Safety and utility of magnetic resonance imaging in patients with cardiac implantable electronic devices

被引:35
|
作者
Strom, Jordan B. [1 ,2 ]
Whelan, Jill B. [2 ,3 ]
Shen, Changyu [1 ,2 ]
Zheng, Shuang Qi [2 ]
Mortele, Koenraad J. [4 ,5 ]
Kramer, Daniel B. [1 ,2 ]
机构
[1] Beth Israel Deaconess Med Ctr, Richard A & Susan F Smith Ctr Cardiovasc Outcomes, Div Cardiovasc Med, 375 Longwood Ave,Fourth Floor, Boston, MA 02215 USA
[2] Harvard Med Sch, Boston, MA USA
[3] Beth Israel Deaconess Med Ctr, Div Cardiovasc Med, Boston, MA 02215 USA
[4] Harvard Med Sch, Beth Israel Deaconess Med Ctr, Dept Radiol, Div Abdominal Imaging, Boston, MA USA
[5] Harvard Med Sch, Beth Israel Deaconess Med Ctr, Dept Radiol, Div Body MRI, Boston, MA USA
关键词
magnetic resonance imaging; Cardiac pacemakers; Implantable cardioverter-defibrillators; CARDIOVERTER-DEFIBRILLATOR PATIENTS; PACEMAKER-DEPENDENT PATIENTS; INDUSTRY VIEWPOINT; 1.5; TESLA; PERMANENT PACEMAKERS; ABANDONED PACEMAKER; MRI; LEADS; ICDS; ASSOCIATION;
D O I
10.1016/j.hrthm.2017.03.039
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Off-label magnetic resonance imaging (MRI) for patients with cardiac implantable electrical devices has been limited owing to concerns about safety and unclear diagnostic and prognostic utility. OBJECTIVE The purpose of this study was to define major and minor adverse events with off-label MRI scans. METHODS We prospectively evaluated patients with non-MRIconditional cardiac implantable electrical devices referred for MRI scans under a strict clinical protocol. The primary safety outcome was incidence of major adverse events (loss of pacing, inappropriate shock or antitachycardia pacing, need for system revision, or death) or minor adverse events (inappropriate pacing, arrhythmias, poweron-reset events, heating at the generator site, or changes in device parameters at baseline or at 6 months). RESULTS A total of 189 MRI scans were performed in 123 patients (63.1% [78] men; median age 70 +/- 18.5 years; 56.9% [70] patients with implantable cardioverter-defibrillators; 33.3% [41] pacemaker-dependent patients) predominantly for brain or spinal conditions. A minority of scans (22.7% [43]) were performed for urgent or emergent indications. Major adverse events were rare: 1 patient with loss of pacing, no deaths, or system revisions (overall rate 0.5%; 95% confidence interval 0.01-2.91). Minor adverse events were similarly rare (overall rate 1.6%; 95% confidence interval 0.3-4.6). Nearly all studies (98.4% [186]) were interpretable, while 75.1% [142] were determined to change management according to the prespecified criteria. No clinically significant changes were observed in device parameters acutely after MRI or at 6 months as compared with baseline across all patient and device categories. CONCLUSION Off-label MRI scans performed under a strict protocol demonstrated excellent short-and medium-term safety while providing interpretable imaging that frequently influenced clinical care.
引用
收藏
页码:1138 / 1144
页数:7
相关论文
共 50 条
  • [1] Magnetic resonance imaging safety in patients with cardiac implantable electronic devices
    Yang, Eunice
    Suzuki, Masahito
    Nazarian, Saman
    Halperin, Henry R.
    [J]. TRENDS IN CARDIOVASCULAR MEDICINE, 2022, 32 (07) : 440 - 447
  • [2] The Safety of Cardiac and Thoracic Magnetic Resonance Imaging in Patients with Cardiac Implantable Electronic Devices
    Dandamudi, Sanjay
    Collins, Jeremy D.
    Carr, James C.
    Mongkolwat, Pat
    Rahsepar, Amir A.
    Tomson, Todd T.
    Verma, Nishant
    Arora, Rishi
    Chicos, Alex B.
    Kim, Susan S.
    Lin, Albert C.
    Passman, Rod S.
    Knight, Bradley P.
    [J]. ACADEMIC RADIOLOGY, 2016, 23 (12) : 1498 - 1505
  • [3] Magnetic resonance imaging in patients with cardiac implantable electronic devices
    Maass, A. H.
    Hemels, M. E. W.
    Allaart, C. P.
    [J]. NETHERLANDS HEART JOURNAL, 2018, 26 (12) : 584 - 590
  • [4] Magnetic resonance imaging in patients with cardiac implantable electronic devices
    A. H. Maass
    M. E. W. Hemels
    C. P. Allaart
    [J]. Netherlands Heart Journal, 2018, 26 : 584 - 590
  • [5] Magnetic Resonance Imaging in Patients With Cardiac Implantable Electronic Devices
    Eyal, Allon
    Roguin, Ariel
    [J]. CIRCULATION, 2015, 132 (14) : E176 - E178
  • [6] SAFETY OF CARDIAC MAGNETIC RESONANCE IMAGING WITH NON-CONDITIONAL CARDIAC IMPLANTABLE ELECTRONIC DEVICES
    Eyvazian, Vaughn
    Do, Duc H.
    Bayoneta, Aileen Joy
    Finn, J.
    Boyle, Noel
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 69 (11) : 429 - 429
  • [7] Magnetic Resonance Imaging in Patients With Cardiac Implantable Electronic Devices With Abandoned Leads
    Schaller, Robert D.
    Brunker, Tamara
    Riley, Michael P.
    Marchlinski, Francis E.
    Nazarian, Saman
    Litt, Harold
    [J]. JAMA CARDIOLOGY, 2021, 6 (05) : 549 - 556
  • [8] Magnetic resonance imaging in patients with cardiac implantable electronic devices: A prospective study
    Navarro-Valverde, Cristina
    Ramos-Maqueda, Javier
    Jose Romero-Reyes, M.
    Esteve-Ruiz, Irene
    Garcia-Medina, Dolores
    Pavon-Jimenez, Ricardo
    Rodriguez-Gomez, Cristobal
    Leal-Del-Ojo, Juan
    Cayuela, Aurelio
    Molano-Casimiro, Francisco J.
    [J]. MAGNETIC RESONANCE IMAGING, 2022, 91 : 9 - 15
  • [9] Implantable Electronic Cardiac Devices and Compatibility With Magnetic Resonance Imaging
    Miller, Jared D.
    Nazarian, Saman
    Halperin, Henry R.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (14) : 1590 - 1598
  • [10] Magnetic Resonance Imaging in Patients With Implantable Cardiac Devices
    Sierra, Mark
    Machado, Christian
    [J]. REVIEWS IN CARDIOVASCULAR MEDICINE, 2008, 9 (04) : 232 - 238