Multicenter retrospective evaluation of magnetic resonance imaging in pediatric and congenital heart disease patients with cardiac implantable electronic devices

被引:1
|
作者
Gakenheimer-Smith, Lindsey [1 ,16 ]
Ou, Zhining [2 ]
Kuang, Jinqiu [1 ]
Moore, Jeremy P. [3 ]
Burrows, Austin [3 ]
Kovach, Joshua [4 ]
Dechert, Brynn [5 ]
Beach, Cheyenne M. [6 ]
Ayers, Mark [7 ]
Tan, Reina Bianca [8 ]
Mostafavifar, Mina [9 ]
Mah, Douglas Y. [10 ]
Conner, Tracy Marrs [11 ]
Turpin, Susan [12 ]
Avasarala, Kishor [12 ]
Shah, Maully J. [13 ]
Webster, Gregory [14 ]
Posey, Jessica [15 ]
Etheridge, Susan P. [1 ]
Binka, Edem [1 ]
Niu, Mary [1 ]
Asaki, S. Yukiko [1 ]
Lambert, Linda M. [1 ]
Pilcher, Thomas A. [1 ]
机构
[1] Univ Utah, Dept Pediat, Div Pediat Cardiol, Salt Lake City, UT USA
[2] Univ Utah, Sch Med, Dept Internal Med, Div Epidemiol, Salt Lake City, UT USA
[3] UCLA, Med Ctr, Dept Pediat, Div Cardiol, Los Angeles, CA USA
[4] Med Coll Wisconsin, Dept Pediat, Div Pediat Cardiol, Milwaukee, WI USA
[5] Univ Michigan, Dept Pediat, Div Pediat Cardiol, Ann Arbor, MI USA
[6] Yale Univ, Sch Med, New Haven, CT USA
[7] Indiana Univ Sch Med, Dept Pediat, Div Pediat Cardiol, Indianapolis, IN USA
[8] NYU, Grossman Sch Med, Dept Pediat, Div Pediat Cardiol, New York, NY USA
[9] OHSU, Div Pediat Cardiol, Portland, OR USA
[10] Harvard Med Sch, Boston Childrens Hosp, Dept Cardiol, Boston, MA USA
[11] Washington Univ St Louis, Div Pediat Cardiol, St Louis, MO USA
[12] UCSF Benioff Childrens Hosp, Oakland, CA USA
[13] Univ Penn, Childrens Hosp Philadelphia, Philadelphia, PA USA
[14] Northwestern Univ, Ann & Robert H Lurie Childrens Hosp Chicago, Chicago, IL USA
[15] Childrens Healthcare Atlanta Cardiol, Atlanta, GA USA
[16] Univ Utah, Dept Pediat, 81 N Mario Capecchi Dr, Salt Lake City, UT 84113 USA
基金
美国国家卫生研究院;
关键词
Cardiac implantable electronic device; Epicardial lead; Abandoned lead; Magnetic resonance imaging; Congenital heart disease; Pediatrics; SAFETY; UTILITY; MRI;
D O I
10.1016/j.hrthm.2023.08.034
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Guidelines addressing magnetic resonance imaging (MRI) in patients with cardiac implantable electronic devices (CIEDs) provide algorithms for imaging pediatric and congenital heart disease (CHD) patients. Guideline acceptance varies by institution. Guidelines also do not support routine MRI scans in patients with epicardial or abandoned leads, common in pediatric and CHD patients.OBJECTIVE The purpose of this study was to determine the incidence of MRI-related complications in pediatric and CHD patients with CIEDs, including epicardial and/or abandoned leads.METHODS A multicenter retrospective review included patients with CIEDs who underwent any MRI between 2007 and 2022 atcongenital cardiac centers. The primary outcome was any patient adverse event or clinically significant CIED change after MRI, defined as pacing lead capture threshold increase >0.5 V with output change, P-or R-wave amplitude decrease >50% with sensitivity change, or impedance change >50%.RESULTS Across 14 institutions, 314 patients (median age 18.8 [1.3; 31.4] years) underwent 389 MRIs. There were 288 pacemakers (74%) and 87 implantable cardioverter-defibrillators (22%); 52% contained epicardial leads, and 14 (4%) were abandoned leads only. Symptoms or CIED changes occurred in 4.9% of MRI scans (6.1% of patients). On 9 occasions (2%), warmth or pain occurred. Pacing capture threshold or lead impedance changes occurred in 1.4% and 2.0% of CIEDs post-MRI and at follow-up.CONCLUSION Our data provide evidence that MRIs can be per-formed in pediatric and CHD patients with CIEDs, including non- MRI-conditional CIEDs and epicardial and/or abandoned leads, with rare minor symptoms or CIED changes but no other complications.
