Asymmetric combustion characteristics and NOx emissions of a down-fired 300 MWe utility boiler at different boiler loads

被引:59
|
作者
Kuang, Min [1 ]
Li, Zhengqi [1 ]
Zhang, Yan [1 ]
Chen, Xiachao [1 ]
Jia, Jinzhao [1 ]
Zhu, Qunyi [1 ]
机构
[1] Harbin Inst Technol, Sch Energy Sci & Engn, Harbin 150001, Peoples R China
关键词
Down-fired boiler; Asymmetric combustion; NOx emission; Boiler load; FLOW SPLIT BURNERS; OPERATING-CONDITIONS; STAGED-AIR; FURNACE; TEMPERATURE; SCALE; FIELD;
D O I
10.1016/j.energy.2011.10.046
中图分类号
O414.1 [热力学];
学科分类号
摘要
To investigate the aerodynamic field, cold airflow experiments were conducted under different boiler loads in a cold small-scale model of a down-fired pulverized-coal 300 MWe utility boiler. At 300 MWe and 250 MWe loads, a deflected flow field appeared in the lower furnace. In contrast, at a 150 MWe load, a U-shaped flow field appeared in regions near the left- and right-side walls in the lower furnace. Concurrently, the regions near the two wing walls adjacent to the front arch had received deflected upward airflow emanating from the region near the rear wall. Moreover, a symmetric W-shaped flow field appeared in the central regions below the front and rear arches. Industrial-sized experiments on the full-scale furnace were also performed at different loads with measurements taken of gas temperatures in the burner region and near the right-side wall, as well as heat fluxes and gas components in the near-wall region. Asymmetric combustion appeared at 300 MWe and 250 MWe loads, with large differences arising in gas temperatures, gas components, and heat fluxes between zones near the front and rear walls. At 150 MWe load, gas temperatures, gas components and heat fluxes are, in general, symmetrically distributed throughout the furnace. By decreasing the load, differences in gas temperatures, gas components, and heat fluxes near the front and rear walls decrease, as did NOx emissions. Meanwhile, the carbon content in fly ash essentially decreased, yielding an increase in boiler efficiency assisted by a drop in exhaust gas temperature. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:580 / 590
页数:11
相关论文
共 50 条
  • [1] Asymmetric combustion characteristics and NOx emissions of a down-fired 300MWe utility boiler at different boiler loads
    School of Energy Science and Engineering, Harbin Institute of Technology, 92 West Dazhi Street, Harbin 150001, China
    [J]. Energy, 1600, 1 (580-590):
  • [2] Improved NOx Emissions and Combustion Characteristics for a Retrofitted Down-fired 300-MWe Utility Boiler
    Li, Zhengqi
    Ren, Feng
    Chen, Zhichao
    Liu, Guangkui
    Xu, Zhenxing
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2010, 44 (10) : 3926 - 3931
  • [3] Combustion and NOx emission characteristics of a retrofitted down-fired 660 MWe utility boiler at different loads
    Li, Zhengqi
    Liu, Guangkui
    Zhu, Qunyi
    Chen, Zhichao
    Ren, Feng
    [J]. APPLIED ENERGY, 2011, 88 (07) : 2400 - 2406
  • [4] Influence of the Overfire Air Ratio on the NOx Emission and Combustion Characteristics of a down-Fired 300-MWe Utility Boiler
    Ren, Feng
    Li, Zhengqi
    Chen, Zhichao
    Fan, Subo
    Liu, Guangkui
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2010, 44 (16) : 6510 - 6516
  • [5] Influence of Staged-Air on Combustion Characteristics and NOx Emissions of a 300 MWe Down-Fired Boiler with Swirl Burners
    Li, Zhengqi
    Fan, Subo
    Liu, Guangkui
    Yang, Xuehai
    Chen, Zhichao
    Su, Wei
    Wang, Lin
    [J]. ENERGY & FUELS, 2010, 24 (01) : 38 - 45
  • [6] Improving Combustion Characteristics and NOx Emissions of a Down-Fired 350 MWe Utility Boiler with Multiple Injection and Multiple Staging
    Kuang, Min
    Li, Zhengqi
    Xu, Shantian
    Zhu, Qunyi
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2011, 45 (08) : 3803 - 3811
  • [7] Industrial-scale investigations of anthracite combustion characteristics and NOx emissions in a retrofitted 300 MWe down-fired utility boiler with swirl burners
    Chen, Zhichao
    Wang, Qingxiang
    Zhang, Xiaoyan
    Zeng, Lingyan
    Zhang, Xin
    He, Tao
    Liu, Tao
    Li, Zhengqi
    [J]. APPLIED ENERGY, 2017, 202 : 169 - 177
  • [8] Anthracite combustion characteristics and NOx formation of a 300 MWe down-fired boiler with swirl burners at different loads after the implementation of a new combustion system
    Chen, Zhichao
    Wang, Qingxiang
    Wang, Bingnan
    Zeng, Lingyan
    Che, Miaomiao
    Zhang, Xin
    Li, Zhengqi
    [J]. APPLIED ENERGY, 2017, 189 : 133 - 141
  • [9] Influence of declivitous secondary air on combustion characteristics of a down-fired 300-MWe utility boiler
    Li, Zhengqi
    Ren, Feng
    Chen, Zhichao
    Chen, Zhao
    Wang, Jingjie
    [J]. FUEL, 2010, 89 (02) : 410 - 416
  • [10] Influence of Inner Secondary Air Vane Angle on Combustion Characteristics and NOx Emissions of a Down-Fired Pulverized-Coal 300 MWe Utility Boiler
    Fan, Subo
    Li, Zhengqi
    Zhu, Qunyi
    [J]. COMBUSTION SCIENCE AND TECHNOLOGY, 2013, 185 (06) : 975 - 989