Cardiac troponin T in patients with cardiac implantable electronic devices undergoing magnetic resonance imaging

被引:7
|
作者
Higgins, John V. [1 ]
Watson, Robert E., Jr. [4 ]
Jaffe, Allan S. [3 ]
Dalzell, Connie [2 ]
Acker, Nancy [2 ]
Felmlee, Joel P. [4 ]
Asirvatham, Samuel J. [2 ]
Cha, Yong-Mei [2 ]
Friedman, Paul A. [2 ]
Kapa, Suraj [2 ,5 ]
机构
[1] Univ Nebraska Med Ctr, Cardiovasc Dis, Omaha, NE USA
[2] Mayo Clin, Heart Rhythm Serv, Rochester, MN 55905 USA
[3] Mayo Clin, Cardiovasc Dis, Rochester, MN 55905 USA
[4] Mayo Clin, Radiol, Rochester, MN 55905 USA
[5] Mayo Clin, Div Cardiovasc Dis, 200 First St SW, Rochester, MN 55905 USA
关键词
Magnetic resonance imaging; Cardiac pacemaker; Implantable cardioverter-defibrillator; Cardiac troponin; CARDIOVERTER-DEFIBRILLATORS; IN-VIVO; PERMANENT PACEMAKERS; 1.5; TESLA; SAFETY; LEADS; MRI; VITRO; ASSAY;
D O I
10.1007/s10840-015-0064-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Magnetic resonance imaging (MRI) has been safely performed in many patients with cardiac implantable electronic devices (CIEDs) using institution-specific protocols. A potential risk of MRI is myocardial heating and cardiac injury, which might be detectable with cardiac Troponin (cTn). We evaluated this in patients with CIEDs undergoing MRI. Prospective data were collected from 2008 to the present in patients with CIEDs undergoing clinically indicated MRI performed under institutional protocol. Cardiac Troponin T (cTnT) levels were drawn both before and 24-36 h after the procedure. The collective data were retrospectively analyzed. MRI exams (n = 512) were performed in 398 patients. Of these, there were 348 unique scans with cTnT recorded before and after MRI (median age 68, IQ 56-78; 62 % men). cTnT did not significantly change for the group as a whole (0.00 +/- 0.056). There were 22 (6.3 %) exams with cTnT change a parts per thousand yen0.002 ng/mL following MRI (range 0.01-0.09 ng/mL). There were no clinically significant events in these patients directly attributable to MR. There were no significant changes in pacing threshold or impedance in the group with elevated cardiac biomarkers. There are very few situations where myocardial injury as detected by cTnT in patients undergoing MRI with CIEDs could be detected. No adverse clinical events or functional changes of the device were noted, even in those with increases in cTnT. Our experience supports that MRI can be performed safely for appropriately selected patients under close clinical observation. Proactive monitoring with the present iteration of cardiac biomarkers appears to be of limited utility, but prospective monitoring with high sensitivity assays may be able to detect subclinical myocardial damage.
引用
收藏
页码:91 / 97
页数:7
相关论文
共 50 条
  • [31] 3 Tesla magnetic resonance imaging in patients with cardiac electronic implantable devices: a single center experience
    Nikorowitsch, J.
    Tahir, E.
    Erley, J.
    Muellerleile, K.
    Metzner, A.
    Adam, G.
    Blankenberg, S.
    Kirchhof, P.
    Toennis, T.
    Fluschnik, N.
    EUROPEAN HEART JOURNAL, 2022, 43 : 482 - 482
  • [32] "Power-on resets" in cardiac implantable electronic devices during magnetic resonance imaging
    Higgins, John V.
    Sheldon, Seth H.
    Watson, Robert E., Jr.
    Dalzell, Connie
    Acker, Nancy
    Cha, Yong-Mei
    Asirvatham, Samuel J.
    Kapa, Suraj
    Felmlee, Joel P.
    Friedman, Paul A.
    HEART RHYTHM, 2015, 12 (03) : 540 - 544
  • [33] Clinical Performance of Magnetic Resonance Imaging Conditional and Nonconditional Cardiac Implantable Electronic Devices
    Shah, Anand D.
    Patel, Adarsh U.
    Knezevic, Andrea
    Hoskins, Michael H.
    Hirsh, David S.
    Merchant, Faisal M.
    El Chami, Mikhael F.
    Delurgio, David B.
    Patel, Anshul M.
    Leon, Angel R.
    Langberg, Jonathan J.
    Lloyd, Michael S.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2017, 40 (05): : 467 - 475
  • [34] MANAGEMENT OF PATIENTS WITH CARDIAC IMPLANTABLE ELECTRONIC DEVICES UNDERGOING MAGNETIC RESONANCE IMAGING - PROPOSAL FOR UNIFIED HOSPITAL PROTOCOL: CROATIAN WORKING GROUP ON ARRHYTHMIAS AND CARDIAC PACING
    Pavlovic, Nikola
    Dula, Kristijan
    Kuharic, Ivan
    Brusich, Sandro
    Velagic, Vedran
    Jurisic, Zrinka
    Bakotic, Zoran
    Anic, Ante
    Nikolic, Borka Pezo
    Radeljic, Vjekoslav
    Cubranic, Zlatko
    Zeljkovic, Ivan
    Zadravec, Dijana
    Manola, Sime
    ACTA CLINICA CROATICA, 2020, 59 (01) : 119 - 125
  • [35] Safety of magnetic resonance imaging in patients with cardiac implantable electronic devices with generator and lead(s) brand mismatch
    Minaskeian, Nareg
    Hajnal, Sofia P.
    Liu, Michael B.
    Klooster, Lindsay M.
    Devick, Katrina L.
    Schwartz, Linda
    Jokerst, Clinton E.
    Sorajja, Dan
    Scott, Luis R. P.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (03):
  • [36] Magnetic Resonance Imaging in People With Cardiac Implantable Electronic Devices: A Population Based Cohort Study
    Gillam, Marianne H.
    Inacio, Maria C. S.
    Pratt, Nicole L.
    Shakib, Sepehr
    Roughead, Elizabeth E.
    HEART LUNG AND CIRCULATION, 2018, 27 (06): : 748 - 751
  • [37] Recommendations for Imaging Patients With Cardiac Implantable Electronic Devices (CIEDs)
    Vigen, Karl K.
    Reeder, Scott B.
    Hood, Maureen N.
    Steckner, Michael
    Leiner, Tim
    Dombroski, David A.
    Gulani, Vikas
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2021, 53 (05) : 1311 - 1317
  • [38] Cardiac MRI for Patients With Cardiac Implantable Electronic Devices
    Stojanovska, Jadranka
    Runge, Mason
    Mahani, Maryam Ghadimi
    Cronin, Paul P.
    Sayyouh, Mohamed
    Bogun, Frank
    Ibrahim, El-Sayed H.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2020, 215 (02) : 374 - 381
  • [39] Reducing cardiac implantable electronic device–induced artefacts in cardiac magnetic resonance imaging
    Aino-Maija Vuorinen
    Lauri Lehmonen
    Jarkko Karvonen
    Miia Holmström
    Sari Kivistö
    Touko Kaasalainen
    European Radiology, 2023, 33 : 1229 - 1242
  • [40] The safety of cardiac magnetic resonance imaging in patients with implantable cardiac devices compatible and non-compatible with MRI
    Rozmiarek, S.
    Rajewska-Tabor, J.
    Klotzka, A.
    Janus, M.
    Siniawski, A.
    Pyda, M.
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2019, 20 : 425 - 425