引用
收藏
页码:1752 / 1758
页数:7
相关论文
共 50 条
  • [1] Magnetic resonance imaging in patients with cardiac implantable electronic devices
    Maass, A. H.
    Hemels, M. E. W.
    Allaart, C. P.
    NETHERLANDS HEART JOURNAL, 2018, 26 (12) : 584 - 590
  • [2] Magnetic resonance imaging in patients with cardiac implantable electronic devices
    A. H. Maass
    M. E. W. Hemels
    C. P. Allaart
    Netherlands Heart Journal, 2018, 26 : 584 - 590
  • [3] Magnetic Resonance Imaging in Patients With Cardiac Implantable Electronic Devices
    Eyal, Allon
    Roguin, Ariel
    CIRCULATION, 2015, 132 (14) : E176 - E178
  • [4] Magnetic resonance imaging safety in patients with cardiac implantable electronic devices
    Yang, Eunice
    Suzuki, Masahito
    Nazarian, Saman
    Halperin, Henry R.
    TRENDS IN CARDIOVASCULAR MEDICINE, 2022, 32 (07) : 440 - 447
  • [5] The Safety of Cardiac and Thoracic Magnetic Resonance Imaging in Patients with Cardiac Implantable Electronic Devices
    Dandamudi, Sanjay
    Collins, Jeremy D.
    Carr, James C.
    Mongkolwat, Pat
    Rahsepar, Amir A.
    Tomson, Todd T.
    Verma, Nishant
    Arora, Rishi
    Chicos, Alex B.
    Kim, Susan S.
    Lin, Albert C.
    Passman, Rod S.
    Knight, Bradley P.
    ACADEMIC RADIOLOGY, 2016, 23 (12) : 1498 - 1505
  • [6] Safety and utility of magnetic resonance imaging in patients with cardiac implantable electronic devices
    Strom, Jordan B.
    Whelan, Jill B.
    Shen, Changyu
    Zheng, Shuang Qi
    Mortele, Koenraad J.
    Kramer, Daniel B.
    HEART RHYTHM, 2017, 14 (08) : 1138 - 1144
  • [7] Magnetic Resonance Imaging in Patients With Cardiac Implantable Electronic Devices With Abandoned Leads
    Schaller, Robert D.
    Brunker, Tamara
    Riley, Michael P.
    Marchlinski, Francis E.
    Nazarian, Saman
    Litt, Harold
    JAMA CARDIOLOGY, 2021, 6 (05) : 549 - 556
  • [8] Magnetic resonance imaging in patients with cardiac implantable electronic devices: A prospective study
    Navarro-Valverde, Cristina
    Ramos-Maqueda, Javier
    Jose Romero-Reyes, M.
    Esteve-Ruiz, Irene
    Garcia-Medina, Dolores
    Pavon-Jimenez, Ricardo
    Rodriguez-Gomez, Cristobal
    Leal-Del-Ojo, Juan
    Cayuela, Aurelio
    Molano-Casimiro, Francisco J.
    MAGNETIC RESONANCE IMAGING, 2022, 91 : 9 - 15
  • [9] Implantable Electronic Cardiac Devices and Compatibility With Magnetic Resonance Imaging
    Miller, Jared D.
    Nazarian, Saman
    Halperin, Henry R.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (14) : 1590 - 1598
  • [10] Magnetic Resonance Imaging in Patients With Implantable Cardiac Devices
    Sierra, Mark
    Machado, Christian