Revision arthroplasty of the hip - Modularity of neck and metaphyseal components

被引:0
|
作者
Koester, G. [1 ]
Walde, T. A. [2 ]
机构
[1] Orthopad Chirurg & Traumatol Chirurg Orthopad Fac, D-64653 Lorsch, Germany
[2] Univ Klin Gottingen, Abt Unfallchirurg Plast & Wiederherstellungschiru, Gottingen, Germany
来源
ORTHOPADE | 2009年 / 38卷 / 03期
关键词
Hip; Revision arthroplasty; Cementless fixation; Modular stem design; Interchangeable neck; FEMORAL COMPONENT; FOLLOW-UP; STEM; REPLACEMENT; PROSTHESIS; FIXATION; EXPERIENCE; CEMENT;
D O I
10.1007/s00132-008-1346-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Modular parts in femoral components used for hip arthroplasty are reported to be predilection sites for mechanical failure. The possible benefit of their use is therefore controversial. We report the outcome of 97 revision hip arthroplasties using a non-cemented femoral component with a modular metaphyseal part and an interchangeable neck (ProfemurA (R)). The femoral defects treated included Paprosky types I-III. The average follow-up was 5 years (range 3-10 years). No mechanical failure of the modular parts and taper connections has been observed so far. The percentage of patients with a balanced leg length increased from 32% preoperative to 65% postoperative. The mean leg length discrepancy could be reduced from 1.4 cm preoperative to 0.5 cm postoperative. A total of 5 re-revisions were required, including 2 cases of infection. The cumulative survival of the implants due to aseptic loosening was 96.5%. Because of the achieved results the use of the modular stem investigated in this study can be classified as safe and effective for revision hip arthroplasty. The interchangeable neck proved to be a useful completion of the revision system.
引用
收藏
页码:238 / +
页数:7
相关论文
共 50 条
  • [21] Outcome of a modular head–neck adapter system in revision hip arthroplasty
    Maik Hoberg
    Christian Konrads
    Simon Huber
    Stephan Reppenhagen
    Matthias Walcher
    André Steinert
    Thomas Barthel
    Maximilian Rudert
    Archives of Orthopaedic and Trauma Surgery, 2015, 135 : 1469 - 1474
  • [22] Fracture of a titanium femoral neck after revision total hip arthroplasty
    Zimmerer, Alexander
    Ogunleye, Philips
    Navas, Luis
    Hauschild, Matthias
    BMJ CASE REPORTS, 2022, 15 (05)
  • [23] Effect of femoral neck modularity upon the prosthetic range of motion in total hip arthroplasty
    Glen A. Turley
    Damian R. Griffin
    Mark A. Williams
    Medical & Biological Engineering & Computing, 2014, 52 : 685 - 694
  • [24] Effect of femoral neck modularity upon the prosthetic range of motion in total hip arthroplasty
    Turley, Glen A.
    Griffin, Damian R.
    Williams, Mark A.
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2014, 52 (08) : 685 - 694
  • [25] Revision total knee arthroplasty with modular components inserted with metaphyseal cement and stems without cement
    Peters, CL
    Erickson, J
    Kloepper, RG
    Mohr, RA
    JOURNAL OF ARTHROPLASTY, 2005, 20 (03): : 302 - 308
  • [26] What is the Survivorship of Fully Coated Femoral Components in Revision Hip Arthroplasty?
    Lachiewicz, Paul F.
    Soileau, Elizabeth S.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2015, 473 (02) : 549 - 554
  • [27] Use of custom triflanged acetabular components in revision total hip arthroplasty
    Holt, GE
    Dennis, DA
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (429) : 209 - 214
  • [28] REVISION HIP-ARTHROPLASTY USING UNCEMENTED COMPONENTS - EARLY EXPERIENCE
    HEYNEN, G
    HORNE, JG
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1988, 70 (03): : 507 - 507
  • [29] Revision of Cemented Total Hip Arthroplasty with Cementless Components in Three Dogs
    Torres, Bryan T.
    Budsberg, Steven C.
    VETERINARY SURGERY, 2009, 38 (01) : 81 - 86
  • [30] Cemented revision of failed uncemented femoral components of total hip arthroplasty
    Davis, CM
    Berry, DJ
    Harmsen, WS
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (07): : 1264 - 1269