Cardiac troponin T in patients with cardiac implantable electronic devices undergoing magnetic resonance imaging

被引:7
|
作者
Higgins, John V. [1 ]
Watson, Robert E., Jr. [4 ]
Jaffe, Allan S. [3 ]
Dalzell, Connie [2 ]
Acker, Nancy [2 ]
Felmlee, Joel P. [4 ]
Asirvatham, Samuel J. [2 ]
Cha, Yong-Mei [2 ]
Friedman, Paul A. [2 ]
Kapa, Suraj [2 ,5 ]
机构
[1] Univ Nebraska Med Ctr, Cardiovasc Dis, Omaha, NE USA
[2] Mayo Clin, Heart Rhythm Serv, Rochester, MN 55905 USA
[3] Mayo Clin, Cardiovasc Dis, Rochester, MN 55905 USA
[4] Mayo Clin, Radiol, Rochester, MN 55905 USA
[5] Mayo Clin, Div Cardiovasc Dis, 200 First St SW, Rochester, MN 55905 USA
关键词
Magnetic resonance imaging; Cardiac pacemaker; Implantable cardioverter-defibrillator; Cardiac troponin; CARDIOVERTER-DEFIBRILLATORS; IN-VIVO; PERMANENT PACEMAKERS; 1.5; TESLA; SAFETY; LEADS; MRI; VITRO; ASSAY;
D O I
10.1007/s10840-015-0064-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Magnetic resonance imaging (MRI) has been safely performed in many patients with cardiac implantable electronic devices (CIEDs) using institution-specific protocols. A potential risk of MRI is myocardial heating and cardiac injury, which might be detectable with cardiac Troponin (cTn). We evaluated this in patients with CIEDs undergoing MRI. Prospective data were collected from 2008 to the present in patients with CIEDs undergoing clinically indicated MRI performed under institutional protocol. Cardiac Troponin T (cTnT) levels were drawn both before and 24-36 h after the procedure. The collective data were retrospectively analyzed. MRI exams (n = 512) were performed in 398 patients. Of these, there were 348 unique scans with cTnT recorded before and after MRI (median age 68, IQ 56-78; 62 % men). cTnT did not significantly change for the group as a whole (0.00 +/- 0.056). There were 22 (6.3 %) exams with cTnT change a parts per thousand yen0.002 ng/mL following MRI (range 0.01-0.09 ng/mL). There were no clinically significant events in these patients directly attributable to MR. There were no significant changes in pacing threshold or impedance in the group with elevated cardiac biomarkers. There are very few situations where myocardial injury as detected by cTnT in patients undergoing MRI with CIEDs could be detected. No adverse clinical events or functional changes of the device were noted, even in those with increases in cTnT. Our experience supports that MRI can be performed safely for appropriately selected patients under close clinical observation. Proactive monitoring with the present iteration of cardiac biomarkers appears to be of limited utility, but prospective monitoring with high sensitivity assays may be able to detect subclinical myocardial damage.
引用
收藏
页码:91 / 97
页数:7
相关论文
共 50 条
  • [41] Magnetic resonance Imaging of Implantable cardiac rhythm devices at 3.0 tesla
    Gimbel, J. Rod
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2008, 31 (07): : 795 - 801
  • [42] Magnetic resonance imaging in patients with cardiac implanted electronic devices: focus on contraindications to magnetic resonance imaging protocols
    Horwood, Laura
    Attili, Anil
    Luba, Frank
    Ibrahim, El-Sayed H.
    Parmar, Hemant
    Stojanovska, Jadranka
    Gadoth-Goodman, Sharon
    Fette, Carey
    Oral, Hakan
    Bogun, Frank
    EUROPACE, 2017, 19 (05): : 812 - 817
  • [43] Consensus document on magnetic resonance imaging in patients with cardiac implanted electronic devices
    Almeida, Ana G.
