Spin-echo T1-weighted Imaging of the Brain with Interleaved Acquisition and Presaturation Pulse at 3 T: A Feasibility Study Before Clinical Use

被引:3
|
作者
Kasahara, Seiko [1 ]
Miki, Yukio [1 ]
Mori, Nobuyuki [1 ]
Urayama, Shin-ichi [2 ]
Kanagaki, Mitsunori [1 ]
Fushimi, Yasutaka [3 ]
Maeda, Chikara [1 ]
Sawamoto, Nobukatsu [2 ]
Fukuyama, Hidenao [2 ]
Togashi, Kaori [1 ]
机构
[1] Kyoto Univ, Dept Diagnost Imaging & Nucl Med, Sakyo Ku, Kyoto 6068507, Japan
[2] Kyoto Univ, Grad Sch Med, Human Brain Res Ctr, Sakyo Ku, Kyoto 6068507, Japan
[3] Hikone Municipal Hosp, Dept Radiol, Shiga, Japan
关键词
Spin-echo sequence; T1-weighted image; brain; 3; T; ATTENUATED INVERSION-RECOVERY; WHITE MATTER CONTRAST; HIGH FIELD MRI; MAGNETIC-RESONANCE; MACROSCOPIC SUSCEPTIBILITY; ARTIFACTS; STRENGTH; IMAGES; TIME;
D O I
10.1016/j.acra.2008.12.026
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. Although spin-echo (SE) sequence has some advantages over gradient-echo sequence in brain imaging, gradient-echo sequence is commonly used For T1-weighted imaging (T1WI) at 3 T because contrast on SE T1WI is widely believed to be poor at 3 T. Recently, gray-white matter contrast on single-slice and multi-slice SE imaging with interslice gap was reported as better at 3 T than at 1.5 T. This Study examined the feasibility of interleaved SE T1WI of the brain at 3 T. This study also examined whether presaturation pulse (PP) sufficiently suppresses intra-arterial signals because these signals tend to be hyperintense due to longer T1 at 3 T. Materials and Methods. Subjects consisted of 18 healthy volunteers. Two sets of T1WI were performed using SE sequence. One set consisted of imaging without PP, and the other consisted of imaging with PP. Each set contained three types of gapless imaging as follows; sequential, 100% interleaved, and 200% interleaved imaging. In each subject, contrast-to-noise ratio between gray-matter and white-matter (CNRGM-WM) and intra-arterial signals were evaluated. Results. CNRGM-WM was significantly higher on interleaved images than on sequential images, regardless of PP (P < .0001). PP sufficiently suppressed intra-arterial signals (P < .0001). Conclusion. CNRGM-WM On SE T1WI at 3 T can be improved by interleaved acquisition, and PP sufficiently suppressed intra-arterial signals. Interleaved SE T1WI with PP appears clinically feasible at 3 T.
引用
收藏
页码:852 / 857
页数:6
相关论文
共 50 条
  • [11] Comparison of a T1-weighted inversion-recovery-, gradient-echo- and spin-echo sequence for imaging of the brain at 3.0 Testa
    Stehling, C
    Niederstadt, T
    Krämer, S
    Kugel, H
    Schwindt, W
    Heindel, W
    Bachmann, R
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2005, 177 (04): : 536 - 542
  • [12] Dynamic T1-weighted spin-echo MR imaging: The role of digital subtraction in the demonstration of enhancing brain lesions
    Melhem, ER
    Mehta, NR
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1999, 9 (04): : 503 - 508
  • [13] HYPERSIGNAL OF INTERVERTEBRAL DISKS IN T1-WEIGHTED AND SPIN-ECHO MRI SEQUENCES
    VIGNAUX, O
    SARRAZIN, JL
    CORDOLIANI, YS
    COSNARD, G
    JOURNAL DE RADIOLOGIE, 1994, 75 (6-7): : 363 - 367
  • [14] T1-weighted fluid-attenuated inversion recovery and T1-weighted fast spin-echo contrast-enhanced imaging: A comparison in 20 patients with brain lesions
    Al-Saeed, O.
    Ismail, M.
    Athyal, R. P.
    Rudwan, M.
    Khafajee, S.
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2009, 53 (04) : 366 - 372
  • [15] Bone Marrow Metastases: T2-weighted Dixon Spin-Echo Fat Images Can Replace T1-weighted Spin-Echo Images
    Maeder, Yael
    Dunet, Vincent
    Richard, Raphael
    Becce, Fabio
    Omoumi, Patrick
    RADIOLOGY, 2018, 286 (03) : 853 - 864
  • [16] Comparison of contrast-enhanced T1-weighted FLAIR with BLADE, and spin-echo T1-weighted sequences in intracranial MRI
    Alkan, Oezlem
    Kizilkilic, Osman
    Yildirim, Tuelin
    Alibek, Sedat
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2009, 15 (02): : 75 - 80
  • [17] T1-WEIGHTED IMAGES WITH ECG GATING USING PARTIAL FLIP ANGLE SPIN-ECHO IMAGING
    SUGIMURA, K
    KAWAMITSU, H
    YOSHIKAWA, K
    YUASA, K
    KASAI, T
    OKIZUKA, H
    CLINICAL RADIOLOGY, 1994, 49 (12) : 871 - 873
  • [18] Comparison of conventional and turbo spin-echo T1-weighted MR imaging in acute knee trauma
    Eustace, S
    Hentzen, P
    Adams, J
    Harper, K
    Jara, H
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (05) : 1393 - 1395
  • [19] Three-dimensional T1-weighted gradient echo is a suitable alternative to two-dimensional T1-weighted spin echo for imaging the canine brain
    Fleming, Kathryn L.
    Maddox, Thomas W.
    Warren-Smith, Christopher M. R.
    VETERINARY RADIOLOGY & ULTRASOUND, 2019, 60 (05) : 543 - 551
  • [20] MR MYELOGRAPHY USING HEAVILY T2-WEIGHTED FAST SPIN-ECHO PULSE SEQUENCES WITH FAT PRESATURATION
    KRUDY, AG
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 159 (06) : 1315 - 1320