Thermal interference of adjacent legs in a vertical U-tube heat exchanger for a ground-coupled heat pump

被引:0
|
作者
Muraya, NK
ONeal, DL
Heffington, WM
机构
来源
关键词
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A transient finite-element model of the heat transfer around a vertical U-tube heat exchanger for a ground-coupled heat pump was developed to study the thermal interference that occurs between the adjacent legs of the U-tube. Parametric studies examined performance on two-dimensional horizontal cross sections as a function of soil properties (temperature, thermal conductivity, and diffusivity), separation distance of the legs, diameter of the tubes, and imposed wall surface temperatures. Thermal interference was quantified by defining a heat exchanger effectiveness. This value was the ratio of the heat transfer form the two legs of the U-tube in the heat exchanger to the heat transfer from the two legs if they were each in an infinite medium. The impacts of separation distance, leg temperatures, different ambient soil temperatures, and backfills were all investigated. The effectiveness had to be modified to account properly for backfills. Results with different source and ambient temperatures were nondimensionalized into a single plot. Effectiveness results were most sensitive to separation distance and backfill thermal conductivity.
引用
收藏
页码:12 / 21
页数:10
相关论文
共 50 条
  • [21] Numerical simulation and experimental validation of a vertical U-tube ground heat exchanger
    Gao, Yike
    Gao, Yan
    Yu, Yong
    Lin, Xinxing
    ENERGY DEVELOPMENT, PTS 1-4, 2014, 860-863 : 709 - +
  • [22] Ground-coupled heat pump system with a buried underfloor heat exchanger
    Den Braven, Karen R.
    Drown, David C.
    American Society of Mechanical Engineers, Advanced Energy Systems Division (Publication) AES, 1992, 28 : 97 - 101
  • [23] Numerical Analysis of the Factors Influencing a Vertical U-Tube Ground Heat Exchanger
    Chen, Shangyuan
    Mao, Jinfeng
    Han, Xu
    Li, Chaofeng
    Liu, Liyao
    SUSTAINABILITY, 2016, 8 (09):
  • [24] Heat extraction characteristics of a vertical U-tube downhole heat exchanger
    Department of Mechanical Engineering, Akita University, 1-1 Tegatagakuen-cho, Akita-shi, Akita, 010-8502, Japan
    Nihon Kikai Gakkai Ronbunshu, B, 2008, 5 (1145-1153): : 1145 - 1153
  • [25] A Study on the Thermal Performance of Vertical U-Tube Ground Heat Exchangers
    Zheng, Zonghe
    Wang, Weixiao
    Ji, Chao
    PROCEEDINGS OF INTERNATIONAL CONFERENCE ON SMART GRID AND CLEAN ENERGY TECHNOLOGIES (ICSGCE 2011), 2011, 12
  • [26] Optimization and Analysis of a Vertical Ground-Coupled Heat Pump
    Kord, Ali Siavoshi
    Jazayeri, Seyed Ali
    INTERNATIONAL JOURNAL OF RENEWABLE ENERGY RESEARCH, 2012, 2 (01): : 33 - 37
  • [27] An Improved Thermal-Resistance-Capacitance Model for Vertical Single U-Tube Ground Heat Exchanger
    Liao, Quan
    Fan, Yongxiang
    Zhu, Xiaobo
    Li, Jintang
    JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2019, 11 (01)
  • [28] Analysis of thermal and dynamic comportment of a geothermal vertical U-tube heat exchanger
    Bouhacina, Benamar
    Saim, Rachid
    Benzenine, Hamidou
    Oztop, Hakan F.
    ENERGY AND BUILDINGS, 2013, 58 : 37 - 43
  • [29] Thermal performance of a single U-tube ground heat exchanger: A parametric study
    Mousavi Ajarostaghi, Seyed Soheil
    Javadi, Hossein
    Mousavi, Seyed Sina
    Poncet, Sebastien
    Pourfallah, Mohsen
    JOURNAL OF CENTRAL SOUTH UNIVERSITY, 2021, 28 (11) : 3580 - 3598
  • [30] EFFECTIVE BOREHOLE THERMAL RESISTANCE OF A SINGLE U-TUBE GROUND HEAT EXCHANGER
    Liao, Quan
    Zhou, Chao
    Cui, Wenzhi
    Jen, Tien-Chien
    NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 2012, 62 (03) : 197 - 210