan, Xiaoyu
    Huang, Hailiang
    Zhao, Wei
    [J]. MEDICAL IMAGING 2021: PHYSICS OF MEDICAL IMAGING, 2021, 11595
  • [9] Comparison of computer-aided detection of clustered microcalcifications in digital mammography and digital breast tomosynthesis
    Samala, Ravi K.
    Chan, Heang-Ping
    Lu, Yao
    Hadjiiski, Lubomir
    Wei, Jun
    Helvie, Mark
    [J]. MEDICAL IMAGING 2015: COMPUTER-AIDED DIAGNOSIS, 2015, 9414
  • [10] Deep learning denoising of digital breast tomosynthesis: Observer performance study of the effect on detection of microcalcifications in breast phantom images
    Chan, Heang-Ping
    Helvie, Mark A.
    Gao, Mingjie
    Hadjiiski, Lubomir
    Zhou, Chuan
    Garver, Kim
    Klein, Katherine A.
    McLaughlin, Carol
    Oudsema, Rebecca
    Rahman, W. Tania
    Roubidoux, Marilyn A.
    [J]. MEDICAL PHYSICS, 2023, 50 (10) : 6177 - 6189