Comparison of turbo inversion recovery magnitude (TIRM) with T2-weighted turbo spin-echo and T1-weighted spin-echo MR imaging in the early diagnosis of acute osteomyelitis in children

被引:23
|
作者
Hauer, MP
Uhl, M
Allmann, HK
Laubenberger, J
Zimmerhackl, LB
Langer, M
机构
[1] Univ Freiburg, Radiol Univ Klin, Rontgendiagnost Abt, D-79106 Freiburg, Germany
[2] Univ Freiburg, Kinderklin, D-7800 Freiburg, Germany
关键词
D O I
10.1007/s002470050479
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Objective. To compare turbo inversion recovery magnitude (TIRM) with standard T1-weighted (T1-W) and T2-weighted (T2-W) MR sequences in the very early detection of acute osteomyelitis in children. Materials and methods. In 15 children with osteomyelitis, 15 sets of T1-W spin-echo (SE) (TR/TE, 400-640/12-17), T2-W turbo spin-echo (TSE) (TR/TE/ETL, 3290-4465/112-120/11), and TIRM (TR/TE/TI, 4000-6120/60/160) images were acquired with a 1.0-T magnet. Contrast-to-noise (C/N) ratios and percentage of signal between lesion and normal bone marrow were analysed with a computer-assisted image analysing system in a region of interest (ROI). Results. In 13 of 15 patients, the absolute signal enhancement in a ROI on the TIRM images was better than on the T1-W SE and T2-W TSE images and in 14 of 15 cases, C/N ratios were also better on the TIRM images than on the other sequences. In the other cases, the TIRM signal was diagnostically equivalent. On the TIRM images, the signal difference between normal and pathological tissue was increased to 43-281% (mean 124%). On the T2-W TSE images, this signal difference was 4-79% (mean 36%) and on the T1-W SE images 6-77% (mean 37%). Conclusion. The TIRM sequence is highly sensitive for detecting bone marrow oedema in the very early stage of acute osteomyelitis in children. MRI utilising the TIRM sequence allowed for an early diagnosis. With scan time of less than 4 minutes, this sequence is superior to T1-W SE and T2-W TSE images for detecting early osteomyelitis-associated bone marrow oedema.
引用
收藏
页码:846 / 850
页数:5
相关论文
共 50 条
  • [1] Comparison of turbo inversion recovery magnitude (TIRM) with T2-weighted turbo spin-echo and T1-weighted spin-echo MR imaging in the early diagnosis of acute osteomyelitis in children
    M. P. Hauer
    Markus Uhl
    Karl-Heinz Allmann
    Jörg Laubenberger
    Lothar B. Zimmerhackl
    Mathias Langer
    [J]. Pediatric Radiology, 1998, 28 : 846 - 850
  • [2] Comparison of conventional and turbo spin-echo T1-weighted MR imaging in acute knee trauma
    Eustace, S
    Hentzen, P
    Adams, J
    Harper, K
    Jara, H
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (05) : 1393 - 1395
  • [3] T2-WEIGHTED MR-IMAGING OF THE CHEST - COMPARISON OF ELECTROCARDIOGRAPH-TRIGGERED CONVENTIONAL AND TURBO SPIN-ECHO AND NONTRIGGERED TURBO SPIN-ECHO SEQUENCES
    HADDAD, JL
    ROFSKY, NM
    AMBROSINO, MM
    NAIDICH, DP
    WEINREB, JC
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (03): : 325 - 329
  • [4] MR evaluation of rotator cuff tears: Comparison of turbo spin-echo STIR and fat-suppressed turbo spin-echo T2-weighted images
    Chun, KA
    Ahn, B
    Kim, YJ
    Kim, KT
    [J]. RADIOLOGY, 1999, 213P : 376 - 376
  • [5] Liver MR imaging: Comparison of respiratory triggered fast spin echo with T2-weighted spin-echo and inversion recovery
    Keogan, MT
    Spritzer, CE
    Paulson, EK
    Paine, SS
    Harris, L
    Dahlke, JL
    MacFall, JR
    [J]. ABDOMINAL IMAGING, 1996, 21 (05): : 433 - 439
  • [6] Single-shot turbo spin-echo MR myelography: comparison with 3D-turbo spin-echo MR myelography and T2-turbo spin-echo at 1 T
    Karantanas, AH
    Zibis, AH
    Papanikolaou, N
    [J]. COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2000, 24 (01) : 37 - 42
  • [7] Multi-shot echo-planar Flair imaging of brain tumors: comparison of spin-echo T1-weighted, fast spin-echo T2-weighted, and fast spin-echo Flair imaging
    Tomura, N
    Kato, K
    Takahashi, S
    Sashi, R
    Izumi, J
    Narita, K
    Watarai, J
    [J]. COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2002, 26 (02) : 65 - 72
  • [8] A Spiral Spin-Echo MR Imaging Technique for Improved Flow Artifact Suppression in T1-Weighted Postcontrast Brain Imaging: A Comparison with Cartesian Turbo Spin-Echo
    Li, Z.
    Hu, H. H.
    Miller, J. H.
    Karis, J. P.
    Cornejo, P.
    Wang, D.
    Pipe, J. G.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2016, 37 (04) : 642 - 647
  • [9] MR myelography using inversion recovery turbo spin echo technique: Comparison with heavily T2-weighted turbo spin echo technique
    Eun, CK
    Jeong, HW
    Lee, SJ
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (04) : 123 - 123
  • [10] T2-weighted MR imaging of the liver: Qualitative and quantitative comparison of SPACE MR imaging with turbo spin-echo MR imaging
    Dohan, Anthony
    Gavini, Jean-Philippe
    Place, Vinciane
    Sebbag, Delphine
    Vignaud, Alexandre
    Herbin, Christine
    Hamzi, Lounis
    Boudiaf, Mourad
    Soyer, Philippe
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (11) : E655 - E661