Spin-echo T1-weighted Imaging of the Brain with Interleaved Acquisition and Presaturation Pulse at 3 T: A Feasibility Study Before Clinical Use

被引:3
|
作者
Kasahara, Seiko [1 ]
Miki, Yukio [1 ]
Mori, Nobuyuki [1 ]
Urayama, Shin-ichi [2 ]
Kanagaki, Mitsunori [1 ]
Fushimi, Yasutaka [3 ]
Maeda, Chikara [1 ]
Sawamoto, Nobukatsu [2 ]
Fukuyama, Hidenao [2 ]
Togashi, Kaori [1 ]
机构
[1] Kyoto Univ, Dept Diagnost Imaging & Nucl Med, Sakyo Ku, Kyoto 6068507, Japan
[2] Kyoto Univ, Grad Sch Med, Human Brain Res Ctr, Sakyo Ku, Kyoto 6068507, Japan
[3] Hikone Municipal Hosp, Dept Radiol, Shiga, Japan
关键词
Spin-echo sequence; T1-weighted image; brain; 3; T; ATTENUATED INVERSION-RECOVERY; WHITE MATTER CONTRAST; HIGH FIELD MRI; MAGNETIC-RESONANCE; MACROSCOPIC SUSCEPTIBILITY; ARTIFACTS; STRENGTH; IMAGES; TIME;
D O I
10.1016/j.acra.2008.12.026
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. Although spin-echo (SE) sequence has some advantages over gradient-echo sequence in brain imaging, gradient-echo sequence is commonly used For T1-weighted imaging (T1WI) at 3 T because contrast on SE T1WI is widely believed to be poor at 3 T. Recently, gray-white matter contrast on single-slice and multi-slice SE imaging with interslice gap was reported as better at 3 T than at 1.5 T. This Study examined the feasibility of interleaved SE T1WI of the brain at 3 T. This study also examined whether presaturation pulse (PP) sufficiently suppresses intra-arterial signals because these signals tend to be hyperintense due to longer T1 at 3 T. Materials and Methods. Subjects consisted of 18 healthy volunteers. Two sets of T1WI were performed using SE sequence. One set consisted of imaging without PP, and the other consisted of imaging with PP. Each set contained three types of gapless imaging as follows; sequential, 100% interleaved, and 200% interleaved imaging. In each subject, contrast-to-noise ratio between gray-matter and white-matter (CNRGM-WM) and intra-arterial signals were evaluated. Results. CNRGM-WM was significantly higher on interleaved images than on sequential images, regardless of PP (P < .0001). PP sufficiently suppressed intra-arterial signals (P < .0001). Conclusion. CNRGM-WM On SE T1WI at 3 T can be improved by interleaved acquisition, and PP sufficiently suppressed intra-arterial signals. Interleaved SE T1WI with PP appears clinically feasible at 3 T.
引用
收藏
页码:852 / 857
页数:6
相关论文
共 50 条
  • [21] Comparison of turbo inversion recovery magnitude (TIRM) with T2-weighted turbo spin-echo and T1-weighted spin-echo MR imaging in the early diagnosis of acute osteomyelitis in children
    Hauer, MP
    Uhl, M
    Allmann, HK
    Laubenberger, J
    Zimmerhackl, LB
    Langer, M
    PEDIATRIC RADIOLOGY, 1998, 28 (11) : 846 - 850
  • [22] Comparison of turbo inversion recovery magnitude (TIRM) with T2-weighted turbo spin-echo and T1-weighted spin-echo MR imaging in the early diagnosis of acute osteomyelitis in children
    M. P. Hauer
    Markus Uhl
    Karl-Heinz Allmann
    Jörg Laubenberger
    Lothar B. Zimmerhackl
    Mathias Langer
    Pediatric Radiology, 1998, 28 : 846 - 850
  • [23] Artifact reduction from metallic dental materials in T1-weighted spin-echo imaging at 3.0 tesla
    Zho, Sang-Young
    Kim, Min-Oh
    Lee, Keun-Woo
    Kim, Dong-Hyun
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 37 (02) : 471 - 478
  • [24] Gray matter-white matter contrast on spin-echo T1-weighted images at 3 T and 1.5 T: a quantitative comparison study
    Yasutaka Fushimi
    Yukio Miki
    Shin-ichi Urayama
    Tsutomu Okada
    Nobuyuki Mori
    Takashi Hanakawa
    Hidenao Fukuyama
    Kaori Togashi
    European Radiology, 2007, 17 (11) : 2921 - 2925
  • [25] Magnetic resonance imaging of the brain with gadopentetate dimeglumine-DTPA: Comparison of T1-weighted spin-echo and 3D gradient-echo sequences
    Li, DB
    Haacke, EM
    Tarr, RW
    Venkatesan, R
    Lin, WL
    Wielopolski, P
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (03): : 415 - 424
  • [26] CLINICAL UTILITY OF PARTIAL FLIP ANGLE T2-WEIGHTED SPIN-ECHO IMAGING OF THE BRAIN
    CHANG, KH
    YI, JG
    HAN, MH
    CHO, MH
    HAN, MC
    CHO, ZH
    KIM, CW
    NEURORADIOLOGY, 1990, 32 (04) : 255 - 260
  • [27] Contrast-enhanced MR imaging of the brain using T1-weighted FLAIR with BLADE compared with a conventional spin-echo sequence
    Shinji Naganawa
    Hiroko Satake
    Shingo Iwano
    Hisashi Kawai
    Seiji Kubota
    Tomohiro Komada
    Minako Kawamura
    Yasuo Sakurai
    Hiroshi Fukatsu
    European Radiology, 2008, 18
  • [28] Contrast-enhanced MR imaging of the brain using T1-weighted FLAIR with BLADE compared with a conventional spin-echo sequence
    Naganawa, Shinji
    Satake, Hiroko
    Iwano, Shingo
    Kawai, Hisashi
    Kubota, Seiji
    Komada, Tomohiro
    Kawamura, Minako
    Sakurai, Yasuo
    Fukatsu, Hiroshi
    EUROPEAN RADIOLOGY, 2008, 18 (02) : 337 - 342
  • [29] PATHOLOGY OF THE MEMBRANOUS LABYRINTH - COMPARISON OF T1-WEIGHTED AND T2-WEIGHTED AND GADOLINIUM-ENHANCED SPIN-ECHO AND 3DFT-CISS IMAGING
    CASSELMAN, JW
    KUHWEIDE, R
    AMPE, W
    MEEUS, L
    STEYAERT, L
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1993, 14 (01) : 59 - 69
  • [30] Optimized T1-weighted contrast for single-slab 3D turbo spin-echo imaging with long echo trains:: Application to whole-brain imaging
    Park, Jaeseok
    Mugler, John P., III
    Horger, Wilhelm
    Kiefer, Berthold
    MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (05) : 982 - 992