Anthracite combustion characteristics and NOx formation of a 300 MWe down-fired boiler with swirl burners at different loads after the implementation of a new combustion system

被引:52
|
作者
Chen, Zhichao [1 ]
Wang, Qingxiang [1 ]
Wang, Bingnan [1 ]
Zeng, Lingyan [1 ]
Che, Miaomiao [1 ]
Zhang, Xin [1 ]
Li, Zhengqi [1 ]
机构
[1] Harbin Inst Technol, Sch Energy Sci & Engn, 92,West Dazhi St, Harbin 150001, Peoples R China
基金
中国国家自然科学基金;
关键词
Down-fired boiler; Swirl burner; Overfire air; Load; Pulverized coal combustion; NOx emissions; UTILITY BOILER; MULTIPLE-INJECTION; SECONDARY-AIR; SUPERCRITICAL BOILER; STAGING TECHNOLOGY; COAL; EMISSIONS; FURNACE; RATIO; REDUCTION;
D O I
10.1016/j.apenergy.2016.12.063
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A new combustion system has been applied to a 300 MWe down-fired boiler with swirl burners to reduce NOx emissions. The unit provided the introduction of overfire air (OFA) and a decrease in the flow area of the inner and outer secondary air ducts of the swirl burners. Industrial experiments on the retrofitted boiler were performed at different loads. Full-scale measurements of the flue gas temperature distribution in the burner outlet region, the furnace temperature distributions measured by a pyrometer and the local mean gas species concentrations in the region near the sidewall were made at loads of 180, 250, and 300 MWe. The results show that the ignition distance increased with decreasing load, especially as the load decreased from 250 MWe to 180 MWe. At three different loads, the retrofitted coal/air flow could be all ignited in time at a distance in the range of 0.6-1.4 m from the burner outlet. Compared with the original combustion system, the ignition distance of the coal/air flow was significantly reduced at a load of 300 MWe. In addition, at a load of 300 MW, the temperature of the boiler hopper was much higher than that at loads of 180 MWe and 250 MW, Compared with the original combustion system, the upper furnace temperature decreased slowly with increasing measurement height at a load of 300 MWe after the retrofit. Measurements of the 02 and CO concentrations in the region near the sidewall indicate that the fullness degree of the coal flame in the furnace at different loads was different. After the retrofit, the reheat steam temperatures reached the design temperature of 541 degrees C at loads of 180 MWe and 250 MWe, and the average reheat steam temperatures increased by approximately 13 degrees C. Compared with the original combustion system, a significant NOx reduction (more than 40%) at different loads was achieved without increasing the levels of unburnt carbon in the fly ash. (C) 2016 Published by Elsevier Ltd.
引用
收藏
页码:133 / 141
页数:9
相关论文
共 50 条
  • [1] Industrial-scale investigations of anthracite combustion characteristics and NOx emissions in a retrofitted 300 MWe down-fired utility boiler with swirl burners
    Chen, Zhichao
    Wang, Qingxiang
    Zhang, Xiaoyan
    Zeng, Lingyan
    Zhang, Xin
    He, Tao
    Liu, Tao
    Li, Zhengqi
    [J]. APPLIED ENERGY, 2017, 202 : 169 - 177
  • [2] Influence of Staged-Air on Combustion Characteristics and NOx Emissions of a 300 MWe Down-Fired Boiler with Swirl Burners
    Li, Zhengqi
    Fan, Subo
    Liu, Guangkui
    Yang, Xuehai
    Chen, Zhichao
    Su, Wei
    Wang, Lin
    [J]. ENERGY & FUELS, 2010, 24 (01) : 38 - 45
  • [3] Asymmetric combustion characteristics and NOx emissions of a down-fired 300 MWe utility boiler at different boiler loads
    Kuang, Min
    Li, Zhengqi
    Zhang, Yan
    Chen, Xiachao
    Jia, Jinzhao
    Zhu, Qunyi
    [J]. ENERGY, 2012, 37 (01) : 580 - 590
  • [4] Asymmetric combustion characteristics and NOx emissions of a down-fired 300MWe utility boiler at different boiler loads
    School of Energy Science and Engineering, Harbin Institute of Technology, 92 West Dazhi Street, Harbin 150001, China
    [J]. Energy, 1600, 1 (580-590):
  • [5] Combustion and NOx emission characteristics of a retrofitted down-fired 660 MWe utility boiler at different loads
    Li, Zhengqi
    Liu, Guangkui
    Zhu, Qunyi
    Chen, Zhichao
    Ren, Feng
    [J]. APPLIED ENERGY, 2011, 88 (07) : 2400 - 2406
  • [6] Promotion of Anthracite Burnout for a 300 MWe Down-Fired Boiler with a Novel Combustion Technology
    Wang, Qingxiang
    Chen, Zhichao
    Yan, Tianshu
    Liu, Tao
    Zeng, Lingyan
    Li, Zhengqi
    [J]. ENERGY & FUELS, 2018, 32 (11) : 11924 - 11935
  • [7] Improved NOx Emissions and Combustion Characteristics for a Retrofitted Down-fired 300-MWe Utility Boiler
    Li, Zhengqi
    Ren, Feng
    Chen, Zhichao
    Liu, Guangkui
    Xu, Zhenxing
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2010, 44 (10) : 3926 - 3931
  • [8] Experimental characterization of anthracite combustion and NOx emission for a 300-MWe down-fired boiler with a novel combustion system: Influence of primary and vent air distributions
    Wang, Qingxiang
    Chen, Zhichao
    Han, Hui
    Zeng, Lingyan
    Li, Zhengqi
    [J]. APPLIED ENERGY, 2019, 238 : 1551 - 1562
  • [9] Influence of the Overfire Air Ratio on the NOx Emission and Combustion Characteristics of a down-Fired 300-MWe Utility Boiler
    Ren, Feng
    Li, Zhengqi
    Chen, Zhichao
    Fan, Subo
    Liu, Guangkui
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2010, 44 (16) : 6510 - 6516
  • [10] Numerical Simulation of Flow and Combustion Characteristics in a 300 MWe Down-Fired Boiler with Different Overfire Air Angles
    Ren, Feng
    Li, Zhengqi
    Liu, Guangkui
    Chen, Zhichao
    Zhu, Qunyi
    [J]. ENERGY & FUELS, 2011, 25 (04) : 1457 - 1464