Effect of femoral neck modularity upon the prosthetic range of motion in total hip arthroplasty

被引:13
|
作者
Turley, Glen A. [1 ]
Griffin, Damian R. [2 ]
Williams, Mark A. [1 ]
机构
[1] Univ Warwick, WMG, Coventry CV4 7AL, W Midlands, England
[2] Univ Warwick, Warwick Med Sch, Coventry CV2 2DX, W Midlands, England
基金
英国工程与自然科学研究理事会;
关键词
Total hip arthroplasty; Femoral neck modularity; Impingement; Range of motion; IMPINGEMENT; DISLOCATION; CUP; ORIENTATION; COMPONENTS; FAILURE; DESIGN;
D O I
10.1007/s11517-014-1171-9
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
In total hip arthroplasty, aseptic loosening and dislocation are associated with not being able to achieve the correct prosthetic component orientation. Femoral neck modularity has been proposed as a solution to this problem by allowing the surgeon to alter either the neck-shaft or version angle of the prosthetic femoral component intra-operatively. A single replicate full factorial design was used to evaluate how effective a modular femoral neck cementless stem was in restoring a healthy prosthetic range of motion in comparison with a leading fixed-neck cementless stem with the standard modular parameters. It was found that, if altered to a large enough degree, femoral neck modularity can increase the amount of prosthetic motion as well as alter its position to where it is required physiologically. However, there is a functional limit to the amount that can be corrected and there is a risk with regard to the surgeon having to select the optimum modular neck before any benefit is realised.
引用
收藏
页码:685 / 694
页数:10
相关论文
共 50 条
  • [1] Effect of femoral neck modularity upon the prosthetic range of motion in total hip arthroplasty
    Glen A. Turley
    Damian R. Griffin
    Mark A. Williams
    [J]. Medical & Biological Engineering & Computing, 2014, 52 : 685 - 694
  • [2] Modularity of the Femoral Component in Total Hip Arthroplasty
    Srinivasan, Anand
    Jung, Edward
    Levine, Brett Russell
    [J]. JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2012, 20 (04) : 214 - 222
  • [3] Influence of femoral bowing on range of motion after total hip arthroplasty
    Akiyama, Keisuke
    Shibuya, Takaaki
    [J]. INTERNATIONAL ORTHOPAEDICS, 2018, 42 (08) : 1795 - 1802
  • [4] Influence of femoral bowing on range of motion after total hip arthroplasty
    Keisuke Akiyama
    Takaaki Shibuya
    [J]. International Orthopaedics, 2018, 42 : 1795 - 1802
  • [5] Limited range of motion of hip resurfacing arthroplasty due to unfavorable ratio of prosthetic head size and femoral neck diameter
    Kluess, Daniel
    Zietz, Carmen
    Lindner, Tobias
    Mittelmeier, Wolfram
    Schmitz, Klaus-Peter
    Bader, Rainer
    [J]. ACTA ORTHOPAEDICA, 2008, 79 (06) : 748 - 754
  • [6] Head-neck modularity for total hip arthroplasty - Is it necessary?
    Hozack, WJ
    Mesa, JJ
    Rothman, RF
    [J]. JOURNAL OF ARTHROPLASTY, 1996, 11 (04): : 397 - 399
  • [7] Outcomes of neck modularity in total hip arthroplasty: an Italian perspective
    Papalia R.
    Di Martino A.
    Caldaria A.
    Zampogna B.
    Denaro V.
    [J]. MUSCULOSKELETAL SURGERY, 2019, 103 (3) : 215 - 220
  • [8] The Effect of Obesity on Hemiarthroplasty and Total Hip Arthroplasty for Femoral Neck Fractures
    Degenova, Daniel T.
    Passias, Braden J.
    Paulini, Alex S.
    Myers, Philip M.
    Dues, Boston
    Taylor, Benjamin C.
    [J]. Journal of Long-Term Effects of Medical Implants, 2024, 34 (02) : 53 - 60
  • [9] EFFECT OF FEMORAL OFFSET ON RANGE OF MOTION AND ABDUCTOR MUSCLE STRENGTH AFTER TOTAL HIP-ARTHROPLASTY
    MCGRORY, BJ
    MORREY, BF
    CAHALAN, TD
    AN, KN
    CABANELA, ME
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1995, 77B (06): : 865 - 869
  • [10] The effect of cup medialization and lateralization on hip range of motion in total hip arthroplasty
    Shoji, Takeshi
    Yamasaki, Takuma
    Izumi, Soutarou
    Kenji, Mifuji
    Sawa, Mikiya
    Yasunaga, Yuji
    Adachi, Nobuo
    [J]. CLINICAL BIOMECHANICS, 2018, 57 : 121 - 128