The effect of angular dose distribution on the detection of microcalcifications in digital breast tomosynthesis

被引:34
|
作者
Hu, Yue-Houng [1 ]
Zhao, Wei [1 ]
机构
[1] SUNY Stony Brook, Dept Radiol, Stony Brook, NY 11794 USA
关键词
tomosynthesis; breast imaging; microcalcifications; linear-system model; ideal observer; MTF; NPS; detectability; AMORPHOUS SELENIUM; IMAGING PERFORMANCE; MAMMOGRAPHY; VALIDATION; OBSERVER; MODEL; TASK; MTF;
D O I
10.1118/1.3570580
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Substantial effort has been devoted to the clinical development of digital breast tomosynthesis (DBT). DBT is a three-dimensional (3D) x-ray imaging modality that reconstructs a number of thin image slices parallel to a stationary detector plane. Preliminary clinical studies have shown that the removal of overlapping breast tissue reduces image clutter and increases detectability of large, low contrast lesions. However, some studies, as well as anecdotal evidence, suggested decreased conspicuity of small, high contrast objects such as microcalcifications. Several investigators have proposed alternative imaging methods for improving microcalcification detection by delivering half of the total dose to the central view in addition to a separate DBT scan. Preliminary observer studies found possible improvement by either viewing the central projection alone or combining all views with a reconstruction algorithm. Methods: In this paper, we developed a generalized imaging theory based on a cascaded linear-system model for DBT to calculate the effect of variable angular dose distribution on the 3D modulation transfer function (MTF) and noise power spectrum (NPS). Using the ideal observer signal-to-noise ratio (SNR), d', as a figure-of-merit (FOM) for a signal embedded in a uniform background, we compared the detectability of objects with different sizes under different imaging conditions (e.g., angular dose distribution and reconstruction filters). Experimental investigation was conducted for three different angular dose schemes (ADS) using a Siemens Novation(TOMO) prototype unit. Results: Our results show excellent agreement between modeled and experimental measurements of 3D NPS with different angular dose distribution. The ideal observer detectability index for the detection of Gaussian objects with different angular dose distributions depends strongly on the applied reconstruction filter as well as the imaging task. For detection tasks of small calcifications with reconstruction filters used typically in a clinical setting, variable angular dose distribution with more dose delivered to the central views may lead to higher d' than a uniform angular dose distribution. Conclusions: The conspicuity of the detection of small calcifications may be improved, under certain imaging conditions, by delivering higher dose toward the central views of a tomosynthesis scan, while also reducing the dose at peripheral angles to keep total administered radiation dose equivalent. The degree of improvement depends on the choice of reconstruction filters as well as the imaging task. The improvement is more substantial for high-frequency imaging tasks and when an aggressive slice-thickness (ST) filter is applied to reduced the high-frequency noise at peripheral angles. (C) 2011 American Association of Physicists in Medicine. [DOI: 10.1118/1.3570580]
引用
收藏
页码:2455 / 2466
页数:12
相关论文
共 50 条
  • [21] Angular dependence of mammographic dosimeters in digital breast tomosynthesis
    Bradley, Lena R.
    Carton, Ann-Katherine
    Maidment, Andrew D. A.
    [J]. MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [22] Computer-Aided Detection of Microcalcifications in Digital Breast Tomosynthesis (DBT): A Multichannel Signal Detection Approach on Projection Views
    Wei, Jun
    Chan, Heang-Ping
    Hadjiiski, Lubomir
    Helvie, Mark A.
    Zhou, Chuan
    Lu, Yao
    [J]. MEDICAL IMAGING 2012: COMPUTER-AIDED DIAGNOSIS, 2012, 8315
  • [23] Realistic Simulation of Microcalcifications in Breast Tomosynthesis
    Shaheen, Eman
    Van Ongeval, Chantal
    Cockmartin, Lesley
    Zanca, Federica
    Marshall, Nicholas
    Jacobs, Jurgen
    Bosmans, Hilde
    [J]. DIGITAL MAMMOGRAPHY, 2010, 6136 : 235 - 242
  • [24] Improved detection with digital breast tomosynthesis
    Focusing on industry and technology trends, Brooklyn, NY, United States
    [J]. Sci. Comput., 2007, 4 (27-29):
  • [25] Cancer Detection with Digital Breast Tomosynthesis
    Harris, Lisa Katherine
    Mai-Tran, Vivian
    Durand, Melissa
    [J]. CURRENT RADIOLOGY REPORTS, 2020, 8 (04)
  • [26] Cancer Detection with Digital Breast Tomosynthesis
    Lisa Katherine Harris
    Vivian Mai-Tran
    Melissa Durand
    [J]. Current Radiology Reports, 8
  • [27] PATIENT DOSE EVALUATION IN DIGITAL BREAST TOMOSYNTHESIS
    Kisielewicz, K.
    Rawojc, K.
    Dziubinska, A.
    Mazur, L.
    Kieltyka, B.
    Najberg-Pierzchala, D.
    Gadek, M.
    Luczynska, E.
    Wos, Z.
    Heinze, S.
    Dziecichowicz, A.
    [J]. ACTA PHYSICA POLONICA B, 2020, 51 (01): : 345 - 349
  • [28] Detection of microcalcifications in breast tomosynthesis reconstructed with multiscale bilateral filtering regularization
    Samala, Ravi K.
    Chan, Heang-Ping
    Lu, Yao
    Hadjiiski, Lubomir
    Wei, Jun
    Sahiner, Berkman
    Helvie, Mark
    [J]. MEDICAL IMAGING 2013: COMPUTER-AIDED DIAGNOSIS, 2013, 8670
  • [29] Simulation of Dose Reduction in Digital Breast Tomosynthesis
    Borges, Lucas R.
    Guerrero, Igor
    Bakic, Predrag R.
    Maidment, Andrew D. A.
    Schiabel, Homero
    Vieira, Marcelo A. C.
    [J]. BREAST IMAGING, IWDM 2016, 2016, 9699 : 343 - 350
  • [30] Selective-diffusion regularization for enhancement of microcalcifications in digital breast tomosynthesis reconstruction
    Lu, Yao
    Chan, Heang-Ping
    Wei, Jun
    Hadjiiski, Lubomir M.
    [J]. MEDICAL PHYSICS, 2010, 37 (11) : 6003 - 6014