Magnetic resonance imaging (MRI) is one of the most powerful imaging modality in clinics and is essential for the diagnosis of strokes through carotid artery imaging. The limiting factor for high-quality MRI is the signal-to-noise ratio (SNR) performance of the radio frequency (RF) coils. The current RF surface coils, however, are made of rigid or semiflexible materials with very limited bending properties. As a result, their SNR is limited because they cannot be placed very close to the imaging area, thus receiving noises from parts of the human body, which are not intended to be imaged. Taking advantage of the computerized embroidery and laser cutting technology, in this paper, we utilize electrotextile to design, fabricate, and measure multilayer RF coil array system for 3 Tesla (3T) MRI to improve the SNR performance. The proposed RF coil array system provides an ergonomic and high-performance solution to the 3T MRI systems. A roadmap to systematically design electrotextile RF coil arrays is proposed. RF coil array is characterized to have the accurate resonant frequency, good impedance matching, and low mutual coupling. In addition, magnetic field distribution, bending effects, and human body effects are also discussed. A systematic method to characterize the performance of the electrotextile pattern is studied and used to assist the development and performance characterization. Finally, the high resolution and high SNR images of various kinds of phantoms are obtained using the University of California at Los Angeles (UCLA) Antenna Lab electrotextile coil array after its integration with the 3T MRI scanners at UCLA David Geffen School of Medicine Translational Research Imaging Center. Compared with the conventional surface coil, more than 10 dB SNR increase is observed at the depth of 0.5 cm and 3 dB increase at the depth of 3 cm.
引用
收藏
页码:5115 / 5125
页数:11
相关论文
共 50 条
  • [1] Flexible RF Coil Array System Utilizing Electro-textiles for 3T MRI Carotid Artery Imaging
    Zhang, Daisong
    Rahmat-Samii, Yahya
    2017 IEEE INTERNATIONAL SYMPOSIUM ON ANTENNAS AND PROPAGATION & USNC/URSI NATIONAL RADIO SCIENCE MEETING, 2017, : 1015 - 1016
  • [2] An 8-channel RF coil array for carotid artery MR imaging in humans at 3 T
    Hu, Xiaoqing
    Zhang, Lei
    Zhang, Xiaoliang
    Zhu, Huabin
    Chen, Xiao
    Zhang, Yongqin
    Chung, Yiu-Cho
    Liu, Xin
    Zheng, Hairong
    Li, Ye
    MEDICAL PHYSICS, 2016, 43 (04) : 1897 - 1906
  • [3] Numerical Design of Dual Resonant Phased Array RF Coil for MRI 3T and 7T System
    Basari
    Yuliyanti, Sri
    Rahardjo, Eko Tjipto
    Zulkifli, Fitri Yuli
    2015 2ND INTERNATIONAL CONFERENCE ON INFORMATION TECHNOLOGY, COMPUTER, AND ELECTRICAL ENGINEERING (ICITACEE), 2015, : 275 - 278
  • [4] Ultra-flexible 3T HIC Receive Array for Carotid Imaging
    Zhang, Bei
    Cloos, Martijn A.
    Yang, Joseph
    Nguyen, Thanh D.
    Brown, Ryan
    PROCEEDINGS OF THE 2019 INTERNATIONAL CONFERENCE ON ELECTROMAGNETICS IN ADVANCED APPLICATIONS (ICEAA), 2019, : 459 - 464
  • [5] Automatic tuned MRI RF coil for multinuclear imaging of small animals at 3T
    Muftuler, LT
    Gulsen, G
    Sezen, KD
    Nalcioglu, O
    JOURNAL OF MAGNETIC RESONANCE, 2002, 155 (01) : 39 - 44
  • [6] 10-channel phased-array coil for carotid wall MRI at 3T
    de Buck, Matthijs H. S.
    Jezzard, Peter
    Frost, Robert
    Randell, Chris
    Hurst, Katherine
    Choudhury, Robin P.
    Robson, Matthew D.
    Biasiolli, Luca
    PLOS ONE, 2023, 18 (08):
  • [7] Continuous ASL (CASL) perfusion MRI with an array coil and parallel imaging at 3T
    Wang, Z
    Wang, JJ
    Connick, TJ
    Wetmore, GS
    Detre, JA
    MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (03) : 732 - 737
  • [8] Advanced Design of Birdcage RF Coil for Various Absorption Regions at 3T MRI System
    Lee, Jung-Woo
    Choe, Bo-Young
    Yoon, Sung-Ik
    Choi, Chi-Bong
    Huh, Soon-Nyoung
    JOURNAL OF THE KOREAN MAGNETIC RESONANCE SOCIETY, 2005, 9 (01): : 48 - 60
  • [9] Design of Hexagonal RF Surface coil for 3T MRI Scanner by Characteristic Mode Analysis
    Ullah, Rafi
    Venkatesan, Soundarya
    2022 IEEE MICROWAVES, ANTENNAS, AND PROPAGATION CONFERENCE, MAPCON, 2022, : 1100 - 1103
  • [10] Numerical Design of RF Birdcage Coil without Lumped Elements for MRI 3T System
    Basari
    Priatna, Arwan
    Rahardjo, Eko Tjipto
    Zulkifli, Fitri Yuli
    2015 INTERNATIONAL CONFERENCE QUALITY IN RESEARCH (QIR), 2015, : 90 - 93