Influence of the Overfire Air Ratio on the NOx Emission and Combustion Characteristics of a down-Fired 300-MWe Utility Boiler

被引:42
|
作者
Ren, Feng [1 ]
Li, Zhengqi [1 ]
Chen, Zhichao [1 ]
Fan, Subo [1 ]
Liu, Guangkui [1 ]
机构
[1] Harbin Inst Technol, Sch Energy Sci & Engn, Harbin 150001, Peoples R China
关键词
COAL COMBUSTION; SECONDARY AIR; FLOW; REDUCTION;
D O I
10.1021/es100956d
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Down-fired boilers used to burn low-volatile coals have high NO emissions To find a way of solving this problem, an overfire air (OFA) system was introduced on a 300 MW, down-fired boiler. Full-scale experiments were performed on this retrofitted boiler to explore the influence of the OFA ratio (the mass flux ratio of OFA to the total combustion air) on the combustion and NO, emission characteristics in the furnace Measurements were taken of gas temperature distributions along the primary air and coal mixture flows, average gas temperatures along the furnace height, concentrations of gases such as O-2, CO, and NOx in the near-wall region and carbon content in the fly ash. Data were compared for five different OFA ratios The results show that as the OFA ratio increases from 12% to 35%, the NO emission decreases from 1308 to 966 mg/Nm(3) (at 6% O-2 dry) and the carbon content in the fly ash increases from 6.53% to 15 86% Considering both the environmental and economic effect, 25% was chosen as the optimized OFA ratio
引用
收藏
页码:6510 / 6516
页数:7
相关论文
共 50 条
  • [1] Influence of declivitous secondary air on combustion characteristics of a down-fired 300-MWe utility boiler
    Li, Zhengqi
    Ren, Feng
    Chen, Zhichao
    Chen, Zhao
    Wang, Jingjie
    [J]. FUEL, 2010, 89 (02) : 410 - 416
  • [2] Improved NOx Emissions and Combustion Characteristics for a Retrofitted Down-fired 300-MWe Utility Boiler
    Li, Zhengqi
    Ren, Feng
    Chen, Zhichao
    Liu, Guangkui
    Xu, Zhenxing
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2010, 44 (10) : 3926 - 3931
  • [3] Influence of Separated Overfire Air Ratio and Location on Combustion and NOx Emission Characteristics for a 600 MWe Down-Fired Utility Boiler with a Novel Combustion System
    Ma, Lun
    Fang, Qingyan
    Lv, Dangzhen
    Zhang, Cheng
    Chen, Gang
    Chen, Yiping
    Duan, Xuenong
    [J]. ENERGY & FUELS, 2015, 29 (11) : 7630 - 7640
  • [4] Effect of different inner secondary-air vane angles on combustion characteristics of primary combustion zone for a down-fired 300-MWe utility boiler with overfire air
    Wang, Qingxiang
    Chen, Zhichao
    Che, Miaomiao
    Zeng, Lingyan
    Li, Zhengqi
    Song, Minhang
    [J]. APPLIED ENERGY, 2016, 182 : 29 - 38
  • [5] Influence of the secondary air-box damper opening on airflow and combustion characteristics of a down-fired 300-MWe utility boiler
    Ren, Feng
    Li, Zhengqi
    Zhang, Yubin
    Sun, Shaozeng
    Zhang, Xiaohui
    Chen, Zhichao
    [J]. ENERGY & FUELS, 2007, 21 (02) : 668 - 676
  • [6] Experimental characterization of anthracite combustion and NOx emission for a 300-MWe down-fired boiler with a novel combustion system: Influence of primary and vent air distributions
    Wang, Qingxiang
    Chen, Zhichao
    Han, Hui
    Zeng, Lingyan
    Li, Zhengqi
    [J]. APPLIED ENERGY, 2019, 238 : 1551 - 1562
  • [7] Numerical Simulation of Flow and Combustion Characteristics in a 300 MWe Down-Fired Boiler with Different Overfire Air Angles
    Ren, Feng
    Li, Zhengqi
    Liu, Guangkui
    Chen, Zhichao
    Zhu, Qunyi
    [J]. ENERGY & FUELS, 2011, 25 (04) : 1457 - 1464
  • [8] Asymmetric combustion characteristics and NOx emissions of a down-fired 300 MWe utility boiler at different boiler loads
    Kuang, Min
    Li, Zhengqi
    Zhang, Yan
    Chen, Xiachao
    Jia, Jinzhao
    Zhu, Qunyi
    [J]. ENERGY, 2012, 37 (01) : 580 - 590
  • [9] Asymmetric combustion characteristics and NOx emissions of a down-fired 300MWe utility boiler at different boiler loads
    School of Energy Science and Engineering, Harbin Institute of Technology, 92 West Dazhi Street, Harbin 150001, China
    [J]. Energy, 1600, 1 (580-590):
  • [10] Combustion and NOx emission characteristics of a retrofitted down-fired 660 MWe utility boiler at different loads
    Li, Zhengqi
    Liu, Guangkui
    Zhu, Qunyi
    Chen, Zhichao
    Ren, Feng
    [J]. APPLIED ENERGY, 2011, 88 (07) : 2400 - 2406