Recommendations for Imaging Patients With Cardiac Implantable Electronic Devices (CIEDs)

被引:13
|
作者
Vigen, Karl K. [1 ]
Reeder, Scott B. [1 ,2 ,3 ,4 ,5 ]
Hood, Maureen N. [6 ]
Steckner, Michael [7 ]
Leiner, Tim [8 ]
Dombroski, David A. [9 ]
Gulani, Vikas [10 ]
机构
[1] Univ Wisconsin, Dept Radiol, 1111 Highland Ave, Madison, WI 53705 USA
[2] Univ Wisconsin, Dept Med Phys, 1530 Med Sci Ctr, Madison, WI 53706 USA
[3] Univ Wisconsin, Dept Biomed Engn, Madison, WI USA
[4] Univ Wisconsin, Dept Med, Madison, WI USA
[5] Univ Wisconsin, Dept Emergency Med, Madison, WI USA
[6] Uniformed Serv Univ Hlth Sci, Dept Radiol & Radiol Sci, Bethesda, MD USA
[7] Canon Med Res USA, Mayfield Village, OH USA
[8] Utrecht Univ Med Ctr, Dept Radiol, Utrecht, Netherlands
[9] Univ Rochester, Med Ctr, Dept Radiol, Rochester, NY 14642 USA
[10] Univ Michigan, Dept Radiol, Ann Arbor, MI 48109 USA
关键词
magnetic resonance imaging safety; cardiac implantable electronic device; pacemakers; implantable cardioverter defibrillators; CONSENSUS STATEMENT; PACEMAKER; SAFETY; DEFIBRILLATORS; ASSOCIATION; SOCIETY; LEADS;
D O I
10.1002/jmri.27320
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Historically, the presence of cardiac implantable electronic devices (CIEDs), including pacemakers and implantable cardioverter defibrillators (ICDs), was widely considered an absolute contraindication to magnetic resonance imaging (MRI). The recent development of CIEDs with MR Conditional labeling, as well as encouraging results from retrospective studies and a prospective trial on the safety of MRI performed in patients with CIEDs without MR Conditional labeling, have led to a reevaluation of this practice. The purpose of this report is to provide a concise summary of recent developments, including practical guidelines that an institution could adopt for radiologists who choose to image patients with CIEDs that do not have MR Conditional labeling. This report was written on behalf of and approved by the International Society for Magnetic Resonance in Medicine (ISMRM) Safety Committee. Level of Evidence 3. Technical Efficacy Stage 1.
引用
收藏
页码:1311 / 1317
页数:7
相关论文
共 50 条
  • [1] Cardiac implantable electronic devices (CIEDs) and allergy
    De Ruvo, Ermenegildo
    Petrungaro, Mattia
    De Luca, Lucia
    Bressi, Edoardo
    Bruni, Giuseppe
    Fagagnini, Alessandro
    Grieco, Domenico
    Martino, Anna Maria
    Panuccio, Marco
    Politano, Alessandro
    Rebecchi, Marco
    Calo, Leonardo
    [J]. JOURNAL OF ARRHYTHMIA, 2023, 39 (03) : 310 - 314
  • [2] Australian radiographers' awareness of cardiac implantable electronic devices (CIEDs) in mammographic imaging
    Fitzgerald, J.
    Spuur, K.
    Singh, C.
    Hayre, C.
    Al Mousa, D. S.
    [J]. RADIOGRAPHY, 2023, 29 (05) : 984 - 991
  • [3] MR Imaging of Patients with Cardiac Implantable Electronic Devices (CIEDs): Implementing a Program and Optimizing CMR
    Gulhane A.
    Litt H.
    [J]. Current Radiology Reports, 6 (11)
  • [4] Percutaneous Extraction of Cardiac Implantable Electronic Devices (CIEDs) in Octogenarians
    Williams, Steven E.
    Arujuna, Aruna
    Whitaker, John
    Sohal, Manav
    Shetty, Anoop K.
    Roy, Debashis
    Bostock, Julian
    Cooklin, Michael
    Gill, Jaswinder
    O'Neill, Mark
    Wright, Matthew
    Patel, Nikhil
    Bucknall, Cliff
    Hamid, Shoaib
    Rinaldi, C. Aldo
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2012, 35 (07): : 841 - 849
  • [5] Provision of MR imaging for patients with cardiac implantable electronic devices (CIEDs): a single-center experience and national survey
    Murray, Aoife S.
    Gilligan, Paddy J.
    Bisset, James M.
    Nolan, Chris
    Galvin, Joseph M.
    Murray, John G.
    [J]. IRISH JOURNAL OF MEDICAL SCIENCE, 2019, 188 (03) : 999 - 1004
  • [6] Provision of MR imaging for patients with cardiac implantable electronic devices (CIEDs): a single-center experience and national survey
    Aoife S. Murray
    Paddy J. Gilligan
    James M. Bisset
    Chris Nolan
    Joseph M. Galvin
    John G. Murray
    [J]. Irish Journal of Medical Science (1971 -), 2019, 188 : 999 - 1004
  • [7] Synopsis of JBS recommendations for magnetic resonance imaging in patients with cardiac implantable electronic devices
    Zghaib, Tarek
    Nazarian, Saman
    [J]. HEART, 2024, 110 (04) : 225 - 227
  • [8] RECOMMENDATIONS FOR PERIOPERATIVE MANAGEMENT OF PATIENTS WITH CARDIAC IMPLANTABLE ELECTRONIC DEVICES
    Pavlovic, Nikola
    Manola, Sime
    Vrazic, Hrvoje
    Vucic, Marinko
    Brusich, Sandro
    Radeljic, Vjekoslav
    Zeljkovic, Ivan
    Matasic, Richard
    Anic, Ante
    Benko, Ivica
    Gavranovic, Zeljka
    Glogoski, Milana Zlatic
    [J]. ACTA CLINICA CROATICA, 2018, 57 (02) : 383 - 390
  • [9] Safety verification of carbon-ion radiotherapy for patients with cardiac implantable electronic devices (CIEDs)
    Okano, Naoko
    Sakai, Makoto
    Shibuya, Kei
    Tsuda, Kazuhisa
    Kanzaki, Takao
    Sano, Masato
    Kaneko, Yoshiaki
    Ohno, Tatsuya
    [J]. JOURNAL OF RADIATION RESEARCH, 2022, 63 (01) : 122 - 127
  • [10] Prediction of radiation-induced malfunction for cardiac implantable electronic devices (CIEDs)
    Matsubara, Hiroaki
    Ezura, Takatomo
    Hashimoto, Yaichiro
    Karasawa, Kumiko
    Nishio, Teiji
    Tsuneda, Masato
    [J]. MEDICAL PHYSICS, 2020, 47 (04) : 1489 - 1498