A Novel Flexible Electrotextile 3T MRI RF Coil Array for Carotid Artery Imaging: Design, Characterization, and Prototyping

被引:19
|
作者
Zhang, Daisong [1 ]
Rahmat-Samu, Yahya [1 ]
机构
[1] Univ Calif Los Angeles, Dept Elect Engn, Los Angeles, CA 90095 USA
关键词
Coil; embroidered; e-textile; flexible antenna; magnetic resonance imaging (MRI); radio frequency (RF); signal-to-noise ratio (SNR); SURFACE-ROUGHNESS; TEXTILES;
D O I
10.1109/TAP.2019.2891700
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Magnetic resonance imaging (MRI) is one of the most powerful imaging modality in clinics and is essential for the diagnosis of strokes through carotid artery imaging. The limiting factor for high-quality MRI is the signal-to-noise ratio (SNR) performance of the radio frequency (RF) coils. The current RF surface coils, however, are made of rigid or semiflexible materials with very limited bending properties. As a result, their SNR is limited because they cannot be placed very close to the imaging area, thus receiving noises from parts of the human body, which are not intended to be imaged. Taking advantage of the computerized embroidery and laser cutting technology, in this paper, we utilize electrotextile to design, fabricate, and measure multilayer RF coil array system for 3 Tesla (3T) MRI to improve the SNR performance. The proposed RF coil array system provides an ergonomic and high-performance solution to the 3T MRI systems. A roadmap to systematically design electrotextile RF coil arrays is proposed. RF coil array is characterized to have the accurate resonant frequency, good impedance matching, and low mutual coupling. In addition, magnetic field distribution, bending effects, and human body effects are also discussed. A systematic method to characterize the performance of the electrotextile pattern is studied and used to assist the development and performance characterization. Finally, the high resolution and high SNR images of various kinds of phantoms are obtained using the University of California at Los Angeles (UCLA) Antenna Lab electrotextile coil array after its integration with the 3T MRI scanners at UCLA David Geffen School of Medicine Translational Research Imaging Center. Compared with the conventional surface coil, more than 10 dB SNR increase is observed at the depth of 0.5 cm and 3 dB increase at the depth of 3 cm.
引用
收藏
页码:5115 / 5125
页数:11
相关论文
共 50 条
  • [31] Impacts of RF Shimming on MRI Induced Heating of Implantable Medical Lead in 3T Birdcage Coil
    Zeng, Qi
    Wang, Qingyan
    Zheng, Jianfeng
    Kainz, Wolfgang
    Chen, Ji
    2017 IEEE MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM (IMS), 2017, : 1235 - 1237
  • [32] Measurement and characterization of RF nonuniformity over the heart at 3T using body coil transmission
    Sung, Kyunghyun
    Nayak, Krishna S.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (03) : 643 - 648
  • [33] Flexible, 31-Channel Breast Coil for Enhanced Parallel Imaging Performance at 3T
    Hancu, Ileana
    Fiveland, Eric
    Park, Keith
    Giaquinto, Randy O.
    Rohling, Kenneth
    Wiesinger, Florian
    MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (02) : 897 - 905
  • [34] Local excitation black blood imaging at 3T: Application to the carotid artery wall
    Bornstedt, Axel
    Bernhardt, Peter
    Hombach, Vinzenz
    Kamenz, Joachim
    Spiess, Jochen
    Subgang, Anne
    Rasche, Volker
    MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (05) : 1207 - 1211
  • [35] Increased Vessel Depiction of the Carotid Bifurcation with a Specialized 16-Channel Phased Array Coil at 3T
    Tate, Quinn
    Kim, Seong-Eun
    Treiman, Gerald
    Parker, Dennis L.
    Hadley, J. Rock
    MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (05) : 1486 - 1493
  • [36] Dynamic contrast enhanced imaging of mice kidney metabolism using high-temperature superconducting RF coil on a 3T MRI system
    Chen, Kai-Yuan
    Kuo, Li-Wei
    Lin, Wei-Ting
    Su, Chia-Hao
    Chen, Jyh-Horng
    2007 JOINT MEETING OF THE 6TH INTERNATIONAL SYMPOSIUM ON NONINVASIVE FUNCTIONAL SOURCE IMAGING OF THE BRAIN AND HEART AND THE INTERNATIONAL CONFERENCE ON FUNCTIONAL BIOMEDICAL IMAGING, 2007, : 180 - 182
  • [37] The first clinical test of Add-on PET: A PET-integrated RF coil for 3T MRI
    Takahashi, Miwako
    Nishikido, Fumihiko
    Akamatsu, Go
    Tashima, Hideaki
    Suga, Mikio
    Iwao, Yuma
    Yamaya, Taiga
    JOURNAL OF NUCLEAR MEDICINE, 2024, 65
  • [38] Safety and imaging performance of two-channel RF shimming for fetal MRI at 3T
    Yetisir, Filiz
    Abaci Turk, Esra
    Guerin, Bastien
    Gagoski, Borjan A.
    Grant, P. Ellen
    Adalsteinsson, Elfar
    Wald, Lawrence L.
    MAGNETIC RESONANCE IN MEDICINE, 2021, 86 (05) : 2810 - 2821
  • [39] Cortical Cerebral Microinfarcts on 3T Magnetic Resonance Imaging in Patients With Carotid Artery Stenosis
    Takasugi, Junji
    Miwa, Kaori
    Watanabe, Yoshiyuki
    Okazaki, Shuhei
    Todo, Kenichi
    Sasaki, Tsutomu
    Sakaguchi, Manabu
    Mochizuki, Hideki
    STROKE, 2019, 50 (03) : 639 - 644
  • [40] A novel RF resonator using microstrip transmission line for human body MRI at 3T
    Son, Hyeok-Woo
    Cho, Young-Ki
    Yoo, Hyungsuk
    2013 PROCEEDINGS OF THE INTERNATIONAL SYMPOSIUM ON ANTENNAS AND PROPAGATION (ISAP), VOLS 1 AND 2, 2013,