Thermal interference of adjacent legs in a vertical U-tube heat exchanger for a ground-coupled heat pump

被引:0
|
作者
Muraya, NK
ONeal, DL
Heffington, WM
机构
来源
关键词
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A transient finite-element model of the heat transfer around a vertical U-tube heat exchanger for a ground-coupled heat pump was developed to study the thermal interference that occurs between the adjacent legs of the U-tube. Parametric studies examined performance on two-dimensional horizontal cross sections as a function of soil properties (temperature, thermal conductivity, and diffusivity), separation distance of the legs, diameter of the tubes, and imposed wall surface temperatures. Thermal interference was quantified by defining a heat exchanger effectiveness. This value was the ratio of the heat transfer form the two legs of the U-tube in the heat exchanger to the heat transfer from the two legs if they were each in an infinite medium. The impacts of separation distance, leg temperatures, different ambient soil temperatures, and backfills were all investigated. The effectiveness had to be modified to account properly for backfills. Results with different source and ambient temperatures were nondimensionalized into a single plot. Effectiveness results were most sensitive to separation distance and backfill thermal conductivity.
引用
收藏
页码:12 / 21
页数:10
相关论文
共 50 条
  • [31] Unified heat transfer model of vertical U-tube heat exchangers for ground source heat pump system
    Zhang, Z.-W. (zwzhang10@126.com), 1600, Tsinghua University (31):
  • [32] Numerical Simulation of Soil Temperature Field Surrounding Vertical U Tube Heat Exchanger for Ground Coupled Heat Pump
    Bai, Tian
    Zhang, Jianli
    Zheng, Maoyu
    Zhang, Hui
    He, Maoting
    PROCEEDINGS OF THE SECOND INTERNATIONAL CONFERENCE ON MODELLING AND SIMULATION (ICMS2009), VOL 3, 2009, : 275 - 280
  • [33] Thermal-economic modeling and optimization of vertical ground-coupled heat pump
    Sanaye, Sepehr
    Niroomand, Behzad
    ENERGY CONVERSION AND MANAGEMENT, 2009, 50 (04) : 1136 - 1147
  • [34] Computer simulation of the U-tube ground heat exchanger for GSHP
    Key Laboratory-Enhanced Heat Transfer and Energy Conservation, College of Environmental and Energy Engineering, Beijing University of Technology, Beijing 100022, China
    不详
    Beijing Gongye Daxue Xuebao J. Beijing Univ. Technol., 2006, 1 (62-66):
  • [35] Bond graph model of a vertical U-tube steam condenser coupled with a heat exchanger
    Medjaher, K.
    Samantaray, A. K.
    Bouamama, B. Ould
    SIMULATION MODELLING PRACTICE AND THEORY, 2009, 17 (01) : 228 - 239
  • [36] Cumulated energy consumption in a heat pump system using a U-tube ground heat exchanger in a moderate climate
    Remiorz, Leszek
    Hanuszkiewicz-Drapala, Malgorzata
    ENERGY AND BUILDINGS, 2015, 96 : 118 - 127
  • [38] Effect of buried depth on thermal performance of a vertical U-tube underground heat exchanger
    Yang, Li
    Zhang, Bo
    Klemes, Jiri Jaromir
    Liu, Jie
    Song, Meiyu
    Wang, Jin
    OPEN PHYSICS, 2021, 19 (01): : 327 - 330
  • [39] Study of Thermal Inertia in the Subsoil Adjacent to a Civil Engineering Laboratory for a Ground-Coupled Heat Exchanger
    Gutierrez-Duran, Raul Antonio
    Cervantes, Luciano. A.
    Lopez, Dagoberto Lopez
    Peralta-Jaramillo, Juan
    Delgado-Plaza, Emerita
    Abril-Macias, Guido
    Limon-Leyva, Pablo
    Sosa-Tinoco, Ian
    ENERGIES, 2023, 16 (23)
  • [40] VERTICAL CONCENTRIC TUBE GROUND-COUPLED HEAT-EXCHANGERS
    MEI, V
    FISCHER, S
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1983, 25 (05): : 59 - 59