Preference study of reconstructed image quality in mammographic tomosynthesis

被引:0
|
作者
Claus, BEH [1 ]
Eberhard, JW [1 ]
Thomas, JA [1 ]
Galbo, CE [1 ]
Pakenas, WP [1 ]
Muller, SL [1 ]
机构
[1] GE Global Res Ctr, Niskayuna, NY 12309 USA
关键词
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Digital tomosynthesis mammography is an advanced x-ray application that provides detailed 3D information about the imaged breast. The involved 3D reconstruction step is a difficult problem due to incomplete data and the limited projection angle. In this preference study we compared results obtained with advanced reconstruction techniques, in particular ART (Algebraic Reconstruction Technique), FBP (Filtered Backprojection), OSBP (order statistics based backprojection), and GFBP (generalized filtered backprojection) in terms of their image quality. The 3D datasets were displayed slice-by-slice in "cine loop" mode. As observers we included radiologists, physicists and image processing experts. Phantom and mastectomy specimen datasets were included in the study. The results obtained with our dataset indicate that ART was overall preferred for the phantom datasets while GFBP was preferred for mastectomy specimen reconstructions.
引用
收藏
页码:517 / 521
页数:5
相关论文
共 50 条
  • [1] Evaluating the effect of dose on reconstructed image quality in digital tomosynthesis
    Kempston, Michael P.
    Mainprize, James G.
    Yaffe, Martin J.
    [J]. DIGITAL MAMOGRAPHY, PROCEEDINGS, 2006, 4046 : 490 - 497
  • [2] Study of digital mammographic equipments by phantom image quality
    Mayo, P.
    Rodenas, F.
    Verdu, G.
    Campayo, J. M.
    Villaescusa, J. I.
    [J]. 2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 1845 - +
  • [3] IMAGE QUALITY OF MAMMOGRAPHIC SYSTEMS
    KARILA, KTK
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 1987, 7 (03) : 194 - 198
  • [4] Study of Image Quality in Digital Breast Tomosynthesis by Subpixel Reconstruction
    Lu, Yao
    Chan, Heang-Ping
    Wei, Jun
    Hadjiiski, Lubomir
    Samala, Ravi
    [J]. MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [5] Image Registration for Detection and Quantification of Change on Digital Tomosynthesis Mammographic Volumes
    Sinha, Sumedha P.
    Narayanan, Ramkrishnan
    Ma, Bing
    Roubidoux, Marilyn A.
    Liu, He
    Carson, Paul L.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (02) : 384 - 387
  • [6] Effect of Denoising on the Quality of Reconstructed Images in Digital Breast Tomosynthesis
    Vieira, Marcelo A. C.
    Bakic, Predrag R.
    Maidment, Andrew D. A.
    [J]. MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [7] Image quality measurements in breast tomosynthesis
    van Engen, Ruben
    Bouwman, Ramona
    van der Burght, Roeland
    Lazzari, Barbara
    Dance, David R.
    Heid, Patrice
    Aslund, Magnus
    Young, Kenneth C.
    [J]. DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2008, 5116 : 696 - +
  • [8] Image Reconstruction Quality and Parameters in Tomosynthesis
    Ustinov A.O.
    Dabagov A.R.
    Karpov S.S.
    Nechaev V.A.
    [J]. Biomedical Engineering, 2018, 52 (4) : 280 - 283
  • [9] Image Quality Evaluation of Breast Tomosynthesis
    Andria, G.
    Attivissimo, F.
    Di Nisio, A.
    Lanzoa, A. M. L.
    Spadavecchia, M.
    [J]. 2016 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2016, : 143 - 148
  • [10] ASSESSING ADEQUACY OF MAMMOGRAPHIC IMAGE QUALITY
    EKLUND, GW
    CARDENOSA, G
    PARSONS, W
    [J]. RADIOLOGY, 1994, 190 (02) : 297 - 307