Spin-echo T1-weighted Imaging of the Brain with Interleaved Acquisition and Presaturation Pulse at 3 T: A Feasibility Study Before Clinical Use

被引:3
|
作者
Kasahara, Seiko [1 ]
Miki, Yukio [1 ]
Mori, Nobuyuki [1 ]
Urayama, Shin-ichi [2 ]
Kanagaki, Mitsunori [1 ]
Fushimi, Yasutaka [3 ]
Maeda, Chikara [1 ]
Sawamoto, Nobukatsu [2 ]
Fukuyama, Hidenao [2 ]
Togashi, Kaori [1 ]
机构
[1] Kyoto Univ, Dept Diagnost Imaging & Nucl Med, Sakyo Ku, Kyoto 6068507, Japan
[2] Kyoto Univ, Grad Sch Med, Human Brain Res Ctr, Sakyo Ku, Kyoto 6068507, Japan
[3] Hikone Municipal Hosp, Dept Radiol, Shiga, Japan
关键词
Spin-echo sequence; T1-weighted image; brain; 3; T; ATTENUATED INVERSION-RECOVERY; WHITE MATTER CONTRAST; HIGH FIELD MRI; MAGNETIC-RESONANCE; MACROSCOPIC SUSCEPTIBILITY; ARTIFACTS; STRENGTH; IMAGES; TIME;
D O I
10.1016/j.acra.2008.12.026
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. Although spin-echo (SE) sequence has some advantages over gradient-echo sequence in brain imaging, gradient-echo sequence is commonly used For T1-weighted imaging (T1WI) at 3 T because contrast on SE T1WI is widely believed to be poor at 3 T. Recently, gray-white matter contrast on single-slice and multi-slice SE imaging with interslice gap was reported as better at 3 T than at 1.5 T. This Study examined the feasibility of interleaved SE T1WI of the brain at 3 T. This study also examined whether presaturation pulse (PP) sufficiently suppresses intra-arterial signals because these signals tend to be hyperintense due to longer T1 at 3 T. Materials and Methods. Subjects consisted of 18 healthy volunteers. Two sets of T1WI were performed using SE sequence. One set consisted of imaging without PP, and the other consisted of imaging with PP. Each set contained three types of gapless imaging as follows; sequential, 100% interleaved, and 200% interleaved imaging. In each subject, contrast-to-noise ratio between gray-matter and white-matter (CNRGM-WM) and intra-arterial signals were evaluated. Results. CNRGM-WM was significantly higher on interleaved images than on sequential images, regardless of PP (P < .0001). PP sufficiently suppressed intra-arterial signals (P < .0001). Conclusion. CNRGM-WM On SE T1WI at 3 T can be improved by interleaved acquisition, and PP sufficiently suppressed intra-arterial signals. Interleaved SE T1WI with PP appears clinically feasible at 3 T.
引用
收藏
页码:852 / 857
页数:6
相关论文
共 50 条
  • [31] Hypointense lesions on T1-weighted spin-echo magnetic resonance imaging -: Relation to clinical characteristics in subgroups of patients with multiple sclerosis
    van Walderveen, MAA
    Lycklama à Nijeholt, GJ
    Adèr, HJ
    Jongen, PJH
    Polman, CH
    Castelijns, JA
    Barkhof, F
    ARCHIVES OF NEUROLOGY, 2001, 58 (01) : 76 - 81
  • [32] IMPROVED CONTRAST OF ENHANCING BRAIN-LESIONS ON POSTGADOLINIUM, T1-WEIGHTED SPIN-ECHO IMAGES WITH USE OF MAGNETIZATION-TRANSFER
    FINELLI, DA
    HURST, GC
    GULLAPALI, RP
    BELLON, EM
    RADIOLOGY, 1994, 190 (02) : 553 - 559
  • [33] Detection of Brain Metastases by 3-Dimensional Magnetic Resonance Imaging at 3 T: Comparison Between T1-Weighted Volume Isotropic Turbo Spin Echo Acquisition and 3-Dimensional T1-Weighted Fluid-Attenuated Inversion Recovery Imaging
    Yoshida, Atsushi
    Tha, Khin Khin
    Fujima, Noriyuki
    Zaitsu, Yuri
    Yoshida, Daisuke
    Tsukahara, Akiko
    Onodera, Shunsuke
    Shirato, Hiroki
    Terae, Satoshi
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2013, 37 (01) : 84 - 90
  • [34] Histopathologic correlate of hypointense lesions on T1-weighted spin-echo MRI in multiple sclerosis
    van Walderveen, MAA
    Kamphorst, W
    Scheltens, P
    van Waesberghe, JHTM
    Ravid, R
    Valk, J
    Polman, CH
    Barkhof, F
    NEUROLOGY, 1998, 50 (05) : 1282 - 1288
  • [35] T1-weighted MR imaging of glioma at 3T: a comparative study of 3D MPRAGE vs. conventional 2D spin-echo imaging
    Dodo, Toshiki
    Okada, Tomohisa
    Yamamoto, Akira
    Kanagaki, Mitsunori
    Fushimi, Yasutaka
    Okada, Tsutomu
    Sakata, Akihiko
    Arakawa, Yoshiki
    Miyamoto, Susumu
    Togashi, Kaori
    CLINICAL IMAGING, 2016, 40 (06) : 1257 - 1261
  • [36] Evaluation of the Subscapularis Tendon Tears on 3T Magnetic Resonance Arthrography: Comparison of Diagnostic Performance of T1-Weighted Spectral Presaturation with Inversion-Recovery and T2-Weighted Turbo Spin-Echo Sequences
    Lee, Hoseok
    Ahn, Joong Mo
    Kang, Yusuhn
    Oh, Joo Han
    Lee, Eugene
    Lee, Joon Woo
    Kang, Heung Sik
    KOREAN JOURNAL OF RADIOLOGY, 2018, 19 (02) : 320 - 327
  • [37] T1-Weighted Magnetic Resonance Carotid Plaque Imaging: a Comparison between Conventional and Fast Spin-Echo Techniques
    Narumi, Shinsuke
    Sasaki, Makoto
    Miyazawa, Haruna
    Natori, Tatsunori
    Ito, Kohei
    Ogasawara, Kuniaki
    Kobayashi, Masakazu
    Hitomi, Jiro
    Terayama, Yasuo
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2017, 26 (02): : 273 - 279
  • [38] Comparison of spin echo T1-weighted sequences versus fast spin-echo proton density-weighted sequences for evaluation of meniscal tears at 1.5 T
    Andrew B. Wolff
    Lorenzo L. Pesce
    Jim S. Wu
    L. Ryan Smart
    Michael J. Medvecky
    Andrew H. Haims
    Skeletal Radiology, 2009, 38 : 21 - 29
  • [39] Comparison of spin echo T1-weighted sequences versus fast spin-echo proton density-weighted sequences for evaluation of meniscal tears at 1.5 T
    Wolff, Andrew B.
    Pesce, Lorenzo L.
    Wu, Jim S.
    Smart, L. Ryan
    Medvecky, Michael J.
    Haims, Andrew H.
    SKELETAL RADIOLOGY, 2009, 38 (01) : 21 - 29
  • [40] Small hepatocellular carcinoma: assessment with T1-weighted spin-echo magnetic resonance imaging with and without fat suppression
    Koushima, Y
    Ebara, M
    Fukuda, H
    Morimoto, N
    Sugiura, N
    Yoshikawa, M
    Sanada, M
    Saisho, H
    Matsumoto, T
    Yukawa, M
    EUROPEAN JOURNAL OF RADIOLOGY, 2002, 41 (01) : 34 - 41