Spin-echo T1-weighted Imaging of the Brain with Interleaved Acquisition and Presaturation Pulse at 3 T: A Feasibility Study Before Clinical Use

被引:3
|
作者
Kasahara, Seiko [1 ]
Miki, Yukio [1 ]
Mori, Nobuyuki [1 ]
Urayama, Shin-ichi [2 ]
Kanagaki, Mitsunori [1 ]
Fushimi, Yasutaka [3 ]
Maeda, Chikara [1 ]
Sawamoto, Nobukatsu [2 ]
Fukuyama, Hidenao [2 ]
Togashi, Kaori [1 ]
机构
[1] Kyoto Univ, Dept Diagnost Imaging & Nucl Med, Sakyo Ku, Kyoto 6068507, Japan
[2] Kyoto Univ, Grad Sch Med, Human Brain Res Ctr, Sakyo Ku, Kyoto 6068507, Japan
[3] Hikone Municipal Hosp, Dept Radiol, Shiga, Japan
关键词
Spin-echo sequence; T1-weighted image; brain; 3; T; ATTENUATED INVERSION-RECOVERY; WHITE MATTER CONTRAST; HIGH FIELD MRI; MAGNETIC-RESONANCE; MACROSCOPIC SUSCEPTIBILITY; ARTIFACTS; STRENGTH; IMAGES; TIME;
D O I
10.1016/j.acra.2008.12.026
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. Although spin-echo (SE) sequence has some advantages over gradient-echo sequence in brain imaging, gradient-echo sequence is commonly used For T1-weighted imaging (T1WI) at 3 T because contrast on SE T1WI is widely believed to be poor at 3 T. Recently, gray-white matter contrast on single-slice and multi-slice SE imaging with interslice gap was reported as better at 3 T than at 1.5 T. This Study examined the feasibility of interleaved SE T1WI of the brain at 3 T. This study also examined whether presaturation pulse (PP) sufficiently suppresses intra-arterial signals because these signals tend to be hyperintense due to longer T1 at 3 T. Materials and Methods. Subjects consisted of 18 healthy volunteers. Two sets of T1WI were performed using SE sequence. One set consisted of imaging without PP, and the other consisted of imaging with PP. Each set contained three types of gapless imaging as follows; sequential, 100% interleaved, and 200% interleaved imaging. In each subject, contrast-to-noise ratio between gray-matter and white-matter (CNRGM-WM) and intra-arterial signals were evaluated. Results. CNRGM-WM was significantly higher on interleaved images than on sequential images, regardless of PP (P < .0001). PP sufficiently suppressed intra-arterial signals (P < .0001). Conclusion. CNRGM-WM On SE T1WI at 3 T can be improved by interleaved acquisition, and PP sufficiently suppressed intra-arterial signals. Interleaved SE T1WI with PP appears clinically feasible at 3 T.
引用
收藏
页码:852 / 857
页数:6
相关论文
共 50 条
  • [41] Comparison of T1-weighted fast spin-echo and T1-weighted fluid-attenuated inversion recovery images of the lumbar spine at 3.0 Tesla
    Lavdas, Eleftherios
    Vlychou, Marianna
    Arikidis, Nikos
    Kapsalaki, Eftychia
    Roka, Violetta
    Fezoulidis, Ioannis V.
    ACTA RADIOLOGICA, 2010, 51 (03) : 290 - 295
  • [42] Feasibility of k-t BLAST For BOLD fMRI With a Spin-Echo Based Acquisition at 3 T and 7 T
    Utting, Jane F.
    Kozerke, Sebastian
    Luechinger, Roger
    Schnitker, Ralph
    Vohn, Rene
    Bhanniny, Rani
    Tilbian, Maral
    Niendorf, Thoralf
    INVESTIGATIVE RADIOLOGY, 2009, 44 (09) : 495 - 502
  • [43] Dynamic fast spin echo T1-weighted MR imaging in pituitary adenomas
    Yoon, PH
    Kim, D
    Kim, H
    RADIOLOGY, 1999, 213P : 310 - 310
  • [44] Feasibility study on the clinical application of CT-based synthetic brain T1-weighted MRI: comparison with conventional T1-weighted MRI
    Li, Zhaotong
    Cao, Gan
    Zhang, Li
    Yuan, Jichun
    Li, Sha
    Zhang, Zeru
    Wu, Fengliang
    Gao, Song
    Xia, Jun
    EUROPEAN RADIOLOGY, 2024, 34 (09) : 5783 - 5799
  • [45] Importance of signal intensity on T1-weighted spin-echo sequence for the diagnosis of chronic cholesteatomatous otitis
    Moustin, Deborah
    Veillon, Francis
    Karch-Georges, Aurelie
    Riehm, Sophie
    Djennaoui, Idir
    Charpiot, Anne
    Venkatasamy, Aina
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2020, 277 (06) : 1601 - 1608
  • [46] Hyperintense benign liver lesions on spin-echo T1-weighted MR images: Pathologic correlations
    Mathieu, D
    Paret, M
    Mahfouz, AE
    CaseiroAlves, F
    Nhieu, JTV
    Anglade, MC
    Rahmouni, A
    Vasile, N
    ABDOMINAL IMAGING, 1997, 22 (04): : 410 - 417
  • [47] Hyperintense benign liver lesions on spin-echo T1-weighted MR images: pathologic correlations
    D. Mathieu
    M. Paret
    A.-E. Mahfouz
    F. Caseiro-Alves
    J. Tran Van Nhieu
    M.-C. Anglade
    A. Rahmouni
    N. Vasile
    Abdominal Imaging, 1997, 22 : 410 - 417
  • [48] 3D fat-suppressed T1-weighted volume isotropic turbo spin-echo acquisition (VISTA) imaging for the evaluation of the ectopic posterior pituitary gland
    Azuma, Minako
    Kadota, Yoshihito
    Matsuyama, Misayo
    Moritake, Hiroshi
    Hirai, Toshinori
    JAPANESE JOURNAL OF RADIOLOGY, 2021, 39 (06) : 564 - 570
  • [49] 3D fat-suppressed T1-weighted volume isotropic turbo spin-echo acquisition (VISTA) imaging for the evaluation of the ectopic posterior pituitary gland
    Minako Azuma
    Yoshihito Kadota
    Misayo Matsuyama
    Hiroshi Moritake
    Toshinori Hirai
    Japanese Journal of Radiology, 2021, 39 : 564 - 570
  • [50] Importance of signal intensity on T1-weighted spin-echo sequence for the diagnosis of chronic cholesteatomatous otitis
    Deborah Moustin
    Francis Veillon
    Aurelie Karch-Georges
    Sophie Riehm
    Idir Djennaoui
    Anne Charpiot
    Aina Venkatasamy
    European Archives of Oto-Rhino-Laryngology, 2020, 277 : 1601 - 1608