Anthracite combustion characteristics and NOx formation of a 300 MWe down-fired boiler with swirl burners at different loads after the implementation of a new combustion system

被引:52
|
作者
Chen, Zhichao [1 ]
Wang, Qingxiang [1 ]
Wang, Bingnan [1 ]
Zeng, Lingyan [1 ]
Che, Miaomiao [1 ]
Zhang, Xin [1 ]
Li, Zhengqi [1 ]
机构
[1] Harbin Inst Technol, Sch Energy Sci & Engn, 92,West Dazhi St, Harbin 150001, Peoples R China
基金
中国国家自然科学基金;
关键词
Down-fired boiler; Swirl burner; Overfire air; Load; Pulverized coal combustion; NOx emissions; UTILITY BOILER; MULTIPLE-INJECTION; SECONDARY-AIR; SUPERCRITICAL BOILER; STAGING TECHNOLOGY; COAL; EMISSIONS; FURNACE; RATIO; REDUCTION;
D O I
10.1016/j.apenergy.2016.12.063
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A new combustion system has been applied to a 300 MWe down-fired boiler with swirl burners to reduce NOx emissions. The unit provided the introduction of overfire air (OFA) and a decrease in the flow area of the inner and outer secondary air ducts of the swirl burners. Industrial experiments on the retrofitted boiler were performed at different loads. Full-scale measurements of the flue gas temperature distribution in the burner outlet region, the furnace temperature distributions measured by a pyrometer and the local mean gas species concentrations in the region near the sidewall were made at loads of 180, 250, and 300 MWe. The results show that the ignition distance increased with decreasing load, especially as the load decreased from 250 MWe to 180 MWe. At three different loads, the retrofitted coal/air flow could be all ignited in time at a distance in the range of 0.6-1.4 m from the burner outlet. Compared with the original combustion system, the ignition distance of the coal/air flow was significantly reduced at a load of 300 MWe. In addition, at a load of 300 MW, the temperature of the boiler hopper was much higher than that at loads of 180 MWe and 250 MW, Compared with the original combustion system, the upper furnace temperature decreased slowly with increasing measurement height at a load of 300 MWe after the retrofit. Measurements of the 02 and CO concentrations in the region near the sidewall indicate that the fullness degree of the coal flame in the furnace at different loads was different. After the retrofit, the reheat steam temperatures reached the design temperature of 541 degrees C at loads of 180 MWe and 250 MWe, and the average reheat steam temperatures increased by approximately 13 degrees C. Compared with the original combustion system, a significant NOx reduction (more than 40%) at different loads was achieved without increasing the levels of unburnt carbon in the fly ash. (C) 2016 Published by Elsevier Ltd.
引用
收藏
页码:133 / 141
页数:9
相关论文
共 50 条
  • [21] Improving Combustion Characteristics and NOx Emissions of a Down-Fired 350 MWe Utility Boiler with Multiple Injection and Multiple Staging
    Kuang, Min
    Li, Zhengqi
    Xu, Shantian
    Zhu, Qunyi
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2011, 45 (08) : 3803 - 3811
  • [22] An innovative combustion technology for a down-fired boiler with swirl burners: Gas/solid flow characteristics with various burner injection angles
    Wang, Qingxiang
    Chen, Zhichao
    Zeng, Lingyan
    Li, Zhengqi
    [J]. JOURNAL OF CLEANER PRODUCTION, 2019, 228 : 1296 - 1310
  • [23] Influence of Inner Secondary Air Vane Angle on Combustion Characteristics and NOx Emissions of a Down-Fired Pulverized-Coal 300 MWe Utility Boiler
    Fan, Subo
    Li, Zhengqi
    Zhu, Qunyi
    [J]. COMBUSTION SCIENCE AND TECHNOLOGY, 2013, 185 (06) : 975 - 989
  • [24] Combustion optimization and NOx reduction of a 600 MWe down-fired boiler by rearrangement of swirl burner and introduction of separated over-fire air
    Yang, Wu
    Wang, Ben
    Lei, Siyuan
    Wang, Ke
    Chen, Tao
    Song, Zijian
    Ma, Chuan
    Zhou, Yiding
    Sun, Lushi
    [J]. JOURNAL OF CLEANER PRODUCTION, 2019, 210 : 1120 - 1130
  • [25] Influence of the adjustable vane position on the flow and combustion characteristics of a down-fired pulverized-coal 300 MWe utility boiler
    Ren, Feng
    Li, Zhengqi
    Jing, Jianping
    Zhang, Xiaohui
    Chen, Zhichao
    Zhang, Juwei
    [J]. FUEL PROCESSING TECHNOLOGY, 2008, 89 (12) : 1297 - 1305
  • [26] Effect of the separated overfire air location on the combustion optimization and NOx reduction of a 600 MWe FW down-fired utility boiler with a novel combustion system
    Ma, Lun
    Fang, Qingyan
    Tan, Peng
    Zhang, Cheng
    Chen, Gang
    Lv, Dangzhen
    Duan, Xuenong
    Chen, Yiping
    [J]. APPLIED ENERGY, 2016, 180 : 104 - 115
  • [27] Influence of vent air valve opening on combustion characteristics of a down-fired pulverized-coal 300 MWe utility boiler
    Li, Zhengqi
    Ren, Feng
    Zhang, Jie
    Zhang, Xiaohui
    Chen, Zhichao
    Chen, Lizhe
    [J]. FUEL, 2007, 86 (15) : 2457 - 2462
  • [28] Reducing NOx Emissions for a 600 MWe Down-Fired Pulverized-Coal Utility Boiler by Applying a Novel Combustion System
    Ma, Lun
    Fang, Qingyan
    Lv, Dangzhen
    Zhang, Cheng
    Chen, Yiping
    Chen, Gang
    Duan, Xuenong
    Wang, Xihuan
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2015, 49 (21) : 13040 - 13049
  • [29] Influence of Angled Secondary Air on Combustion Characteristics of a 660-MWe Down-Fired Utility Boiler
    Li, Zhengqi
    Ren, Feng
    Liu, Guangkui
    Shen, Shanping
    Chen, Zhichao
    [J]. COMBUSTION SCIENCE AND TECHNOLOGY, 2011, 183 (03) : 238 - 251
  • [30] Influence of outer secondary-air vane angle on combustion characteristics and NOx emissions of a down-fired pulverized-coal 300 MWe utility boiler
    Fan, Subo
    Li, Zhengqi
    Yang, Xuehai
    Liu, Guangkui
    Chen, Zhichao
    [J]. FUEL, 2010, 89 (07) : 1525 - 1533