    Antonio, Natalia
    Saraiva, Carla
    Ferreira, Antonio Miguel
    Reis, Antonio Hipolito
    Marques, Hugo
    Ferreira, Nuno Dias
    Oliveira, Mario
    REVISTA PORTUGUESA DE CARDIOLOGIA, 2021, 40 (01) : 41 - 52
  • [44] LACK OF MYOCARDIAL INJURY AFTER MAGNETIC RESONANCE IMAGING IN PATIENTS WITH CONDITIONAL AND NON-CONDITIONAL CARDIAC IMPLANTABLE ELECTRONIC DEVICES -A HIGH SENSITIVITY TROPONIN EVALUATION
    Lobo, Ronstan
    Edmonson, Heidi A.
    Donato, Leslie
    Friedman, Paul
    Wockenfus, Amy M.
    Cha, Yong-Mei
    McGee, Kiaran P.
    Felmlee, Joel P.
    Watson, Robert
    Jaffe, Allan
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 77 (18) : 300 - 300
  • [45] Cardiovascular magnetic resonance imaging in patients with cardiac implantable electronic devices: best practice and real-world experience
    Seewoester, Timm
    Loebe, Susanne
    Hilbert, Sebastian
    Bollmann, Andreas
    Sommer, Philipp
    Lindemann, Frank
    Bacevicius, Justinas
    Schoene, Katharina
    Richter, Sergio
    Doering, Michael
    Paetsch, Ingo
    Hindricks, Gerhard
    Jahnke, Cosima
    EUROPACE, 2019, 21 (08): : 1220 - 1228
  • [46] Cardiac Implantable Electronic Device Safety during Magnetic Resonance Imaging
    Hwang, You Mi
    Kim, Jun
    Lee, Ji Hyun
    Kim, Minsu
    Nam, Gi-Byoung
    Choi, Kee-Joon
    Kim, You-Ho
    KOREAN CIRCULATION JOURNAL, 2016, 46 (06) : 804 - 810
  • [47] Provision of magnetic resonance imaging for patients with 'MR-conditional' cardiac implantable electronic devices: an unmet clinical need
    Sabzevari, Kian
    Oldman, James
    Herrey, Anna S.
    Moon, James C.
    Kydd, Anna C.
    Manisty, Charlotte
    EUROPACE, 2017, 19 (03): : 425 - 431
  • [48] Magnetic Resonance Imaging for Patients with Cardiac Implantable Electronic Devices: Reduced Concerns Regarding Safety, but Scrutiny Remains Critical
    Jung, Jung Im
    KOREAN CIRCULATION JOURNAL, 2016, 46 (06) : 765 - 767
  • [49] Multicenter retrospective evaluation of magnetic resonance imaging in pediatric and congenital heart disease patients with cardiac implantable electronic devices
    Gakenheimer-Smith, Lindsey
    Ou, Zhining
    Kuang, Jinqiu
    Moore, Jeremy P.
    Burrows, Austin
    Kovach, Joshua
    Dechert, Brynn
    Beach, Cheyenne M.
    Ayers, Mark
    Tan, Reina Bianca
    Mostafavifar, Mina
    Mah, Douglas Y.
    Conner, Tracy Marrs
    Turpin, Susan
    Avasarala, Kishor
    Shah, Maully J.
    Webster, Gregory
    Posey, Jessica
    Etheridge, Susan P.
    Binka, Edem
    Niu, Mary
    Asaki, S. Yukiko
    Lambert, Linda M.
    Pilcher, Thomas A.
    HEART RHYTHM, 2023, 20 (12) : 1752 - 1758
  • [50] STRESS VASODILATOR EFFECTS ON PATIENTS WITH CARDIAC IMPLANTABLE ELECTRONIC DEVICES AND SAFETY IN THE MAGNETIC RESONANCE ENVIRONMENT
    Miller, Lauren
    Airapetov, Sergei
    Pillai, Ajay
    Kalahasty, Gautham
    Trankle, Cory
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2022, 79 (09) : 1295 - 1295