A Novel Flexible Electrotextile 3T MRI RF Coil Array for Carotid Artery Imaging: Design, Characterization, and Prototyping

被引:19
|
作者
Zhang, Daisong [1 ]
Rahmat-Samu, Yahya [1 ]
机构
[1] Univ Calif Los Angeles, Dept Elect Engn, Los Angeles, CA 90095 USA
关键词
Coil; embroidered; e-textile; flexible antenna; magnetic resonance imaging (MRI); radio frequency (RF); signal-to-noise ratio (SNR); SURFACE-ROUGHNESS; TEXTILES;
D O I
10.1109/TAP.2019.2891700
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Magnetic resonance imaging (MRI) is one of the most powerful imaging modality in clinics and is essential for the diagnosis of strokes through carotid artery imaging. The limiting factor for high-quality MRI is the signal-to-noise ratio (SNR) performance of the radio frequency (RF) coils. The current RF surface coils, however, are made of rigid or semiflexible materials with very limited bending properties. As a result, their SNR is limited because they cannot be placed very close to the imaging area, thus receiving noises from parts of the human body, which are not intended to be imaged. Taking advantage of the computerized embroidery and laser cutting technology, in this paper, we utilize electrotextile to design, fabricate, and measure multilayer RF coil array system for 3 Tesla (3T) MRI to improve the SNR performance. The proposed RF coil array system provides an ergonomic and high-performance solution to the 3T MRI systems. A roadmap to systematically design electrotextile RF coil arrays is proposed. RF coil array is characterized to have the accurate resonant frequency, good impedance matching, and low mutual coupling. In addition, magnetic field distribution, bending effects, and human body effects are also discussed. A systematic method to characterize the performance of the electrotextile pattern is studied and used to assist the development and performance characterization. Finally, the high resolution and high SNR images of various kinds of phantoms are obtained using the University of California at Los Angeles (UCLA) Antenna Lab electrotextile coil array after its integration with the 3T MRI scanners at UCLA David Geffen School of Medicine Translational Research Imaging Center. Compared with the conventional surface coil, more than 10 dB SNR increase is observed at the depth of 0.5 cm and 3 dB increase at the depth of 3 cm.
引用
收藏
页码:5115 / 5125
页数:11
相关论文
共 50 条
  • [21] Imaging adult zebrafish brain structures using micro-fabricated RF coil on 3T MRI system
    Hsieh, Meng-Chi
    Kuo, Li-Wei
    Wu, Edzer
    Chen, Jyh-Horng
    2007 JOINT MEETING OF THE 6TH INTERNATIONAL SYMPOSIUM ON NONINVASIVE FUNCTIONAL SOURCE IMAGING OF THE BRAIN AND HEART AND THE INTERNATIONAL CONFERENCE ON FUNCTIONAL BIOMEDICAL IMAGING, 2007, : 177 - 179
  • [22] Cortical Microinfarcts on 3T MRI in Patients With Carotid Artery Stenosis.
    Takasugi, Junji
    Miwa, Kaori
    Watanabe, Yoshiyuki
    Okazaki, Shuhei
    Todo, Kenichi
    Sasaki, Tsutomu
    Mochizuki, Hideki
    STROKE, 2019, 50
  • [23] MRI compatibility study of an integrated PET/RF-coil prototype system at 3T
    Akram, Md Shahadat Hossain
    Obata, Takayuki
    Suga, Mikio
    Nishikido, Fumihiko
    Yoshida, Eiji
    Saito, Kazuyuki
    Yamaya, Taiga
    JOURNAL OF MAGNETIC RESONANCE, 2017, 283 : 62 - 70
  • [24] Prostate MRI using an external phased array wearable pelvic coil at 3T: comparison with an endorectal coil
    O'Donohoe, Rory L.
    Dunne, Ruth M.
    Kimbrell, Vera
    Tempany, Clare M.
    ABDOMINAL RADIOLOGY, 2019, 44 (03) : 1062 - 1069
  • [25] Prostate MRI using an external phased array wearable pelvic coil at 3T: comparison with an endorectal coil
    Rory L. O’Donohoe
    Ruth M. Dunne
    Vera Kimbrell
    Clare M. Tempany
    Abdominal Radiology, 2019, 44 : 1062 - 1069
  • [26] Design and Characterization of a Metasurface Enhancement Plate for 3T MRI
    Stoja, Endri
    Konstandin, Simon
    Wilke, Robin Niklas
    Philipp, Dennis
    Umathum, Reiner
    Jenne, Juergen
    Betancourt, Diego
    Bertuch, Thomas
    Guenther, Matthias
    2020 IEEE MTT-S INTERNATIONAL MICROWAVE BIOMEDICAL CONFERENCE (IMBIOC), 2020,
  • [27] Preliminary Results of 7-Channel Insertional pTx Array Coil for 3T MRI
    Ryu, Yeun Chul
    JOURNAL OF MAGNETICS, 2017, 22 (02) : 238 - 243
  • [28] Impact of RF Shimming on RF-Induced Heating Near Implantable Medical Electrodes in a 3T MRI Coil
    Zeng, Qi
    Wang, Qingyan
    Kainz, Wolfgang
    Chen, Ji
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2020, 62 (01) : 52 - 64
  • [29] Integration of Electro-textile RF Coil Array with Magnetic Resonance Imaging (MRI) System: Design Strategies and Characterization Methods
    Zhang, Daisong
    Rahmat-Samii, Yahya
    2018 IEEE INTERNATIONAL WORKSHOP ON ANTENNA TECHNOLOGY (IWAT), 2018,
  • [30] Conformal Occipital 18-Channel Receive-Only RF Coil for 3T MRI
    Mathieu, William
    Popovic, Milica
    Farivar, Reza