Thermal interference of adjacent legs in a vertical U-tube heat exchanger for a ground-coupled heat pump

被引:0
|
作者
Muraya, NK
ONeal, DL
Heffington, WM
机构
来源
关键词
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A transient finite-element model of the heat transfer around a vertical U-tube heat exchanger for a ground-coupled heat pump was developed to study the thermal interference that occurs between the adjacent legs of the U-tube. Parametric studies examined performance on two-dimensional horizontal cross sections as a function of soil properties (temperature, thermal conductivity, and diffusivity), separation distance of the legs, diameter of the tubes, and imposed wall surface temperatures. Thermal interference was quantified by defining a heat exchanger effectiveness. This value was the ratio of the heat transfer form the two legs of the U-tube in the heat exchanger to the heat transfer from the two legs if they were each in an infinite medium. The impacts of separation distance, leg temperatures, different ambient soil temperatures, and backfills were all investigated. The effectiveness had to be modified to account properly for backfills. Results with different source and ambient temperatures were nondimensionalized into a single plot. Effectiveness results were most sensitive to separation distance and backfill thermal conductivity.
引用
收藏
页码:12 / 21
页数:10
相关论文
共 50 条
  • [41] Study on Thermal Resistance of Coaxial Tube Boreholes in Ground-Coupled Heat Pump Systems
    Fang, Liang
    Diao, Nairen
    Shao, Zhukun
    Wang, Zuotao
    Fang, Zhaohong
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 3735 - 3742
  • [42] Borehole thermal resistance of U-tube borehole heat exchanger
    Abuel-Naga, H. M.
    Al-Chalabi, R. R.
    GEOTECHNIQUE LETTERS, 2016, 6 (04) : 250 - 255
  • [43] Experimental investigation of thermal storage in U-tube heat exchanger
    Cakmak, Gulsah
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2013, 44 : 83 - 86
  • [44] Performance evaluation of a vertical U-tube ground heat exchanger using a numerical simulation approach
    Hu, Pingfang
    Yu, Zhongyi
    Lei, Fei
    Zhu, Na
    Sun, Qiming
    Yuan, Xudong
    APPLIED ENERGY TECHNOLOGY, PTS 1 AND 2, 2013, 724-725 : 909 - +
  • [45] Numerical simulation analysis on vertical U-tube underground heat exchanger
    Lian, Xiaoxin
    Liu, Jinxiang
    Chen, Xiaochun
    Li, Ying
    Ding, Gao
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2012, 33 (01): : 48 - 55
  • [46] CFD numerical simulation of a U-tube ground heat exchanger used in ground source heat pumps
    Mechanical Engineering School, University of Science and Technology Beijing, Beijing 100083, China
    Beijing Keji Daxue Xuebao, 2007, 3 (329-333): : 329 - 333
  • [47] A new constant heat flux model for vertical U-tube ground heat exchangers
    Li, Zhongjian
    ENERGY AND BUILDINGS, 2012, 45 : 311 - 316
  • [48] Transient heat transfer in a U-tube borehole heat exchanger
    Beier, Richard A.
    APPLIED THERMAL ENGINEERING, 2014, 62 (01) : 256 - 266
  • [49] Soil temperature affected by heat exchanger when ground-coupled source heat pump running
    Zhou Zhi-hua
    Zhang Zhi-hong
    Liu Xiao-hai
    Zhang Shi-hua
    JOURNAL OF CENTRAL SOUTH UNIVERSITY OF TECHNOLOGY, 2007, 14 : 202 - 204
  • [50] Performance of Conventional and Innovative Single U-Tube Pipe Configuration in Vertical Ground Heat Exchanger (VGHE)
    Eswiasi, Adel
    Mukhopadhyaya, Phalguni
    SUSTAINABILITY, 2021, 13 (11)