Anthracite combustion characteristics and NOx formation of a 300 MWe down-fired boiler with swirl burners at different loads after the implementation of a new combustion system

被引:52
|
作者
Chen, Zhichao [1 ]
Wang, Qingxiang [1 ]
Wang, Bingnan [1 ]
Zeng, Lingyan [1 ]
Che, Miaomiao [1 ]
Zhang, Xin [1 ]
Li, Zhengqi [1 ]
机构
[1] Harbin Inst Technol, Sch Energy Sci & Engn, 92,West Dazhi St, Harbin 150001, Peoples R China
基金
中国国家自然科学基金;
关键词
Down-fired boiler; Swirl burner; Overfire air; Load; Pulverized coal combustion; NOx emissions; UTILITY BOILER; MULTIPLE-INJECTION; SECONDARY-AIR; SUPERCRITICAL BOILER; STAGING TECHNOLOGY; COAL; EMISSIONS; FURNACE; RATIO; REDUCTION;
D O I
10.1016/j.apenergy.2016.12.063
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A new combustion system has been applied to a 300 MWe down-fired boiler with swirl burners to reduce NOx emissions. The unit provided the introduction of overfire air (OFA) and a decrease in the flow area of the inner and outer secondary air ducts of the swirl burners. Industrial experiments on the retrofitted boiler were performed at different loads. Full-scale measurements of the flue gas temperature distribution in the burner outlet region, the furnace temperature distributions measured by a pyrometer and the local mean gas species concentrations in the region near the sidewall were made at loads of 180, 250, and 300 MWe. The results show that the ignition distance increased with decreasing load, especially as the load decreased from 250 MWe to 180 MWe. At three different loads, the retrofitted coal/air flow could be all ignited in time at a distance in the range of 0.6-1.4 m from the burner outlet. Compared with the original combustion system, the ignition distance of the coal/air flow was significantly reduced at a load of 300 MWe. In addition, at a load of 300 MW, the temperature of the boiler hopper was much higher than that at loads of 180 MWe and 250 MW, Compared with the original combustion system, the upper furnace temperature decreased slowly with increasing measurement height at a load of 300 MWe after the retrofit. Measurements of the 02 and CO concentrations in the region near the sidewall indicate that the fullness degree of the coal flame in the furnace at different loads was different. After the retrofit, the reheat steam temperatures reached the design temperature of 541 degrees C at loads of 180 MWe and 250 MWe, and the average reheat steam temperatures increased by approximately 13 degrees C. Compared with the original combustion system, a significant NOx reduction (more than 40%) at different loads was achieved without increasing the levels of unburnt carbon in the fly ash. (C) 2016 Published by Elsevier Ltd.
引用
收藏
页码:133 / 141
页数:9
相关论文
共 50 条
  • [41] Combustion stability, burnout and NOx emissions of the 300-MW down-fired boiler with bituminous coal: Load variation and low-load comparison with anthracite
    Zhang, Xin
    Chen, Zhichao
    Zhang, Mingdi
    Zeng, Lingyan
    Li, Zhengqi
    [J]. FUEL, 2021, 295
  • [42] Effect of separated over-fire air angle on combustion and NOx emissions in a down-fired utility boiler with a novel combustion system
    Ma, Lun
    Yu, Shenghui
    Fang, Qingyan
    Zhang, Cheng
    Chen, Gang
    [J]. PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2020, 138 : 57 - 66
  • [43] Gas/Particle Flow Characteristics, Combustion and NOx Emissions of Down-Fired 600 MWe Supercritical Utility Boilers with Respect to Two Configurations of Combustion Systems
    Kuang, Min
    Li, Zhengqi
    Zhu, Qunyi
    Chen, Lizhe
    Zhang, Yan
    Lai, Jinping
    [J]. ENERGY & FUELS, 2012, 26 (06) : 3316 - 3328
  • [44] Combustion stability and NOX emission characteristics of a 300 MWe tangentially fired boiler under ultra-low loads with deep-air staging
    Ma, Dafu
    Zhang, Shouyu
    He, Xiang
    Zhang, Jian
    Ding, Xian
    [J]. ENERGY, 2023, 269
  • [45] Influence of the Parallel C-Layer Secondary Air on Flow, Combustion and Nox Generation Characteristics of a 600mwe FW Down-Fired Boiler Retrofitted with a Stable Combustion Organization Mode
    Du, He
    Li, Zhengqi
    Liu, Zheng
    Zhang, Mingdi
    Chen, Zhichao
    Song, Jian
    Fang, Fan
    Xiao, Ronghua
    [J]. COMBUSTION SCIENCE AND TECHNOLOGY, 2024, 196 (10) : 1529 - 1553
  • [46] Impact of the Overfire Air Location on Combustion Improvement and NOx Abatement of a Down-Fired 350 MWe Utility Boiler with Multiple Injection and Multiple Staging
    Kuang, Min
    Li, Zhengqi
    Xu, Shantian
    Zhu, Xingying
    Zhang, Yan
    Zhu, Qunyi
    [J]. ENERGY & FUELS, 2011, 25 (10) : 4322 - 4332
  • [47] Airflow and Combustion Characteristics and NOx Formation of the Low-Volatile Coal-Fired Utility Boiler at Different Loads
    Li, Song
    Chen, Zhichao
    Jiang, Bingkun
    Liu, Guangkui
    Li, Zhengqi
    Zhang, Xiqian
    Zhu, Qunyi
    [J]. CLEAN COAL TECHNOLOGY AND SUSTAINABLE DEVELOPMENT, 2016, : 489 - 496
  • [48] Airflow and Combustion Characteristics and NOx Formation of the Low-Volatile Coal-Fired Utility Boiler at Different Loads
    Li, Song
    Chen, Zhichao
    Jiang, Bingkun
    Liu, Guangkui
    Li, Zhengqi
    Zhang, Xiqian
    Zhu, Qunyi
    [J]. CLEAN COAL TECHNOLOGY AND SUSTAINABLE DEVELOPMENT, 2016, : 197 - 205
  • [49] Numerical investigation on combustion and NOx emissions of a down-fired 350 MWe utility boiler with multiple injection and multiple staging: Effect of the air stoichiometric ratio in the primary combustion zone
    Kuang, Min
    Zhu, Qunyi
    Li, Zhengqi
    Zhang, Xiang
    [J]. FUEL PROCESSING TECHNOLOGY, 2013, 109 : 32 - 42
  • [50] Effect of central secondary air on flow and combustion characteristics of 600-MWe down-fired boiler: From laboratory to industrial site
    Zhang, Xin
    Chen, Zhichao
    Jiang, Guangfei
    Zeng, Lingyan
    Li, Zhengqi
    [J]. FUEL, 2022, 330